  • Page 1 Touch Expert USER MANUAL July 2017, QS4 436 v.8...
  • Page 3 Sd-580 / Sd-575 / Sd-550 / Sd-350 / Sd-300 34991 Dental Unit Sd-300 Scandinavian / Sd-80 / Sd-80 Scandinavian We, the undersigned, under our sole responsibility, certify and declare that the medical device specified above is in conformity with the essential requirements, which are applicable to them, of...
  • Page 5: Table Of Contents

    User’s Manual Touch Expert Contents Use cautions Introduction 1. How to use the interface 1.1 Buttons and sliding bars 1.2 Alphanumeric keyboard 1.3 Information windows 1.4 Pull-down window 2. Main screen 2.1 Overview 2.2 How to operate 2.3 Area 1: General fields 2.4 Area 2: Dental chair motion 2.5 Area 3: Dental unit auxiliary functions 2.6 Chronometer...
  • Page 6 Touch Expert User’s Manual 5. Turbine screen 5.1 Overview 5.2 How to operate 5.3 Area 1: General fields 5.4 Area 2: Turbine programming functions 5.5 Area 3: Turbine speed display 5.6 Area 4: Turbine Light control 5.7 Area 5: Dental unit auxiliary functions 6.
  • Page 7 Manual de usuario Touch Expert 9. Technical configuration screen 9.1 Overview 9.2 How to operate 9.3 Area 1: Instruments configuration 9.4 Area 2: Timeout settings and exit 10. Instruments advanced adjustment screen 10.1 Overview 10.2 Micromotor adjustment screen: 10.2.1 Overview 10.2.2 Area 1: Instrument configuration 10.2.3 Area 2: Exit button 10.3 Turbine / scaler adjustment screen:...
  • Page 8: Use Cautions

    Touch Expert User’s Manual Use cautions - Read and understand this manual before starting to use of the dental unit. - Keep this manual in a safe place for future consulta- tion during all the life of the equipment. - Never manipulate the touch panel surface with sharp objects.
  • Page 9: Introduction

    User’s Manual Touch Expert Introduction We are grateful to you for your purchase of any the dental unit Ancar Sd-80 / Sd-300 / Sd-350 / Sd-550 / Sd-575. This Instructions Manual contains information about the Touch Expert control interface and it is a complement of the information supplied in the user’s manual of the dental unit in what refers to con-...
  • Page 10: How To Use The Interface

    Touch Expert User’s Manual How to use the interface 1.1 Buttons and sliding bars 1.2 Alphanumeric keyboard 1.3 Information windows 1.4 Pull-down window...
  • Page 11 User’s Manual Touch Expert Different items can be seen in the screen: Active buttons: Having light background, this type of buttons performs an action when pressed. Pressed buttons: When an active button is pressed, it is enclosed by an orange frame. A button with an orange frame indicates that its function is active.
  • Page 12 Touch Expert User’s Manual It pops up to enter a numeric or alphanumeric value. The keyboard is divided in two areas. Value limits Item under edition For numerical This window shows values, this window the symbol or text shows the limits of describing the item under edition.
  • Page 13 User’s Manual Touch Expert Those windows usually appear in actions that require confirmation. They also show error messages. Confirmation window. Shows important information that needs to be read with confirmation. Confirm / cancel window. To confirm or cancel actions that will change the configuration of the equipment.
  • Page 14 Touch Expert User’s Manual It pops up to select an item of a predefined list. This type of window is applied to buttons such as Doctor’s name, micromotor’s contra-angle or language. In the alphanumerical keyboard, Alphanumeric keys have also the values out of limits are automati- following special characters: cally changed by the closest limit...
  • Page 15: Main Screen

    User’s Manual Touch Expert Main screen 2.1 Overview 2.2 How to operate 2.3 Area 1: General fields 2.4 Area 2: Dental chair motion 2.5 Area 3: Dental unit auxiliary functions 2.6 Chronometer...
  • Page 16: Area 2: Dental Chair Motion

