M5300-PM BACK PANEL FEATURES
2. Outlet Bank 5
1. 15A Main Circuit
Two switched, high-current outlets controlled by
Breaker:
the front panel Power Button or the DC Trigger in-
Automatically opens
put. Bank 5 has a 5 second turn on delay and turns
when the current load
off immediately upon shutdown. The High Current
is greater than 15
outlets provide power from a low impedance noise
Amps. Push to reset.
filtration circuit that does not limit the current to
your equipment. Its output is noise-isolated from all
other outlet banks.
7. Ground Lug:
6. Main Power Cord 10ft.
Must be plugged into a
Provides a common
grounding point for
properly wired & grounded
equipment with separate
3-wire outlet
.
ground leads.
M5300-PM SPECIFICATIONS
General________________________________________________________________
Dimensions .....................................17 in. W x 12.75 in. D x 3.5 in H, (4.1 in. Including feet)
Weight ..........................................................................................................................14 lbs.
AC Power_______________________________________________________________
Line Voltage ........................................................................................................120V, 60Hz
Voltage Regulation.............................................................................................................No
Total Current Capacity .....................................................................................15 A (1800 W)
Voltage Protection Rating (UL1449 3rd Edition, 3,000A).............................................. 500V
Protection Modes ............................................................................................L-N, L-G, N-G
Initial Clamping Level ....................................................................... 200V Peak, 141V RMS
Energy Dissipation ..............................................................................................2350 Joules
Peak Impulse Current ...................................................................................... 75,000 Amps
Catastrophic Surge Circuit ...............................................................................................Yes
Thermal Fusing ................................................................................................................Yes
Auto-resetting Over-voltage shutoff ..........................................................142 VAC ± 8 VAC
Auto-resetting Under-voltage shutoff ..........................................................86 VAC ± 6 VAC
EMI/RFI Noise Filtration___________________________________________________
Bank 1 ............................................................................... Up to -86 db (100 KHz – 2 MHz)
Bank 2 ............................................................................... Up to -91 db (100 KHz – 2 MHz)
Bank 3 ............................................................................... Up to -81 db (100 KHz – 2 MHz)
Bank 4 ............................................................................. Up to -100 db (100 KHz – 2 MHz)
Bank 5, High Current Outlets ............................................ Up to -81 db (100 KHz – 2 MHz)
DC Trigger Input__________________________________________________________
Jacks....................................................................................... 3.5mm (1/8") mono mini-plug
Voltage and Polarity........................................................................ 3 - 24V DC, bidirectional
Current Requirement.................................................................. 4.6 mA @3V, 58 mA @24V
DC Trigger Output________________________________________________________
Pass through........................................................................................................... no delay
Positive = Tip, Negative = Ring
UPC'S, QUANTITIES, WEIGHTS & MEASUREMENTS FOR ORDERING & SHIPPING
MODEL M5300-PM
Dimensions
Weight
17" x 12.75" x 3.5"
14 lbs
4.1" H with feet
3. Outlet Banks 3 and 4
Each bank features two switched outlets with linear
filtration technology (LiFT) controlled by the front
panel Power Button or the DC Trigger input. Banks
3 & 4 will turn on immediately and turn off after a
10 second delay. LiFT EMI/RFI noise filtration is
provided by a two-stage balanced Pi filter which
also provides noise isolation from all other outlet
banks.
8. Bank 1 & 2 Indicator
9. Voltage Sense Trigger
Light
Output
Normally ON, is lit when
3.5mm (1/8") Mini-Plug jack.
there is power present
Connecting a trigger wire to
on the Bank 1 and 2
the Voltage Sense Output jack
receptacles.
will allow the input signal to
pass through the M5300-PM to
control the startup/shutdown of
an additional device.
Dimensions
23.25" x 19" x 9.25"
1690 Corporate Circle, Petaluma, CA. 94954 • 800-472-5555 • 707-283-5900 • Fax 707-283-5901 • www.panamax.com
© 2009 Panamax, Inc. Panamax, MAX, and the Panamax logo are registered US trademarks of Panamax
10. Voltage Sense Trigger
Input
3.5mm (1/8") mono mini-plug.
Connect to a remote trigger
device that uses a DC output
to trigger a startup/shutdown
sequence.
LAN Protection__________________________________________________________
Clamping Level...................................................................................................... 60V ± 5V
Compatibility........................................................................................................... 10/100bT
Connectors.................................................................................................................. RJ-45
Wires Protected:....................................................................................................... 8-Wires
USB Circuit_____________________________________________________________
Jacks......................................................................................................................... USB-A
Power Delivery......................................................................................... 500 mA @ 5 VDC
Telco Protection__________________________________________________________
Fuseless/Auto-resetting..................................................................................................Yes
Clamping Level.............................................................................................................260V
Capacitance....................................................................................................30pf (approx.)
Suppression Modes..........................................................................Metallic & Longitudinal
Wires Protected.......................................................................................2-Wire, Pins 4 & 5
Connectors..................................................................................................................RJ-11
Universal Coax Protection________________________________________________
HD 1080 i/p Ready..........................................................................................................Yes
Shielded..........................................................................................................................Yes
Clamping Level...............................................................................................................75V
Frequency Range...................................................................................... 0 MHz - 2.2 GHz
Insertion Loss......................................................................................................... < 0.5 dB
Connectors.....................................................................................Female "F", Gold Plated
Bidirectional....................................................................................................................Yes
Design and specifications subject to change without notice due to product improvement.
UNIT CARTON
Weight
UPC
18 Lbs
0 50616 00816 7
4. Outlet Banks 1 and 2
Each bank features two always-on outlets with
linear filtration technology (LiFT). Power will
only be turned off under a fault condition. (See
specifications for over-voltage and under-voltage
thresholds). LiFT EMI/RFI noise filtration is
provided by a two-stage balanced Pi filter which
also provides noise isolation from all other
outlet banks.
11. LAN Jacks
Protection circuits for 10/100 baseT Ethernet
lines. For the LAN 2 protected jacks, the
incoming LAN line MUST be plugged into the
LINE jack and the patch cord to the equipment
MUST be plugged into the EQUIP jack. For the
LAN 1 protected jacks the incoming LAN line
must be plugged into the LINE jack and the
equipment must be plugged into the gaming
jack on the front panel. 8 wire protection, 60V ±
5V clamping.
MASTER CARTON
Qty
Dimensions
Weight
1
23.75" x 19.75" x 10"
20 Lbs
5. Universal Coaxial
Connectors
3 pairs of bidirectional
protection circuits optimized for
satellite, cable, and antenna
TV signal lines.
12. Phone Jacks
Protection circuits for standard
telephone or pay-per-view lines.
Phone circuit is autoresetting.
Incoming phone cord MUST be
plugged into the LINE jack. Patch
cords to the equipment (satellite
receiver, digital video recorder,
telephone, etc.) MUST be plugged
into the EQUIP jacks.
UPC
5 00 50616 00816 2