  • Page 1: Operating Instructions

    Operating Instructions Hidrion Mod. H50, H100 and H200 Warning: Read these instructions before using appliance (1641 of ISO 7000).
  • Page 2 Since the beginning of its distribution in 1997, more than 5,000 systems have been installed. By installing HIDRION in your swimming pool, you are keeping maintenance to a minimum, and you can enjoy pure, crystal clear water, virtually free from hazardous chemical products which can cause allergies and skin irritations.
  • Page 3: Table Of Contents

    6.1 – Water conductivity……………………………………..…………………….……………….22 6.2 – Cleaning electrodes..….……………………………….…………………………………… 23 6.3 – Replacing electrodes ……….…………………………………….………………………….23 PRODUCED BY HIDROSWIM – HIDRION ÁGUA Rua Martins Barata nº 5E 1400 - 247 Lisboa TEL. +351 213 039020 / FAX +351 213 039022 (V20122924) WWW.HIDRION.EU...
  • Page 4: Declaration Of Conformity

    Devices : Hidrion Models : H50 : H100 : H200 Lisbon, 24 September 2012. PRODUCED BY HIDROSWIM – HIDRION ÁGUA Rua Martins Barata nº 5E 1400 - 247 Lisboa TEL. +351 213 039020 / FAX +351 213 039022 (V20122924) WWW.HIDRION.EU...
  • Page 5: Safety Information

    For detailed information about recycling this product, please contact your local council, or the retailer the product was bought. PRODUCED BY HIDROSWIM – HIDRION ÁGUA Rua Martins Barata nº 5E 1400 - 247 Lisboa TEL. +351 213 039020 / FAX +351 213 039022 (V20122924)
  • Page 6: Assembly Instructions

    1 – ASSEMBLY INSTRUCTIONS 1.1 – HIDRION ELECTRICAL SWITCHBOARD Screw the fixing brackets to the upper part of the HIDRION electrical switchboard using the screws supplied and the pre-existing holes in the box. Attach the HIDRION electrical switchboard to the wall, next to the pump electrical switchboard, in a dry, easily-accessible place, preferably at eye level.
  • Page 7: Hidrion Ioniser

    Bypass assembly. The HIDRION ioniser can be attached to PVC piping of ø 63mm (H100 and H200 models) or ø 50mm (H50 model). If necessary, a 63-50 mm reducing bush can be glued to the ioniser input and output.
  • Page 8: How It Works

    NB: The ioniser unit is made of PVC, therefore a suitable glue for this type of material should be used. For H50 and H100 models, the ioniser power source max. 24 V / 0.6 A) comes from the DC output (output for electrodes in the lower right-hand corner) of the electrical switchboard and is connected to the ioniser source by terminals.
  • Page 9 In order to control the operation of HIDRION, and for practical reasons, we decided to control the amount of copper in the water, so that the metal ion (Cu ++) concentration is kept between 0.3 and 0.5 mg/l (1 mg/l = 1 ppm – parts per million).
  • Page 10: Start-Up Phase

    3 –START-UP PHASE During the start-up phase, there are no copper ions in the water, so HIDRION should be run to introduce the first copper ions into the water automatically, regulated by the ionisation system. The table below shows the running times needed for HIDRION to...
  • Page 11: Water Chemistry - Parameters To Control

    Important Note: To keep the swimming pool water in its best conditions and ensure optimum running of the HIDRION system, water pH should be kept between 7.0 and 7.4 (see Chapter 4.3.1 – page 15). As soon as the water copper concentration reaches 0.3 – 0.5 mg/l, the maintenance routine begins (see Chapter 5 - page 19).
  • Page 12 The use of HIDRION itself does not affect the pH of your pool water, but controlling it is crucial to maintaining water quality. What is the effect of low pH? Irritation of the skin and mucus membranes (e.g. eyes, nose and ears).
  • Page 13: Alkalinity

    If the product does not have any specific instructions, you may follow this procedure: PRODUCED BY HIDROSWIM – HIDRION ÁGUA Rua Martins Barata nº 5E 1400 - 247 Lisboa TEL. +351 213 039020 / FAX +351 213 039022 (V20122924) WWW.HIDRION.EU...
  • Page 14: Copper

    Keep your total water alkalinity between 80 and 120 ppm. 4.3 – COPPER Copper is the main element to control in order to check that HIDRION is working properly (copper ion concentration). PRODUCED BY HIDROSWIM – HIDRION ÁGUA Rua Martins Barata nº...
  • Page 15: Copper And Ph

    Keep free copper at 0.3 – 0.5 ppm and pH at 7.0 – 7.4. free Cu 4.3.2 – Copper testing kit A copper testing kit is supplied with your HIDRION system, so you can measure the concentration of free copper in the water. PRODUCED BY HIDROSWIM – HIDRION ÁGUA Rua Martins Barata nº...
  • Page 16 (by regulating the dial – potentiometer – on the HIDRION switchboard). PRODUCED BY HIDROSWIM – HIDRION ÁGUA Rua Martins Barata nº 5E 1400 - 247 Lisboa TEL. +351 213 039020 / FAX +351 213 039022 (V20122924) WWW.HIDRION.EU...
  • Page 17: Chlorine

    0.3 and 0.5 mg/l. 4.4 - CHLORINE As we have already mentioned, HIDRION will drastically reduce the usual consumption of chlorine (by around 90-95%). The amount of chlorine used is minimal and it is less than the amount of chlorine found in drinking water.
  • Page 18: Cyanuric Acid

    At the end of the start-up phase, the pool water copper content should be between 0.3 and 0.5 ppm. The HIDRION control panel shows either a graph or table which allows the user to estimate ioniser current intensity for the H50 model, H100 model or to H200 model, depending on the swimming pool volume and pump routine.
  • Page 19 HIDRION switchboard regulation according to the pool volume and to the number of the pump functioning hours Daily swimming pool pump functioning hours Optimal H50 and H100 ioniser current intensity. HIDRION switchboard regulation according to the pool volume and to the number of the pump...
  • Page 20 0.5ppm). Once this value is stabilised and is within the defined limits, the copper test needs to be carried out only once a week (using the testing kit supplied with HIDRION – see Chapter 4.3.2, page 16). When the pool reaches the maintenance routine stage with HIDRION, as described...
  • Page 21 On-off switch (should Current intensity be in position “I” to regulation start running with Potentiometer pump) HIDRION switchboard, H50 and H100 models. Light indicating the need to check/replace the electrodes Lights indicating the current intensity level (1 to 10) Polarity...
  • Page 22: Useful Tips

    This means the water used to refill the pool has only small amounts of minerals. HIDRION needs a certain amount of minerals to provide the current intensity necessary for ionisation to occur. Adding some salt to the water (begin by adding 1kg of...
  • Page 23: Cleaning Electrodes

    Wait and until you see that the electrodes lose the white coating and become cleaner. Put the electrode kit back into the HIDRION jar and close it with the PVC lid. You should then be able to regulate copper production on the HIDRION switchboard (when turning the potentiometer, the lights come on).
  • Page 24 (visible external damage). This Guarantee covers the "Hidrion" system only, excluding any other goods, equipment or parts involved in the pool system in which "Hidrion" is used. It does not include replacement electrodes, regardless of their use when the malfunction takes place.

Table of Contents