Sign In
Upload
Download
Table of Contents
Contents
Add to my manuals
Delete from my manuals
Share
URL of this page:
HTML Link:
Bookmark this page
Add
Manual will be automatically added to "My Manuals"
Print this page
×
Bookmark added
×
Added to my manuals
Manuals
Brands
ABB Manuals
Power distribution unit
RELION REM611
Modbus point list manual
ABB RELION REM611 Modbus Point List Manual
Motor protection and control
Hide thumbs
1
2
3
4
5
6
Table Of Contents
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
page
of
60
Go
/
60
Contents
Table of Contents
Bookmarks
Table of Contents
Table of Contents
Section 1 Introduction
This Manual
Intended Audience
Product Documentation
Product Documentation Set
Document Revision History
Related Documentation
Symbols and Conventions
Symbols
Document Conventions
Functions, Codes and Symbols
Section 2 Modbus Data Mappings
Overview
Supported Functions in REM611
Indications
Premapped Indications
Common Data 1
CTRL.CBCILO1 Circuit Breaker Enable Signals (1)
CTRL.CBCSWI1 Circuit Breaker (1) Mom. Position
CTRL.CBCSWI1 Circuit Breaker (1) Mom+MCD Position
CTRL.CBXCBR1 Circuit-Breaker Control (1)
LD0.CCBRBRF1 Circuit Breaker Failure Protection (1)
LD0.CMMXU1 Three-Phase Current Measurement (1)
LD0.EFHPTOC1 Non-Directional Earth-Fault Protection, High Stage (1)
LD0.EFLPTOC1 Non-Directional Earth-Fault Protection Low Stage (1)
LD0.ESMGAPC1 Emergency Start-Up (1)
LD0.JAMPTOC1 Motor Load Jam Protection (1)
LD0.LEDGGIO1 Indication LED States Color1/Color2
LD0.LEDGGIO1 Indication LED States Off/Colorx
LD0.LEDPTRC1 Global Conditioning (1)
LD0.LEDPTRC1 Global Conditioning - Phase Information (1)
LD0.LOFLPTUC1 Loss of Load Supervision (1)
LD0.MDSOPT1 Runtime Counter for Machines and Devices (1)
LD0.MNSPTOC1 Negative-Sequence Overcurrent Protection for Machines (1)
LD0.MNSPTOC2 Negative-Sequence Overcurrent Protection for Machines (2)
LD0.MPTTR1 Thermal Overload Protection for Motors (1)
LD0.MVGAPC1 Move (8 Pcs) (1)
LD0.PHIPTOC1 Three-Phase Non-Directional Overcurrent Protection, Instantaneous Stage (1)
LD0.PHLPTOC1 Three-Phase Non-Directional Overcurrent Protection, Low Stage (1)
LD0.PREVPTOC1 Phase Reversal Protection (1)
LD0.RESCMMXU1 Residual Current Measurement (1)
LD0.STTPMSU1 Motor Start-Up Supervision (1)
LD0.TCSSCBR1 Trip Circuit Supervision (1)
LD0.TCSSCBR2 Trip Circuit Supervision (2)
LD0.TRPPTRC1 Master Trip (1)
LD0.TRPPTRC2 Master Trip (2)
LD0.XGGIO100 Physical I/O States (PSM Card X100)
LD0.XGGIO120 Physical I/O States (AIM Card X120)
Unmapped Indications
All Premapped Three-Phase Protection Function Stages, Start and Operate/Phase-Dependent Objects Added
Common Data 2
DR.RDRE1 Disturbance Recorder Signals
LD0.IL1TCTR1 Three-Phase CT Supervision (1)
LD0.RCHLCCH1 Ethernet Supervision (1)
LD0.RESTCTR1 Io CT Supervision (1)
Registers
Premapped Registers
Active Parameter Setting Group Read and Write
Control Structure 1
Control Structure 2
Control Structure 3
Control Structure 4
Control Structure 5
Control Structure 6
Control Structure 7
Control Structure 8
Device ID String
Event Record Structure
Fault Record Structure Header
Fault Record Data
IED Real-Time Clock (in Local Time Mode), Read and Write (Synchronize)
IED Real-Time Clock (in UTC Time Mode), Read and Write (Synchronize)
Indication Bits Mirrored in Registers
SSR1 System Status Register (1) Device Health
SSR2 System Status Register (2) Protection Relay's Mode and State
SSR3 System Status Register (3) Data Available 1 (Client-Dependent)
SSR4 System Status Register (4) Data Available 2 (Client-Dependent, User-Definable)
SSR5 System Status Register (5) Device Alive Register
SSR6 System Status Register (6) Control Command Status (Client-Dependent)
System Register Values
Time and Reason for Latest IED Reset
User-Definable Bits [Alt.2], Visible on 0X,1X,3X and 4X
User-Definable Registers [Alt.1], Visible on 3X and 4X
CTRL.CBCSWI1 Circuit Breaker Operation Counter (1)
LD0.CMMXU1 Phase Current Demand Values (1)
LD0.CMMXU1 Three-Phase Current Measurement (1)
LD0.CSMSQI1 Sequence Current Measurement (1)
LD0.MDSOPT1 Runtime Counter for Machines and Devices (1)
LD0.MPTTR1 Thermal Overload Protection for Motors (1)
LD0.RESCMMXU1 Residual Current Demand Value (1)
LD0.RESCMMXU1 Residual Current Measurement (1)
Unmapped Registers
CTRL.LLN0 Local, Remote, Station, off and Combinations
Controls
Reset, Acknowledge and Trigger Points
CTRL.CBCSWI1 Circuit Breaker Control (1)
LD0.LDEV1 Protection Relay's Warm Reset (1)
Unmapped Control Points
Section 3 Glossary
Advertisement
Quick Links
Download this manual
See also:
Installation Manual
,
Modbus Point List Manual
—
RELION® 611 SERIES
Motor Protection and Control
REM611
Modbus Point List Manual
Table of
Contents
Previous
Page
Next
Page
1
2
3
4
5
Advertisement
Table of Contents
Need help?
