Specifications; Wiring Diagram - Desa Air Conditioner Owner's Manual

Propane construction forced air heater variable 30-55,000, 50-85,000 and 75-125,000 btu/hr
Table of Contents

Advertisement

All Models
• Propane/LP Gas
• Gas Supply Pressure to Regulator -
Max - Bottle Pressure, Min - 5 psig (34.5 kPa)
• Gas Supply Pressure Regulator Out -
28" WC (6.97 kPa)
• Electrical Input - 115V, 60 Hz, 1Ø, 3a
• Direct Spark Ignition
• Primary Flame Control -
Thermocouple operated gas valve
• Minimum Ambient Temp. Rating -
0° F (-17.8° C)
• Heated Air Output - 350 CFM (9.91 m
CONNECTION DIAGRAM/
DIAGRAMA DE CONEXIONES/
DIAGRAMME DE CONNEXION
Thermocouple/Termopar
Orange/
Orange/
Naranja
Naranja
Relay/Relé/Relais
Black/Negro/Noir
White/Blanco/
Blanc
Green/Verde/Vert
Line Cord/
Cable de línea/
Cordon électrique
10
SPECIFICATIONS
/min)
3

WIRING DIAGRAM

Motor/
Moteur
Ignitor/
Encendedor/
Allumeur
L1
L2
Red* or Yellow*/
Rojo* o Amarillo*/
Rouge* ou jaune*
Red* or Yellow*/
Rojo* o Amarillo*/
Rouge* ou jaune*
• If any original wiring as supplied with the heater must be replaced, it must be replaced with
type AWG 105° C wire or its equivalent except as indicated (*Type SF2-200. **SGI-250° C)
• Si es necesario reemplazar algún cable suministrado originalmente con el calentador, éste se debe reemplazar con
cable tipo AWG 105° C o su equivalente, excepto cuando se indica lo contrario (*Tipo SF2-200. **SGI-250° C)
* Si le câblage fourni avec l'appareil de chauffage doit être remplacé, faites-le avec du câble de type AWG 105° C
ou son équivalent, sauf indication contraire (*Type SF2-200. **SGI-250 °C)
www.desatech.com
55,000 Btu/Hr Models
• 30-55,000 Btu/Hr (8.8 - 16.1 kW)
• Fuel Consumption
1.4 - 2.6 pounds/hr (0.70 - 1.28 kg/hr)
• Fuel Orifice Port No. - 18
• Fuel Orifice Port Size - 0.0196" (0.50 mm)
• Average Air Temp. Rise - 200° F (111° C)
85,000 Btu/Hr Models
• 50-85,000 Btu/Hr (14.6 - 25.0 kW)
• Fuel Consumption
2.3 - 3.9 pounds/hr (1.04 - 1.77 kg/hr)
• Fuel Orifice Port No. - 18
• Fuel Orifice Port Size - 0.024" (0.60 mm)
• Average Air Temp. Rise - 200° F (111° C)
125,000 Btu/Hr Models
• 75-125,000 Btu/Hr (21.9 - 36.6 kW)
• Fuel Consumption
3.5 - 5.8 pounds/hr (1.59 - 2.63 kg/hr)
• Fuel Orifice Port No. - 18
• Fuel Orifice Port Size - 0.030" (0.75 mm)
• Average Air Temp. Rise - 400° F (232° C)
Spark Plug/
Bujía/Bougie
Black** or
Orange**/
Negro** o
Naranja**/
Noir** ou
orange**
Green/Verde/Vert
115V
High-Limit
60HZ
Switch/
Interruptor de
límite alto/
Commutateur de
limite supérieure
SCHEMATIC DIAGRAM/
DIAGRAMA ESQUEMÁTICO/
DIAGRAMME DE CIRCUIT
Black/Negro/Noir
Spark Plug/
Bujía/Bougie
Motor/
Moteur
L1
Relay/
L2
Relé/
Ignitor/
Relais
Encendedor/
Allumeur
White/Blanco/Blanc
High Limit
Switch/
Interruptor de
límite alto/
Interrupteur de
limite supérieure
Gas
Valve
Válvula de gas/
Robinet de gaz
113893-01B

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents