Introduction to AMS 700 Penile Prosthesis
Overview of AMS 700 Penile Prosthesis
Provides an overview of the AMS 700 Penile Prosthesis product line and its components.
Device Description and Configurations
Penile Prosthesis Components
Details the cylinders, pump, and reservoir components of the AMS 700.
AMS 700 CX and LGX Configurations
Outlines the configurations for AMS 700 CX and LGX MS Pump prostheses.
AMS 700 CXR Configuration
Describes the specific design and configurations of the AMS 700 CXR prosthesis.
Device Sterilization and Storage Guidelines
Sterilization and Tools
Covers component sterilization, handling cautions, and available surgical tools.
Storage Guidelines
Provides recommendations for proper storage of AMS 700 components.
Operating Room Instructions and Preparation
Preoperative Setup and Equipment
Lists required instruments and sterile supplies for the procedure.
Equipment Preparation
Details unpacking the accessory kit and preparing hemostats for surgery.
Surgical Procedures for AMS 700 Penile Prosthesis
Patient Preparation and Surgical Approach
Prepares the patient and outlines infrapubic and penoscrotal surgical approaches.
Incision and Dissection Techniques
Details making incisions and dissecting tissues for prosthesis implantation.
Cylinder Sizing and Preparation
Covers dilation, measurement, and selection of appropriate cylinder sizes.
Component Preparation Steps
Instructions for unpacking, preparing, and filling all prosthesis components.
Component Implantation Procedures
Guides for inserting cylinders, implanting the reservoir, and implanting the pump.
Device Testing and Connection
Procedures for initial and surrogate testing, and connecting all components.
Tubing Connection Methods
Explains methods for connecting prosthesis tubing using specific connectors.
Final Device Testing and Closure
Final inflate/deflate test, closure of incision, and post-procedure dressing.
Postoperative Procedures and Patient Care
Immediate Postoperative Care
Immediate care instructions after surgery, including drain placement and penis support.
Post-Discharge Patient Guidance
Guidance for patients after hospital discharge, including pump positioning and cycling.
Long-Term Function Evaluation
Recommendations for follow-up evaluations and monitoring of the implanted device.
Combining Components of Different AMS 700 Models
AMS 700 Component Combinations
Information on combining different AMS 700 components for specific patient needs.
Troubleshooting AMS 700 Penile Prosthesis
Cylinder Issues and Solutions
Solutions for common problems with prosthesis cylinders like sizing or inflation.
Reservoir Issues and Solutions
Troubleshooting for reservoir problems such as filling difficulties or punctures.
Pump Issues and Solutions
Solutions for pump-related problems like dimpled bulbs or inflation/deflation failures.
AMS 700 Product Line Matrix
AMS 700 MS Pump Product Line Overview
A matrix detailing reservoir recommendations and configuration options for AMS 700 models.
Appendix: Technical Information
InhibiZone Antibiotic Surface Treatment
Explains the AMS InhibiZone antibiotic surface treatment and its benefits.
Parylene Coating on Cylinders
Describes the Parylene coating applied to the cylinders for wear reduction.
Brief Summary and Safety Information
Summarizes device indications, contraindications, and potential adverse events.