    Touch Expert User’s Manual The main screen appears when all instruments are in the instruments tray. In this screen you can adjust the position of the chair and use func- tions of glass and basin water, dental unit light, an auxiliary free function and the access to the configuration menus.
  • Page 17 User’s Manual Touch Expert Upper right hand corner contains general information about Cordless pedal operation and is common to the rest of screens. Wireless signal coverage icon It informs about quality of communication in between transmitter and receiver electronic cards. As separation from pedal to dental unit increases, level of coverage will decrease, but within a dental cabinet, distances are not a determining factor.
  • Page 18 Touch Expert User’s Manual It contains general information and is common to the rest of screens. Screen lock button If you keep the top right-hand corner pressed you lock the screen and the figure of a padlock appears in the middle. You can reactivate it again by pressing it again for a few seconds.
  • Page 19 User’s Manual Touch Expert It contains the controls for chair movements. Home position Memory buttons button Those buttons move the chair to preset positions. To program a posi- Moves the chair to tion move the chair with the arrow the home position to buttons and then press one of the allow the patient to memory buttons for about 2 seconds,...
  • Page 20 Touch Expert User’s Manual It contains auxiliary functions of the dental unit. This area is common with the rest of user’s screens. Glass water button It activates the glass and basin water at the same time (configurable). A fast Adjustment Dental unit touch activates the water light button...
  • Page 21 User’s Manual Touch Expert The Chronometer function activates a user’s programmed countdown. The chronometer window is normally hidden. To open it, press for about 2 seconds the Time button located in the general fields area (see section 2.3 Area 1: General fields). The chronometer window will appear in the upper side of the screen.
  • Page 22: Chronometer

    Touch Expert User’s Manual The chronometer is shown in the left side of the window. It works always in countdown mode and it stops when reaching 0. In this window, the following functions are available: Chronometer button ESC button This button is active only when the It closes the chronometer is stopped.
  • Page 23 User’s Manual Touch Expert With the Doctor’s name button Pressing OK saves the new you can select up to 4 different settings in the general memory, users, each of them having its common for all doctors. own settings and statistics. In the “Glass Button”, simultane- To program a chair position and ous activation of glass and basin...
  • Page 24: Micromotor Screen

    Touch Expert User’s Manual Micromotor screen 3.1 Overview 3.2 How to operate 3.3 Area 1: General fields 3.4 Area 2: Micromotor’s programming functions 3.5 Area 3: Micromotor’s speed control 3.6 Area 4: Micromotor’s Light control 3.7 Area 5: Dental unit auxiliary functions...
  • Page 25 User’s Manual Touch Expert This screen appears when a It is possible to save the adjust- micromotor is in use. It allows ments on the screen for future the adjustment of the working sessions. parameters such as speed, rota- tion, use of water, light and the You may assign micromotor at contra-angle.
  • Page 26 Touch Expert User’s Manual It contains general information and is common to the rest of screens. See chapter 2 of this manual. It contains the following controls: Recording parameters of the last working session It is possible to leave all the parameters of the last active working session in the memory if parameter 45 (chapter 11) has been set to record them automatically (value “1”) for each instrument position.
  • Page 27 User’s Manual Touch Expert It contains the speed controls of the micromotor. Max RPM button With the pedal off, displays the maximum speed value to which the tool will turn. With the pedal on, displays the actual tool’s speed value. To change Max RPM, press the button and enter the new value in the numeric keyboard.
  • Page 28 Touch Expert User’s Manual It contains auxiliary controls of the dental unit. This area is common with the rest of user’s screens. Described in chap- ter 2 of this manual. Note that the Adjustment menus button is passive, so the function is disabled. Adjustment menus button In this screen, the...
  • Page 29: Mx Micromotor Screen

