Table of Contents

Advertisement

Installation manual
R32 Split series
3MXM40N2V1B
3MXM52N2V1B
3AMXM52M3V1B
3MXM68N2V1B
3AMXF52A2V1B
3MXF52A2V1B
3MXF68A2V1B
4MXM68N2V1B
Installation manual
4MXM80N2V1B
English
R32 Split series
5MXM90N2V1B

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 3MXF52A2V1B and is the answer not in the manual?

Questions and answers

Summarization of Contents

About the documentation
1.1 About this document
Overview of the manual's content and purpose.
Target audience and installer qualifications
Defines who should use the manual and stresses the need for qualified installers.
Documentation set and reference resources
Details the components of the documentation set and points to digital resources.
About the box
2.1 Outdoor unit accessories
Lists and describes accessories included with the outdoor unit.
Preparation
3.1 Preparing the installation site
Guidelines for selecting an appropriate installation location for the outdoor unit.
3.1.3 Refrigerant piping length and height difference
Details maximum allowable refrigerant piping lengths and height differences.
Installation
4.1 Mounting the outdoor unit
Instructions for securely mounting the outdoor unit on a structure.
4.2 Connecting the refrigerant piping
Steps for connecting refrigerant pipes between units, including reducer usage.
4.3 Checking the refrigerant piping
Procedures for leak checking and vacuum drying the refrigerant system.
4.4 Charging refrigerant
Guidance on charging the system with refrigerant, including calculating amounts.
4.5 Connecting the electrical wiring
Steps for connecting electrical wiring between indoor and outdoor units.
4.6 Finishing the outdoor unit installation
Covers final steps like insulating piping and installing the service cover.
4.6.2 Standby electricity saving function
Explains and how to enable the standby electricity saving feature.
4.6.3 Priority room function
Describes and how to set the priority room function for specific indoor units.
4.6.4 Night quiet mode
Explains the night quiet mode for reduced nighttime noise.
4.6.5 Heat mode lock
Describes how to limit operation to heating mode only.
4.6.6 Cool mode lock
Explains how to limit operation to cooling mode only.
Commissioning
5.1 Checklist before commissioning
A pre-operation checklist to ensure proper installation before powering up.
5.2 Checklist during commissioning
Items to check during the commissioning process.
5.3 Trial operation and testing
Procedures for test running the unit and verifying its operation.
5.3.1 Wiring error check
Details on performing a wiring error check and its implications.
5.4 Starting up the outdoor unit
Instructions for starting up the outdoor unit as part of system commissioning.
Disposal
6.1 To pump down
Instructions on how to safely pump down the refrigerant system.
6.2 To start and stop forced cooling
Procedures for starting and stopping forced cooling operation.
Technical data
7.1 Wiring diagram
Provides diagrams and legends for electrical connections.
7.1.1 Unified wiring diagram legend
Explains symbols used in the wiring diagrams.
7.2 Piping diagram: Outdoor unit
Illustrates the refrigerant piping layout for outdoor units.

Table of Contents