Checking Gas Connections - Desa CFS18NRA Owner's Operation And Installation Manual

Desa owner's operation and installation manual unvented (vent-free) natural gas log heater cfs18nra, vs18nra ,vs24nra, vs30nra
Table of Contents

Advertisement

DESA INTERNATIONAL
UNVENTED NATURAL GAS LOG HEATER
INSTALLATION
Continued
CHECKING GAS
CONNECTIONS
WARNING: Test all gas pip-
ing and connections for leaks
after installing or servicing. Cor-
rect all leaks at once.
WARNING: Never use an open
flame to check for a leak. Apply a
mixture of liquid soap and water
to all joints. Bubbles forming show
a leak. Correct all leaks at once.
Pressure Testing gas Supply
Piping system
Test Pressures In Excess Of 1/2 PSIG
1. Disconnect heater and its individual
manual shutoff valve from gas supply
piping system. Pressures in excess of
1/2 psig will damage heater regulator.
2. Cap off open end of gas pipe where
manual shutoff valve was connected.
3. Pressurize supply piping system by ei-
ther using compressed air or opening
main gas valve located on or near gas
meter.
4. Check all joints of gas supply piping
system. Apply mixture of liquid soap
and water to gas joints. Bubbles form-
ing show a leak.
5. Correct all leaks at once.
6. Reconnect heater and manual shutoff
valve to gas supply. Check reconnected
fittings for leaks.
Test Pressures Equal To or Less Than
1/2 PSIG
1.
Close manual shutoff valve (see Fig-
ure 14).
2.
Pressurize supply piping system by either
using compressed air or opening main gas
valve located on or near gas meter.
3.
Check all joints from gas meter to manual
shutoff valve (see Figure 15). Apply mix-
ture of liquid soap and water to gas joints.
Bubbles forming show a leak.
4.
Correct all leaks at once.
Manual
Shutoff
Valve
Figure 14 - Manual Shutoff Valve
Manual Shutoff Valve
Gas Meter
Figure 15 - Checking Gas Joints
12
Pressure Testing Heater Gas
Connections
1.
Open manual shutoff valve (see Fig-
ure 14).
2.
Open main gas valve located on or near
gas meter.
3.
Make sure control knob of heater is in
the OFF position.
4.
Check all joints from manual shutoff
valve to gas control (see Figure 15).
Apply mixture of liquid soap and wa-
ter to gas joints. Bubbles forming show
a leak.
Open
ON
POSIT
5.
Correct all leaks at once.
6.
Light heater (see Operating Heater,
pages 14 through 16). Check all other
internal joints for leaks.
O
7.
Turn off heater (see To Turn Off Gas to
Closed
POS
Appliance, page 15).