    User’s Manual Touch Expert MX micromotor screen 4.1 Overview 4.2 How to operate 4.3 Area 1: General fields 4.4 Area 2: MX programming functions 4.5 Area 3: MX speed control 4.6 Area 4: MX torque control 4.7 Area 5: MX Light control 4.8 Area 6: Dental unit auxiliary functions...
  • Page 30 Touch Expert User’s Manual This screen appears when a MX2 is completed (ENDO). generic MX micromotor is in use. What makes them different is The dental unit allows up to 2 that basic model only works in installed (it is up to you to decide OPERATIVE mode.
  • Page 31 User’s Manual Touch Expert It contains general information and is common to the rest of screens. See chapter 2 of this manual. It contains the following controls: MX program button Press this button to open a selection window with a list of predefined MX programs.
  • Page 32 Touch Expert User’s Manual It contains the following controls: Recording parameters of the last working session It is possible to leave all the parameters of the last active working session in the memory if parameter 45 (chapter 11) has been set for the position occupied by the instrument.
  • Page 33 User’s Manual Touch Expert It contains the speed controls of the MX micromotor. Max RPM button With the pedal off, displays the maximum speed value to which the tool will turn. With the pedal on, displays the actual tool’s speed value.
  • Page 34 Touch Expert User’s Manual It contains the controls for the instrument’s light. Illumination adjustment bar Light ON/OFF button This bar display the illumination Switches the light on level of the instrument’s light. and off. Press and drag the bar to adjust illumination level in an easy and intuitive way.
  • Page 35 User’s Manual Touch Expert With the Doctor’s name button you The dental unit has a default can select up to 4 different users, contra-angle’s table. To modify each of them having its own set- that table, please contact to you tings and statistics.
  • Page 36: Turbine Screen

    Touch Expert User’s Manual Turbine screen 5.1 Overview 5.2 How to operate 5.3 Area 1: General fields 5.4 Area 2: Turbine programming functions 5.5 Area 3: Turbine speed display 5.6 Area 4: Turbine Light control 5.7 Area 5: Dental unit auxiliary functions...
  • Page 37: Area 2: Turbine Programming Functions

    User’s Manual Touch Expert This screen appears when a It is possible to save the adjust- turbine is in use. It allows the ments on the screen for future adjustment of its working param- sessions. eters such as speed mode, use of water and light.
  • Page 38 Touch Expert User’s Manual It contains general information and is common to the rest of screens. See chapter 2 of this manual. It contains the following controls: Secret button Constant speed button Although it looks pas- Disables the progressive sive, press it for about pedal and makes the 2 seconds to save in turbine to turn always to...
  • Page 39 User’s Manual Touch Expert It contains the display elements to visualize the turning speed of the turbine. Speed display bar This bar is passive and visualizes the speed to which the tool is turning. The indication is given in % of the maximum speed.
  • Page 40 Touch Expert User’s Manual It contains auxiliary controls of the dental unit. This area is com- mon with the rest of user’s screens. Described in chapter 2 of this manual. Note that the Adjustment menus button is passive, so the function is disabled. Adjustment menus button In this screen,...
  • Page 41: Area 5: Dental Unit Auxiliary Functions

    User’s Manual Touch Expert Scaler 6.1 Overview 6.2 How to operate 6.3 Area 1: General fields 6.4 Area 2: Scaler programming functions 6.5 Area 3: Scaler speed display 6.6 Area 4: Scaler Light control 6.7 Area 5: Dental unit auxiliary functions...
  • Page 42: Area 5: Dental Unit Auxiliary Functions

    Touch Expert User’s Manual This screen appears when the ul- It is possible to save the adjust- trasounds instrument is in use. It ments on the screen for future allows the adjustment of its work- sessions. ing parameters such as power, working range, and light.
  • Page 43 User’s Manual Touch Expert It contains general information and is common to the rest of screens. See chapter 2 of this manual. It contains the following controls: Recording parameters of the last working session It is possible to leave all the parameters of the last active working session in the memory if parameter 45 (chapter 11) has been set for the position occupied by the instrument.
  • Page 44 Touch Expert User’s Manual It contains the power controls for the scaler. Power button Power adjustment bar Is passive and indicates This bar visualizes the power to which the the % of the total power ultrasounds will work. Press and drag the that is being applied.
  • Page 45 User’s Manual Touch Expert It contains auxiliary controls of the dental unit. This area is com- mon with the rest of user’s screens. Described in chapter 2 of this manual. Note that the Adjustment menus button is passive, so the function is disabled. Adjustment menus button In this screen, the button...
  • Page 46: General Configuration Screen

