Take Measurements; All Units - Viking RDIPR101RSS Use & Care Information Manual

D3 downdraft ventilators
Hide thumbs Also See for RDIPR101RSS:
Table of Contents

Advertisement

Available languages

Available languages

viking range corporation
pLanning
Interior Blower Installation
This downdraft blower system is
designed to be used to exhaust
airborne contaminants when
cooking with a variety of gas
or electric cooktops. It can be
mounted in island, peninsula,
or conventional wall locations.
This unit can be easily installed
following these basic steps:
• Cut out the countertop
opening.
• Mount the unit in the cabi-
net.
• Install the Model VIDV500
Interior Blower
• Connect the ductwork and
electrical.
• Install the cooktop.
note: the high level of air flow
of this appliance may effect the
gas flame on some types of gas
cooktops. This is NORMAL and
will cause no harm, but can be
corrected by lowering the speed
of the blower.

take MeaSUreMentS

1. Refer to the cooktop installation instructions for dimensions
of cooktop, countertop cut-out, and cabinet requirements.
The Model RDIPR101RSS will fit in most 30" wide cabinets,
the Model RDIPR161RSS will fit in most 36" wide cabinets,
and the Model RDIPR151RSS will fit most 45" wide cabinets.
However, it is recommended that oversized cabinets be used
for easier installation.
2. Cooktop depth can vary greatly from one to another. This may
cause the fit of these two appliances to be rather tight.
Pay special attention to the areas of potential interference high-
lighted above. A countertop with (A) a raised lip and/or (B) a
backsplash may not allow enough flat countertop for a proper
installation. Note that 2" of flat countertop is required behind
cooktop and that 1-3/4" is necessary between the back edge of
the cooktop and the inside of cabinet back.
tYpicaL inStaLLation
CHIMNEY TOP
COUNTER
TOP
COOK TOP
AIR
VENT
GEAR
MOTOR
COVER
BLOWER
BOX
120 VAC
GROUNDED
OUTLET
3-1/4" X 10"
DUCT CONNECTOR
eLectricaL
SpeciFicationS
120 VAC • 60 Hz • 4.0 A
Exterior Blower Installation
This downdraft blower system
is designed to be used to ex-
haust airborne contaminants
when cooking with a variety
of gas or electric cooktops.
It can be mounted in island,
peninsula, or conventional wall
locations.
This unit can be easily installed
following these basic steps:
• Cut out the countertop
opening.
• Mount the unit in the
cabinet.
• Install 10" round dis-
charge plate
• Install Model VEDV900 or
VEDV1200
External Blower
only)
• Connect the ductwork
and electrical.
• Install the cooktop.
note: the high level of air flow of this appliance may effect the
gas flame on some types of gas cooktops. This is NORMAL and
will cause no harm, but can be corrected by lowering the speed
of the blower.

All Units

2
D3 Downdraft Ventilators
tYpicaL inStaLLation
COUNTER TOP
COOK TOP
GEARMOTOR
COVER
10" ROUND
DISCHARGE
PLATE
10" ROUND DUCTWORK
(DIPR151RSS
eLectricaL
SpeciFicationS
120 VAC • 60 Hz • 6.0 A (max.)
CHIMNEY TOP
AIR
VENT
120 VAC
GROUNDED
OUTLET

Hide quick links:

Advertisement

Table of Contents
loading