Propane Supply; Installation - Desa 30LP Owner's Manual

Propane construction heater
Table of Contents

Advertisement

30,000 BTU/Hr
PROPANE CONSTRUCTION HEATER
ASSEMBLY
1. Remove screw from top of fan guard.
Discard screw.
2. Insert nut clip (provided with handle)
with flat side facing up through slot in
top of shell. Align holes in nut clip with
screw hole behind slot in top of shell.
(see Figure 4).
3. Place handle over hole and clip. In-
sert two screws (provided with handle)
through handle and tighten into shell.
Make sure rear screw goes through
shell and into fan guard. Tighten
screws firmly.
Figure 3 - Removing Screw from Top of
Fan Guard
Flat Side Facing Up
Slot
Figure 4 - Installing Nut Clip
Nut Clip
Figure 5 - Attaching Handle

PROPANE SUPPLY

Propane gas and propane tank(s) are to be
furnished by the user.
Use this heater only with a propane vapor
withdrawal supply system. See Chapter 5 of
the Standard for Storage and Handling of
Liquefied Petroleum Gas, ANSI/NFPA 58
and/or CAN/CGA B149.2. Your local library
or fire department will have this booklet.
The amount of propane gas ready for use
from propane tanks varies. Two factors de-
cide this amount:
1.
The amount of propane gas in tank(s)
2.
The temperature of tank(s)
Remove
This heater is designed to operate with a
Screw
minimum 20-pound propane tank. You may
need two or more tanks or one larger tank in
colder weather. Use a 100-pound tank for
longer operation or in very cold weather.
Less gas is vaporized at lower temperatures.
Your local propane gas dealer will help you
select the proper supply system. The mini-
mum surrounding air temperature rating for
each heater is -20 F (-29 C).
Average Temp ( F)
Nut Clip
At Tank Location
Shell

INSTALLATION

derstand the warnings in the
Screws
Safety Information section, page
2. They are needed to safely op-
erate this heater. Follow all local
codes when using this heater.
Handle
Rear of
ing and connections for leaks
Heater
after installation or servicing.
Never use an open flame to check
for a leak. Apply a mixture of
liquid soap and water to all joints.
Bubbles forming show a leak.
Correct all leaks at once.
No. Of Tanks
(100-pound)
40
32
20
10
0
-10
-20
WARNING: Review and un-
WARNING: Test all gas pip-
4
1.
Provide propane supply system (see
Propane Supply).
2.
Connect POL fitting on hose/regulator
assembly to propane tank(s). Turn POL
fitting counterclockwise into threads on
tank. Tighten firmly using wrench.
IMPORTANT: Position regulator so
that hose leaving the regulator is in a
horizontal position (see Figure 6). This
places the regulator vent in the proper
position to protect it from the weather.
3.
Connect hose to valve inlet (see Figure
7). Tighten firmly using a wrench.
IMPORTANT: Use extra hose or pip-
ing if needed. Install extra hose or pip-
ing between hose/regulator assembly
and propane tank. You must use the
regulator supplied with heater.
4.
Open propane supply valve on propane
tank(s) slowly. Note: If not opened
slowly, excess-flow check valve on pro-
pane tank will stop gas flow. You may
hear a click from the excess-flow check
valve closing. If this happens, reset the
excess-flow check valve by closing pro-
pane supply valve and open again slowly.
5.
Check all connections for leaks. Apply
mixture of liquid soap and water to gas
joints. Bubbles forming show a leak
1
that must be corrected.
1
1
6.
Close propane supply valve.
1
1
Propane Supply
2
Valve
2
Propane
Tank
Figure 6 - Regulator Position
Figure 7 - Hose and Inlet Connector
Regulator
Hose
POL Fitting
104163