    Touch Expert User’s Manual General configuration screen 7.1 Overview 7.2 How to operate 7.3 Area 1: Fields of Name of centre, date and time 7.4 Area 2: Doctor’s fields 7.5 Area 3: Language field and exit button...
  • Page 47 User’s Manual Touch Expert This is a configuration screen. Press To enter in it, all the instruments must be restored to the instru- ments tray. It allows entering or modifying parameters such as name of the centre, date, time and names of to go to this screen from the main the doctors using the dental unit, screen.
  • Page 48 Touch Expert User’s Manual It contains the following fields: Name of the centre Use it to enter or modify the name of the centre. - Press the button. The alphanumeric keyboard will pop up. - Enter the name of the centre and press ENTER.
  • Page 49 User’s Manual Touch Expert It contains the following fields: Number of doctor button This is just informative and indicates the memory number of the data in its right. Doctor’s enable button Doctor’s name buttons Enables or disables the Use them to enter or corresponding memory modify the name of the number to include it in the...
  • Page 50 Touch Expert User’s Manual It contains the following fields: Language button Use it to change the language. - Press the button. A list of available languages will pop up. - Press on the desired language. Exit button Press this button to go back to the previous screen.
  • Page 51: Statistics Screen

    User’s Manual Touch Expert Statistics screen 8.1 Overview 8.2 How to operate 8.3 Area 1: Statistics selection 8.4 Area 2: Counters 8.4.1 Counters for Movements of the chair 8.4.2 Counters for Use of Instruments 8.4.3 List of Frequent Warnings 8.4.4 List of Recent Warnings 8.5 Area 3: Exit and partial counter reset buttons...
  • Page 52 Touch Expert User’s Manual In this screen you can see the to go to this screen from the main statistics of use of the unit for screen. every doctor. The option “All” per- mits to see the global statistics of the unit.
  • Page 53 User’s Manual Touch Expert It contains the Statistics selection button. This button allows selection among four different types of statistical information: Movements of the chair, Use of Instruments, Frequent Warn- ings and Recent Warnings. Statistics selection button It selects the type of statistical informa- tion to be shown.
  • Page 54 Touch Expert User’s Manual This window contains the information to look up. There are four different types: Movements of the chair, Use of Instruments, Frequent Warnings and Recent Warnings. Doctor’s name button Selects the name of the doctor from who you want to see the statistics.
  • Page 55 User’s Manual Touch Expert It contains the following fields: Doctor’s name button Selects the name of the doctor from who you want to see the statistics. To select a doctor’s name: - Press the button. A selection window with all the doctors available pops up.
  • Page 56 Touch Expert User’s Manual It contains the following fields: List of warnings window This window contains the list of the most frequent warnings, sorted by number of occurrences. There could be more than one page, depending on the number of different errors occurred. To change page use the Page forward button, described here below.
  • Page 57 User’s Manual Touch Expert It contains the following fields: List of warnings window This window contains the list of the most recent warnings, sorted by date and time of the occurrence. There could be more than one page, depending on the number of different errors occurred. To change page use the Page forward button, described here below.
  • Page 58 Touch Expert User’s Manual It contains the following buttons: Partial counter reset button Reset all partial counters. - Press the button. A confirm/cancel window will pop up. - Press OK. Exit button Press this button to go back to the previous screen. In the windows of Movements of the chair and Use of Instruments, select “All”...
  • Page 59: Technical Configuration Screen

