Download Print this page

Qlightec S125R User Manual

Bulb revolving warning light

Advertisement

Quick Links

Bulb Revolving Warning Light
S125R/ S125U
90dB
20
50
44
Thank you for purchasing Qlight's products. Please read this user manual carefully
prior to installation and operation to ensure safe and correct use.
Precautions for Safety
Failure to follow the instructions below may cause a loss of life or serious physical injury.
1. During wiring or maintenance, please completely turn off the power of the product. (Failure to follow this may lead to an electric shock.)
2. Do not install the product in locations that subjects it to excessive dust or water other than the conditions designated by the IP protection
ratings indicated for each product. (Failure to follow these instructions may cause a fire to the product, electric shock, physical injury,
malfunction or damage to the product.)
3. Do not alter or repair this product. If maintenance or repair service is required, please contact your local Qlight contact point. (Failure to
follow these instructions may lead to fire, electric shock, or product damage.)
4. Please apply the correct voltage to the product. (Failure to follow these instructions may lead to fire, electric shock, or product damage.)
5. When the product is applied to a condition that may impact lives or property, please make sure to have a double safety device. (Failure to
follow this may cause damage to property, fire, electric shock and loss of life.)
Precautions for Correct Use
Failure to follow the proper instructions may cause damage to property, the product, or malfunction of the product
that would void the warranty.
1. Please remove any objects that can interrupt ventilation around the product.
2. Please turn off the power of the product immediately if it fails to operate properly.
3. Carefully wire the product according to each product's specification.
4. Please be careful in preventing chemicals such as thinner, benzene, etc. in contact with the surface of the product.
5. Do not apply excessive force/impact to the product.
6. Failure to follow any of the instructions above may cause malfunction or damage to the product, fire, and electric shock.
Ordering Specifications
S125R -
BZ
-
[Model
[Buzzer]
number]
|
|
• S125R
• None
• 12 - DC12V
• S125U
- No buzzer type
• 24 - DC24V
• 110 - AC110V
• BZ
• 220 - AC220V
- Built-in buzzer
type
Please scan the QR code for more
detailed product information.
www.qlight.com
Product Specifications
220
-
R
number
[Voltage]
[Color]
|
|
R-Red
S125R
A-Amber
G-Green
B-Blue
S125U
※ CE compliant : DC12V, 24V
• Protection rating : IP44
• Ambient operating temperature : -20°C to +50°C
Bulb specifications
Model
Voltage Current
Volts/
Watts
DC12V 965mA 12V10W
DC24V 565mA 24V10W
AC110V 130mA 12V10W
AC220V 65mA 12V10W
DC12V 965mA 12V10W
DC24V 565mA 24V10W
AC110V 130mA 12V10W
AC220V 65mA 12V10W
1
Certificate Weight
Configuration Part#
9
0.40kg
10
9
0.65kg
9
T16x35
15S
9
0.41kg
10
9
0.65kg
9
Color
R-Red
A-Amber
G-Green
B-Blue

Advertisement

loading
Need help?

Need help?

Do you have a question about the S125R and is the answer not in the manual?

Questions and answers

Summary of Contents for Qlightec S125R

  • Page 1 Bulb Revolving Warning Light S125R/ S125U 90dB Thank you for purchasing Qlight’s products. Please read this user manual carefully prior to installation and operation to ensure safe and correct use. Precautions for Safety Failure to follow the instructions below may cause a loss of life or serious physical injury.
  • Page 2 • Machine holes on the mounting surface referring to S125R S125U the diagram below. 3-Ø6 HOLES Lens(AS) Reflector PCD 85 (Heat resistant ABS) Light bulb S125R/ S125U ■ Bulb Replacement Instructions Housing (ABS) ① Disassemble Rubber spacer bulb ② Flatwasher Assemble...
  • Page 3 • Please refer to the dimensions below for installation of mounting brackets Dimensions Ø22 Ø22 PCD85 PCD85 PCD60~70 PCD60~70 PCD50 PCD50 360°/ 3- 360°/ 3- S125R Ø5.5 HOLES Ø5.5 HOLES S125U 6-Ø5.5 HOLES 6-Ø5.5 HOLES 4-Ø5.5 HOLES 4-Ø5.5 HOLES Ø10 CABLE ENTRY Ø10 CABLE ENTRY SWP125 SWM125 Installation Environment and Protection Rating •...
  • Page 4 RELIABILITY, FUNCTION OR DESIGN OR OTHERWISE. Head office : Suite #1510, STX-V Tower, 128 Gasan digital 1-ro, Geumcheon-gu, Seoul, Korea (Postal Code : 08507) Factory : 185-25, Mukbang-Ro, Sangdong-Myeon, Gimhae-Si, Gyeongsangnam-Do, Korea (Postal Code : 50805) www.qlight.com EN - S125R - 2405A...

This manual is also suitable for:

S125u