MAX
5300-EX REAR PANEL FEATURES
®
Circuit Breaker
Outlet Bank 3
Automatically opens
Two switched, high current outlets controlled by the front
when the current load
panel Power Button or the DC Trigger input. Bank 3 has a 5
is greater than 15
second turn on delay and turns off immediately. The High
Amps.
Current outlets provide power from a low impedance noise fil-
tration circuit that does not limit the current to your equip-
ment. Its output is noise isolated from all other outlet banks.
Main Power
Ground Lug
Must be plugged
Provides a common
into
a
properly
grounding point for
wired & grounded
equipment with sep-
3-wire outlet
arate ground leads.
MAX
5300-EX SPECIFICATIONS
®
AC Power
Line Voltage:____________________________________________________120V, 60Hz
Total Current Capacity:__________________________________________________15 A
UL1449 Suppression Rating:____________________________________________330V
Protection Modes:______________________________________________L-N, L-G, N-G
Initial Clamping Level:_________________________________________________200V
Energy Dissipation:______________________________________________1815 Joules
Peak Impulse Current:___________________________________________73,000 Amps
Catastrophic Surge Circuit:_______________________________________________Yes
Thermal Fusing:_______________________________________________________Yes
Over-voltage shutoff:__________________________________________142 VAC ±5 VAC
Under-voltage shutoff:_________________________________________90 VAC ± 2 VAC
EMI/RFI Noise Filtration
Banks 1 - 4:_________________________________________ 90 db, 100 KHz – 2 MHz
Bank 3, High Current Outlets:____________________________60 db, 100 KHz – 2 MHz
Common Mode (all banks)____________________________ 60 db, 100 KHz - 2 MHz
DC Trigger Input
Jacks:_______________________________________________3.5mm (1/8") mini-plug
Voltage and Polarity:___________________________________3 - 24V DC, bidirectional
Current Requirement:_________________________________4.6 mA @3V, 58 mA @24V
LAN Circuit
Clamping Level:____________________________________________________8V ± 2V
Jacks:_____________________________________________________________RJ-45
Wires Protected:_______________________________________4-Wires, Pins 1, 2, 3 & 6
UPC's, QUANTITIES, WEIGHTS & MEASUREMENTS FOR ORDERING & SHIPPING
MODEL M5300-EX
Dimensions
Weight
17" x 12.75" x 3.5"
17 lbs
4.1" H with feet
OPTIONAL SILVER BEZEL
SILVER BEZEL
PRODUCT
Model #
Dimensions
BEZ5300-EXS
17" W x 0.625" D x 3.5" H
The Power Specialists Since 1975
1690 Corporate Circle, Petaluma, CA 94954
®
© 2005 Panamax. Panamax, MAX and the Panamax logo are registered US trademarks of Panamax. Protect or Disconnect and AVM are trademarks of Panamax. SIDACtor is a registered US trademark of Teccor Electronics, Inc.
Outlet Bank 2
Four switched outlets controlled by the front panel
Power Button or the DC Trigger input. Bank 2 will
turn on immediately and turn off after 10 seconds.
EMI/RFI noise filtration is provided by a three-stage
balanced Pi filter which also provides noise isolation
from Outlet Banks 1 and 3.
Specifications subject to change due to product upgrades and improvements.
UNIT CARTON
Dimensions
Weight
23.75" x 19.25" x 9.5"
20.5 Lbs
Weight
Dimensions
14.5 Oz
18" x 4" x 1"
Outlet Bank 1
Four always on outlets. Power will only be turned
off under a fault condition. (See specifications for
over-voltage and under-voltage thresholds) Power
is cleaned by a three-stage balanced Pi filter which
also provides noise isolation from Outlet Banks 2
and 3.
Telephone Circuit (pay-per-view)
Fuseless/Auto-resetting:_________________________________________________Yes
Clamping Level:______________________________________________________260V
Capacitance:__________________________________________________30pf (approx.)
Suppression Modes:____________________________________Metallic & Longitudinal
Jacks:_____________________________________________________________RJ-11
Wires Protected:___________________________________________2-Wire, Pins 4 & 5
DSL Compatible_______________________________________________________Yes
HD Satellite TV Circuit
Bidirectional:__________________________________________________________Yes
Shielded:_____________________________________________________________Yes
Clamping Level:_______________________________________________________27V
Attenuation:______________________________________< 1db from 950MHz-2.05GHz
Connections:__________________________________________Female "F", Gold Plated
HD Cable TV Circuit
Bidirectional:__________________________________________________________Yes
Shielded:_____________________________________________________________Yes
Clamping Level:_______________________________________________________1.4V
Attenuation:________________________________________< 1db from 5MHz- 950MHz
Connections:__________________________________________Female "F", Gold Plated
Pay-Per-View Compatible________________________________________________Yes
UPC
Qty
0 50616 00786 3
1
UNIT CARTON
Weight
UPC
18.5 Oz
0 50616 00792 4
800-472-5555 or 707-283-5900
Satellite TV Coax Jacks
Bidirectional protection circuit optimized
for satellite TV signal lines.
Voltage Sense
LAN Jacks
Trigger Input
Protection circuits
for 10/100 baseT
3.5mm (1/8") Mini-Plug
Ethernet lines.
jack. Connect to a remote
trigger device that uses a
DC output to trigger a start-
up/shutdown
sequence.
This bypasses the front
panel power switch.
MASTER CARTON
Dimensions
Weight
Same as
20.5 Lbs
Unit Carton
MASTER CARTON
Qty
Dimensions
Weight
N/A
N/A
Fax - 707-283-5901
Cable TV Coax Jacks
Bidirectional protection circuit opti-
mized for cable TV, off-air antennas
and cable modem signal lines.
Phone Jacks
Protection circuits for standard
telephone or pay-per-view lines.
Phone circuit is auto-resetting.
< 2.4db @ 2.2GHz
UPC
5 00 50616 00786 8
UPC
N/A