    User’s Manual Touch Expert Technical configuration screen 9.1 Overview 9.2 How to operate 9.3 Area 1: Instruments configuration 9.4 Area 2: Timeout settings and exit...
  • Page 60 Touch Expert User’s Manual WARNING! This screen is protected with a password. Enter in it only when indicated by the authorized technical service and carefully following their instructions. A wrong operation in this screen may result in a missconfiguration of the unit, letting it out of order. This screen allows assigning an instrument to each of the 4 configurable positions of the...
  • Page 61: Area 2: Timeout Settings And Exit

    User’s Manual Touch Expert The screen is divided in two different areas: Area 1: Instruments con- figuration Area 2: Timeout settings and exit NOTE: Micromotor MX type The drop-down menu shows as first option Micromotor MX1 or MXB1, once you have selected one, for the second instrument offers MX2 or MXB2.
  • Page 62 Touch Expert User’s Manual It contains the following buttons: Advanced adjust- ments button Press it for advanced Number of instrument button adjustments of the This is just informative and indi- corresponding instrument. cates the position in the instru- See next chapter “10. ments tray.
  • Page 63 User’s Manual Touch Expert It contains the following buttons: Basin water time adjustment button It allows the modification of the basin water activation timeout. To do so: - Press the button. The numeric keyboard will pop up. - Enter a new value. Be careful with the limits.
  • Page 64 Touch Expert User’s Manual Enter in this screen only when already assigned to the rest of indicated by the authorized techni- positions. cal service and carefully following their instructions. A wrong opera- New values will be stored in tion in this screen may result in memory automatically, without a missconfiguration of the unit, confirmation.
  • Page 65: Instruments Advanced Adjustment Screen

    User’s Manual Touch Expert Instruments advanced adjustment screen 10.1 Overview 10.2 Micromotor adjustment screen : 10.2.1 Overview 10.2.2 Area 1: Instruments configuration 10.2.3 Area 2: Exit button 10.3 Turbine/scaler adjustment screen: 10.3.1 Overview 10.3.2 Area 1: Instruments configuration 10.3.3 Area 2: Exit button 10.4 Micromotor MX adjustment screen: 10.4.1 Overview 10.4.2 Area 1: Instrument identification and Light...
  • Page 66 Touch Expert User’s Manual WARNING! This screen permits to modify the instrument’s configuration. Enter in it only when indicated by the authorized technical service and carefully following their instructions. A wrong operation in this screen may result in a missconfiguration of the unit, letting it out of order. In this screen it is possible to adjust different parameters of the instruments, such as lamp voltage...
  • Page 67 User’s Manual Touch Expert The screen is divided in two different areas: Area 1: Instruments configuration Area 2: Exit button...
  • Page 68 Touch Expert User’s Manual It contains the following buttons: Instrument identification fields They identify the type of instrument and its position in the instruments tray. They are only informative. Lamp’s maximum voltage adjustment button This button is present only if the micromotor has a Light.
  • Page 69 User’s Manual Touch Expert It contains the following: Exit button Press this button to go back to the previous screen. The screen is divided in two different areas: Area 1: Instruments con- figuration Area 2: Exit button...
  • Page 70 Touch Expert User’s Manual It contains the following buttons: Instrument identification fields They identify the type of instrument and its position in the instruments tray. They are only informative. Lamp’s maximum voltage adjustment button This button is present only if the micromotor has a Light.
  • Page 71 User’s Manual Touch Expert This screen is divided in 4 different areas: Area 1: Instrument identifica- tion and Light adjustments Area 2: Endo mode adjust- ments Area 3: Warning adjustments Area 4: Advanced adjust- ments and exit...
  • Page 72 Touch Expert User’s Manual It contains the following: Instrument identification fields They identify the type of instrument and its position in the instruments tray. They are only informative. Endo mode Light button Use it to enable or disable automatic light on of the instru- ment’s light in Endo mode.
  • Page 73 User’s Manual Touch Expert It contains the following: Auto Reverse/ Auto Forward button Use it to select automatic forward or auto- matic reverse of the tool. Press the button to change between auto- matic forward (Auto forward) and automatic reverse (Auto reverse). Auto forward delay adjustment button Allows programming of the delay for the...
  • Page 74 Touch Expert User’s Manual Use it to enable / disable the acoustic warnings for the following functions: - Reverse rotation of the micromotor. Warning consists of 3 short consecutive beeps. - Reverse Endo activation. Warning consists of a continuous beep. - Error.
  • Page 75 User’s Manual Touch Expert It contains the following: System info button It opens an information window containing the software version of the micromotor MX control. Exit button Press this button to go back to the previous screen. Memory reset button It restores the factory settings of the micromo- tor MX.
  • Page 76: Advance Configuration Parameters Screen

