Assemb ly an d Op er ati n g M an u a l
SLIGHTLINE,
Exhaust air unit
SL 6030 ... E1...
SL 9030 ... E1...
SL 9040 ... E1...
SL 12040 ... E1...
English
www.ruck.eu

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SL 12040 E1 10 10 and is the answer not in the manual?

Questions and answers

Summary of Contents for Ruck SL 12040 E1 10 10

  • Page 1 Assemb ly an d Op er ati n g M an u a l SLIGHTLINE, Exhaust air unit SL 6030 ... E1... SL 9030 ... E1... SL 9040 ... E1... SL 12040 ... E1... English www.ruck.eu...
  • Page 2 This document, as well as the data, specifications and other information set forth in it, are the exclusive property of ruck Ventilatoren GmbH. It may not be reproduced or given to third parties without its consent.
  • Page 3: Table Of Contents

    11. Expansion and reconfiguration ............13 12. Dismantling and disposal ..............14 12.1. Disassembling the product ............14 12.2. Disposal ..................14 13. Troubleshooting ..................14 13.1. Possible operating faults .............. 14 14. Technical data ..................15 15. Wiring diagrams ..................15 www.ruck.eu...
  • Page 4: Important Information

    Children must be kept away from the product! 2.1. Intended use The ruck fan is a component in terms of the machine directive 2006/42/EC (partly completed ma- chinery). The product is a not ready-for-use machine in terms of the machine directive. It is intended exclusively for installation in a machine or in ventilation equipment and installations or for combina- tion with other components to form a machinery or installation.
  • Page 5: Improper Use

    Overhead load warning! Indicates possible hazards due to overhead loads. Failure to observe the warnings may result in death, injury and/or damage to property. Important instructions follow! Instructions for safe, optimum use of the product. www.ruck.eu...
  • Page 6: Adhere To The Following Instructions

    After cleaning, make sure that the product is working correctly again. 2.5.6. During maintenance and repair If operated correctly, ruck products only require a minimum amount of maintenance. Please • follow all of the instructions given in section 10 in this respect.
  • Page 7: Safety Labels On The Product

    Do not use aggressive or Read the operating manual before easily flammable products for cleaning (impellers/ commissioning the product. housing). → Only use mild soapsuds. The impeller should be clea- ned with a cloth or brush. Bypass www.ruck.eu...
  • Page 8: Delivery Contents

    Deutsch Delivery contents Included in delivery depending on model type: • 1 x SLIGHTLINE air extraction unit with diagonal fan • 1 x EC fan • 4 x Brackets • 1 x Installation and operating manual Product and Performance description The SLIGHTLINE compact supply air unit is a complete, ready-to-use supply air unit.
  • Page 9: Transport And Storage

    2/3 the unit‘s maximum pressure so that an adequate air output can still be achieved. This will prevent malfunction. Pressure losses in the duct system are adversely affected by: the length of the duct system, small duct cross-section, elbows, additional filters, valves, etc. www.ruck.eu...
  • Page 10: Permitted Installation Positions

    Deutsch Install insulated against structure-borne sound! Fig. 5: Unit suspension 6.1. Permitted installation positions The unit is solely for ceiling mounting in a horizontal installation position. The warranty applies only to units which has been mounted workmanlike as depicted in the „permis- sible mounting position“.
  • Page 11: Electrical Connection

    The unit may only be operated with the correct overcurrent protection. • This must be established by a qualified electrician. • The recommended protection is shown in the enclosed wiring diagram. • Pre-fuse 10 A up to max. voltage of 240 V. www.ruck.eu...
  • Page 12: Commissioning

    Deutsch Commissioning • Electricity warning (hazardous voltage) Failure to observe the hazard may result in death, injury or damage to property. » → Before performing any work on conductive parts, always disconnect all of the unit from the electricity supply with all poles and make sure that it cannot be switched back on again. •...
  • Page 13: Maintenance And Repair

    Servicing, troubleshooting and cleaning may only be performed by specialised personnel in accordance with this installation and operating manual and the regulations in force. If operated correctly, ruck products only require a small amount of maintenance. The following work should be performed at regular intervals, in accordance with health and safety regulations: •...
  • Page 14: Dismantling And Disposal

    If you have not been able to remove the fault, please contact the manufacturer. The contact address can be found at www.ruck.eu or on the back cover of this assembly and operating manual. 13.1. Possible operating faults Further faults may occur before and during operation of the unit.
  • Page 15: Technical Data

    WA 2 Fan stage stepless (0 - 10V) stepless (0 - 10V) stepless (0 - 10V) stepless (0 - 10V) 130303 136709 136705 136705 Wiring diagram No. Fig. 7: Dimensions of the supply air unit 15. Wiring diagrams www.ruck.eu...
  • Page 16 This document, as well as the data, specifica- tions and other information set forth in it, are the exclusive property of ruck Ventilatoren GmbH. It may not be reproduced or given to third par- ties without its consent.