Do you have a question about the RELION REM611 and is the answer not in the manual?
Ask a question
Questions and answers
Related Manuals for ABB RELION REM611
Power distribution unit ABB RED670 Product Manual
Line differential protection ansi customized, relion 670 series (119 pages)
Power distribution unit ABB RED670 Product Manual
Line differential protection, pre-configured, relion 670 series (101 pages)
Power distribution unit ABB RET670 Commissioning Manual
Transformer protection version 2.1 ansi (254 pages)
Power distribution unit ABB RELION 650 Series Applications Manual
Transformer protection version 2.1 (288 pages)
Power distribution unit ABB Relion 650 Series Product Manual
Transformer protection (72 pages)
Power distribution unit ABB RELION REB500 Product Manual
Distributed busbar protection version 8.3 iec (55 pages)
Power distribution unit ABB REQ650 Commissioning Manual
Relion 650 series, breaker protection (148 pages)
Power distribution unit ABB Relion Applications Manual
Voltage protection and control (84 pages)
Power distribution unit ABB 650 Series Engineering Manual
Relion protection and control (130 pages)
Power distribution unit ABB Relion 670 Series Quick Start Manual
Version 2.2 ansi (48 pages)
Power distribution unit ABB RER670 Commissioning Manual
Relion 670 series, railway application version 2.2 iec (216 pages)
Power distribution unit ABB REJ603 Product Manual
Self-powered feeder protection, relion 605 series (24 pages)
Power distribution unit ABB Relion 630 Series Engineering Manual
(156 pages)
Power distribution unit ABB RELION REX640 Installation Manual
(100 pages)
Power distribution unit ABB RELION REX640 Engineering Manual
Protection and control (156 pages)
Power distribution unit ABB REL650 ANSI Commissioning Manual
Line distance protection ansi (186 pages)
Summarization of Contents
Section 1 Introduction
This manual
Describes the purpose and scope of the point list manual.
Intended audience
Identifies the target readers and necessary knowledge for this manual.
Product documentation
Lists related documents and their intended use throughout product lifecycles.
Document revision history
Details the changes made to the document across different versions.
Related documentation
Lists other relevant manuals and documents for the product.
Symbols and conventions
Explains the meaning of symbols, icons, and document conventions used.
Functions, codes and symbols
Details the protection functions, their codes, and related symbols.
Section 2 Modbus data mappings
Overview
Describes the scope and applicability of Modbus data points and structures.
Supported functions in REM611
Lists the Modbus-supported functions available in the REM611 device.
Indications
Explains the structure of indication tables and provides column definitions.
Premapped indications
Details specific common data points and indications mapped to Modbus.
Registers
Introduces the section detailing Modbus registers and their explanations.
Premapped registers
Details common registers and specific register mappings for the device.
System status registers
Covers various system status registers (SSR1-SSR6) for device health and state.
System register values and resets
Details system register values and information on IED reset events.
User-definable data
Covers user-definable bits and registers available for configuration.
Unmapped registers and controls
Explains unmapped registers and control points and their configuration.
Controls
Introduces control functions, including reset, acknowledge, and specific command points.
Section 3 Glossary
Table of Contents
Print
Rename the bookmark
Delete bookmark?
Delete from my manuals?
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL
Need help?
Do you have a question about the RELION REM611 and is the answer not in the manual?
Questions and answers