    Touch Expert User’s Manual Advanced configuration parameters screen 11.1 Overview 11.2 How to operate 11.3 Area 1: Parameters configuration 11.4 Area 2: Exit button...
  • Page 77 User’s Manual Touch Expert WARNING! This screen is protected with a password. Enter in it only when indicated by the authorized technical service and carefully following their instructions. A wrong operation in this screen may result in a missconfiguration of the unit, letting it out of order. In this screen, it is possible to edit a list of advanced configuration parameters for especial functions...
  • Page 78 Touch Expert User’s Manual This screen is divided in 2 different areas: Area 1: Parameters configura- tion Area 2: Exit button...
  • Page 79 User’s Manual Touch Expert It contains the following: Parameter’s number button It contains the number of the parameter whose value is shown in the parameter’s value button. To change it: - Press the button. The numeric keyboard will pop up. - Enter a new value.
  • Page 80 Touch Expert User’s Manual The table following shows the list of the parameters and their values: Parameter’s number Function Value First number of the 0 a 255. relation for Contra- Disables that contra- angle 2. angle and all the following. Example: If value is 1, the relation of the contra-angle...
  • Page 81 User’s Manual Touch Expert Parameter’s number Function Value Foot pedal configuration 0 = Default value for the chair backrest Reverses the control direction respecting to the control direction existing one when value is 0. 0 = Regulates screen power 43.5 Ultrasound regulation (graphic scale) by means of display or...
  • Page 82 Touch Expert User’s Manual Parameter’s number Function Value 47.1 Automatic Chip Blower 0 = Option disabled from functionality per Doctor. dropdown list. 47.2 Possibility to remove Default value. 47.3 “only water” and / or e.g. 47.6 = “0”: indicates that 47.4 “only air”...
  • Page 83 User’s Manual Touch Expert Parameter’s number Function Value Instrument cleaning Default value, disabled cycle. function. It can be defined from 1 up to 255 seconds, then it will be showed on display auto-rinse program.
  • Page 84: Auto-Rinse Function

