Battery system monitor, Models TM-2030-RV and TM-2030-A
IMPORTANT: The wiring installation for this meter, especially the shunt installation
must be performed by someone knowledgeable in proper wiring, electrical practices,
and safety. If you do not have this knowledge please have someone install it who does,
or at least get some competent help to supervise the installation.
To install:
1. Please read or scan two pages of introductory information in section A.
2. Consult drawings Figure 1 and 2 (pages 7-8).
3. Follow step by step installation instructions in section B.
4. Program the two most important parameters into meter (section C1).
A. Before installing the TriMetric meter:
B. How to Install Meter and Shunt:
C1. How to determine program item P3: "battery system capacity"
C2. How to program your meter for the 100A/100mV shunt.
C3. Optional: Now or later you may wish to program P4, P5, P6
Warranty and customer service
Limited warranty
The TriMetric TM-2030 is warranted for three years against any manufacturing defect. Any meter not meeting the
specification or rated performance shall be replaced or repaired, at Bogart Engineering's discretion, provided it has not
been subjected to abuse or misapplication. For warranty service, please email bogart@bogartengineering.com. A return
merchandise authorization is required for all merchandise to be returned to Bogart Engineering.
How to obtain customer service
Please review our support page before attempting to contact us. Our distributors are able to answer simple
questions
about
bogart@bogartengineering and someone will assist you.
TriMetric
Technical Manual
INSTALLATION Page 1-7
USER GUIDE Page 8-23
Bogart
Engineering
BOGART ENGINEERING
www.bogartengineering.com
TM-2030
revised June 2017
products.
For
technical
1
support,
send
an
email
to

Advertisement

loading
Need help?

Need help?

Do you have a question about the TM-2030-A and is the answer not in the manual?

Questions and answers

Summarization of Contents

Before Installing the TriMetric Meter
Reviewing Installation Prerequisites
Text guiding user on initial steps before installation begins.
How to Install Meter and Shunt
Determine Battery System Capacity (P3)
Explains how to find and set the battery system capacity parameter (P3).
Program Meter for 100A/100mV Shunt
Guides programming the meter for specific shunt types for accurate readings.
Optional Programming (P4, P5, P6)
Details optional programming parameters for advanced features and reminders.
Warranty and Customer Service
Limited Warranty Details
Outlines the terms and duration of the product's limited warranty.
Obtaining Customer Service
Provides instructions on how to contact support for assistance and inquiries.
How to Install Meter and Shunt
Installation Preliminary Steps
Covers essential safety and preparation before meter and shunt installation.
Required Tools and Materials
Lists necessary tools, cables, and components for the installation process.
Eight Steps for Shunt and Meter Installation
Provides a step-by-step guide for physically installing the shunt and meter.
Basic Instructions for Operating Level L1
Details on Less Used Display Items
Explains five less commonly used display features for user information.
Battery Reminders Explained
Describes the optional battery reminder feature for maintenance and charging.
User Levels L2, L3, L4 Applicability
Identifies which users might benefit from advanced operating levels.
Technical Reference Section
TM-2030 Specifications
Provides detailed technical specifications for the TriMetric TM-2030 monitor.
Battery % Full Calculation Method
Explains the internal logic and parameters used for calculating battery percentage full.