DIAGNOSTICS
DIAGNOSTICS
DIAGNOSTICS
DIAGNOSTICS
DIAGNOSTICS
The following is an example of how an alarm is displayed on the 2nd line of the CRT when an
alarm occurs. The 1st group of asterisk on the left display the alarm number and axis code. This
axis code indicates which axis the alarm is being generated by if any. To the right of the alarm
number and axis code, the alarm level is displayed followed by a message. Then to the far right
is the alarm code. This code is in a hexadecimal format and sometimes needs to be converted to
a binary format to decipher the source of the problem. Look up the alarm in the "Alarm & Error
List" manual for an explanation of the alarm.
MDI OPERATION
****-** ALARM-*
XA
ZA
XB
ZB
ACTUAL
DATA
POSIT
INPUT
F1
F2
Alarm Message
20.0378
45.0496
25.0267
40.0845
Part
BLOCK
DATA
Program
F3
F4
Okuma America Corporation
N
Alarm Code
SEARCH
F6
F5
6-20
0
CHECK
EXTEND
DATA
F7
F8
Rev. 8-21-01