USER'S MANUAL
Mode: ZS82
Mode: ZS52
Mode: SZ32
Firma Handlowa Wena
A
l. Jerozolimskie 311
05-816 Reguły, Poland
tel. +48 22 8370286; +48 22 8174008
Mode: ZS10
Mode: ZS30
Mode: ZS50
e-mail:
biuro@vidos.pl
www.vidos.pl
W.20190906ENG

Advertisement

loading
Need help?

Need help?

Do you have a question about the ZS50 and is the answer not in the manual?

Questions and answers

Summary of Contents for Vidos ZS50

  • Page 1 USER’S MANUAL Mode: ZS82 Mode: ZS52 Mode: SZ32 Firma Handlowa Wena l. Jerozolimskie 311 05-816 Reguły, Poland tel. +48 22 8370286; +48 22 8174008 Mode: ZS10 Mode: ZS30 Mode: ZS50 e-mail: biuro@vidos.pl www.vidos.pl W.20190906ENG...
  • Page 2 Wiring Diagram Red-power DC input +12V - +24V Black-power AC input ~ 12V - 24V Brown-door status detecting Orange-unlocking button 1 Yellow-unlocking button 2 Working conditions: Green-GND temperature: -20C ~ +50C RH: 95% Blue-NO 2 Current and voltage requirements: Purple-COM 2 DC input: +12V - +24V AC input: ~ 12V - 24V...
  • Page 3 Matrix keypads Working conditions: temperature: -20C ~ +50C Current and voltage requirements: Working conditions: DC input: +12V - +24V temperature: -20C ~ +50C AC input: ~ 12V - 24V standby current: 80mA Current and voltage requirements: working current: 110mA DC input: +12V - +24V Applicable card mode: AC input: ~ 12V - 24V...
  • Page 4 Mode indicator Case screw Touch keypads Antenna Working conditions: temperature: -20C ~ +50C Working conditions: temperature: -20C ~ +50C Current and voltage requirements: DC input: +12V - +24V Current and voltage requirements: AC input: ~ 12V - 24V DC input: +12V - +24V standby current: 80mA...
  • Page 5 NOTICE Working conditions: temperature: -20C ~ +50C Attention items of disassembly Current and voltage requirements: (ZS10/ZS30) DC input: +12V - +24V AC input: ~ 12V - 24V 1. Please remove the cover carefully following the manual. Not standby current: 80mA permitted to remove with sudden force.
  • Page 6 Applicable mode: ZS10//30/50/ Applicable mode: ZS32 Find a suitable location to mount the keypad. Then please operate Before installation, position the location where the controller unit is it according to the following steps. mounted. Please operate it according to the following steps: 1.
  • Page 7 1. ZONE 1 and 2 relays can be programmed for opening the lock, up to 1000 user cards and correlative codes can be stored into ZONE 1, 10 Applicable mode: ZS52/82 user cards or codes can be stored into ZONE 2 . In addition, ZONE 1...
  • Page 8 Delete the user card and code(ZONE 1) Set the length of passwords In the setting mode: In the setting mode: Enter one set number(3 digits) from 000 to 999 data storage units, Press the button and yellow LED indicator will be flashing, then i f red LED indicator is on, means there is data stored in this set of unit, press press the button and a sound "BI"...
  • Page 9 Set the unlocking time for ZONE 1 A. When ZONE 1 relay actived, door indicator will turn green. In the setting mode: B. When ZONE 2 relay actived, door indicator will turn red. Press the button , the mode indicator will flash yellow, enter the number from 00 to 99, the mode indicator will turn yellow in In case forget thea dminc ode,p resst heb utton a ndh oldo n,t hen...
  • Page 10 Turn on/off the door bell Group cards added in ZONE 1 In the setting mode: In the setting mode: Press the button (mode indicator will flash yellow), follow Press the button , the yellow LED indicator will be flashing, with the , a long beep will be heard whilst the mode indicator then press the button , a sound "BI"...
  • Page 11: Warranty Card

    8. The condition to perform repair works is to deliver the Product with the Warranty Card and the proof of purchase. 9. Service Centre: Firma Handlowa Wena Al. Jerozolimskie 311 , 05 - 816 Reguły / near Warsaw Poland tel. +48 228 370 286; +48 228 174 003 e-mail: biuro@vidos.pl www.vidos.pl - 20 - - 19 -...