    Touch Expert User’s Manual Auto-rinse function WARNING This function shall only be available on electronic equipment whose software releases of keyboard and main PCBs are C3.19 and TP3.10, or later versions. The lower part of the “Autotest” screen show us the version of the equipment’s software.
  • Page 85 Touch Expert User’s Manual ACTIVATION Press the advanced settings menu button (parameters) Entering parameter 53 (in the upper box) will allow us to adjust the duration (in the lower box), up to a maximum of 255 s. Function is deactivated with default value of “0”. Once enabled function, icon will be showed on configuration menu.
  • Page 86 User’s Manual Touch Expert List of codes for errors and warnings WARNING! Most of the actions recommended in this chapter require the inter- vention of the authorized technical service. Proceed only with their expressed authorization and carefully following their instructions. WARNING! Always switch off the unit and plug it out from the mains before ma- nipulating the inside of the instrument.
  • Page 87 Touch Expert User’s Manual When there is a wrong manipulation of the unit or a function- ing error. The screen shows an information window with the corresponding error code. The following table shows the list of codes, their meaning and the actions to be taken: Error num- Explanation Actions...
  • Page 88 User’s Manual Touch Expert Error num- Explanation Actions Short-circuit in micro- Problem 1: motor or cables in the Cable from board to micromotor has a 1st position. Short-circuit. Solution: Check the connector of the cable. Check that cable is not dam- aged, cut or bent.
  • Page 89 Touch Expert User’s Manual Error num- Explanation Actions Bad or missing bulb in Same as before. the instrument of the 2nd position. Bad or missing bulb in Same as before. the instrument of the 3rd position. Bad or missing bulb in Same as before.
  • Page 90 User’s Manual Touch Expert Error num- Explanation Actions Assistant arm safety Problem: Activation of the assistant arm safety switch. Solution 1: move the arm to the right position. Solution 2: Check safety micro switch or/and cable. Initial test Error 1 Problem: micromotor source.
  • Page 91 Touch Expert User’s Manual Error num- Explanation Actions Error in the communi- Problem 1: cation Bus: bad supply Communication Bus is blocked due to or bad communication interferences or bad functioning. cables. Solution: Switch off the unit for about 5 seconds and switch it on again.
  • Page 92 User’s Manual Touch Expert Error num- Explanation Actions Solution: Check if there is a short-cir- cuit in the communications cables (pins 4, 5 and 6) of 9015130 board (colibrí), 9015043 board (hydric group), 9015092 board (connections box) and 9015127 board (pedal) (pins 3, 4 and 5). Problem 6: Communication cable fails.
  • Page 93 Touch Expert User’s Manual Error num- Explanation Actions Initial test error: Problem 1: hydric group does Wrong connection of the communi- not work, failure in cation’s cable (pins 4, 5 and 6) with the communication’s 9015043 board (hydric group). cable or micro. Solution: Check order of connections of the communication’s cable (pins 3, 4...
  • Page 94 User’s Manual Touch Expert Error num- Explanation Actions Solution: Check condition of connec- tions of the communication’s cable (pins 4, 5 and 6) with the 9015092 board (connections box) and 9015043 board (hydric group). Problem 3: Micro does not respond. Solution 1: Check supply of 9015092 board (connections box).
  • Page 95 Touch Expert User’s Manual Error num- Explanation Actions Failure in the 24VAC Problem: line. 24VAC line fails due to a short-circuit or an excess of charge. Solution 1: Check if there is a short- circuit or an excess of charge in the 24VAC line (pins 1 and 3) of the interconnection cable.
  • Page 96 User’s Manual Touch Expert Error num- Explanation Actions Touch screen does Problem 1: not communicate Failure of the cable between Touch with colibrí module, Expert keyboard and 9015130 board failure of the (colibrí). keyboard cable or failure of the colibrí Solution: Check condition of the cable microcontroller.
  • Page 97 Touch Expert User’s Manual Error num- Explanation Actions Failure of commu- Problem 1: nication with MX DMX cable failure. Driver. Solution: Check connection of DMX cable. Problem 2: DMX module failure. Solution: Change DMX module. Error in the detec- Problem: tion of MX Driver.
  • Page 98: Calibration Of Screen

    User’s Manual Touch Expert Calibration of Screen Adjustment of image and its centering is available when you switch on device and maintain pressure holding down at any point on screen. It will appear an information message that centering of image procedure is going to start, and that its performed by direct confirmation pressing on screen.
  • Page 99: Touch Expert Technical Specifications

    Touch Expert User’s Manual Touch Expert Technical specification Display Screen size: 7” colour, WVGA Resolution: 800 x 480 pixels Active area: 152.4 mm (hihg) x 91.44 mm (wide) Surface with anti-glare coating Touch panel Activation force: 130g Durability: 1,000.000 operations Light transmission: 80%...
  • Page 102 Volta dels Garrofers, 41-42 Polígono Industrial “Els Garrofers” July 2017 08340 Vilassar de Mar (Barcelona-SPAIN) Tel. (34) 93 754 07 97 Fax (34) 93 759 26 04 Subject to design and/or specification changes www.ancar-online.com / e-mail: ancar@ancar-online.com without prior warning. Made in Europe.