zeeltronic PCDI-10VT Programming Manual

Handheld, programmable cdi ignition and pv controller

Advertisement

Quick Links

www.zeeltronic.com
info@zeeltronic.com
updated 05.01.2014
firmware version: 20.130703
PROGRAMMING MANUAL FOR HANDHELD PROGRAMMER
PROGRAMMABLE CDI IGNITION AND PV CONTROLLER
TECHNICAL DATA
Limit values:
- minimum revs
- maximum revs
- minimum supply voltage
- maximum supply voltage
- max. supply voltage for 1 minute
- current draw
- maximum continuous current for shift light output
Circuit is protected against reverse supply voltage (wrong connection).
Features:
- CDI charged from hi voltage charging coils (generator)
- store and load function for 2 ignition maps
- one input for magnetic pickup
- external switch for changing ignition map while riding
- shift light output
- quick shift (shift kill)
- tachometer output
- advance/retard whole ignition curve
- three stage rev limit (retard timing, reduced spark, spark off)
- signal delay compensation
- timing calculation for every 1 RPM change (1000, 1002, .. , 9805, 9806, ...)
- programmable power valve actuation
- store and load function for 5 PV curves
- programmable PV deviation
- programmable max close and max open positions
- self PV test on power-up
- PV error detecting (position sensor failure, servo motor failure)
- easy and fast programming on the field, via hand held programmer
- programming while machine running - you can immediately see effects
- monitoring of rev's, ignition and PV angle, via LCD(hand held programmer)
- fast processing for high accuracy - delays from 1us
PCDI-10VT
- 1 -
200 RPM
20000 RPM
8 Volts
16 Volts
35 Volts
25 mAmp
1 Amp

Advertisement

loading
Need help?

Need help?

Do you have a question about the PCDI-10VT and is the answer not in the manual?

Questions and answers

Summary of Contents for zeeltronic PCDI-10VT

  • Page 1 05.01.2014 firmware version: 20.130703 PROGRAMMING MANUAL FOR HANDHELD PROGRAMMER PCDI-10VT PROGRAMMABLE CDI IGNITION AND PV CONTROLLER TECHNICAL DATA Limit values: - minimum revs 200 RPM - maximum revs 20000 RPM - minimum supply voltage 8 Volts - maximum supply voltage 16 Volts - max.
  • Page 2 HOW TO ENTER MENU PCDI must be connected to power supply. Connect programmer to PCDI and wait few seconds for activation of programmer and then press enter. With pressing + ,or - you can move through menu and select with pressing enter . Exit menu with selecting Exit.
  • Page 3 LOAD IGN. CURVE Enter menu and move to Load Ign. Curve with pressing + ,or - and then press enter . Select position number of previously saved ignition curve set, with pressing +, or - and then press enter . SAVE IGN.
  • Page 4 5.1. Change NUMBER OF IGNITION CURVE POINTS Move to Nr. of Points with pressing + , or - and then press enter . Select number of ignition points, with pressing + , or - and then press enter . 5.2. Change PARAMETERS OF IGNITION CURVE POINT Move to point you want to change, with pressing + , or - and then press enter .
  • Page 5 Set STATIC ANGLE Enter menu and move to Static Angle with pressing + , or - and then press enter . Now you can set static angle with pressing + , or - (in 0.1deg steps) and then press enter . More information's about static angle you can find in section 22.
  • Page 6 Set TRIGGER MODE Enter Set Ign. menu and move to Trigger Mode with pressing + , or - and then press enter. Change Trigger Mode with pressing + , or - and then press enter . Trigger signal from pickup consist of positive and negative pulse. Positive pulse must be first and is generated by leading edge of trigger bar...negative pulse must be second and is generated by trailing edge of trigger bar.
  • Page 7 LOAD PV CURVE Enter menu and move to Load PV Curve with pressing + , or - and then press enter . Select position number of previously saved ignition curve set, with pressing + , or - and then press enter . SAVE PV CURVE Enter menu and move to Save PV Curve with pressing + , or - and then press enter .
  • Page 8 Deviation Enter menu and move to Deviation with pressing + , or - and then press enter . Change deviation from 2% to 20% with pressing + , or - (in 1% steps) and then press enter . Deviation means how accurate valve is moved to calculated position. If deviation is too low then servo motor won't be stabile –...
  • Page 9 Example: Measured Static Angle = 39.2deg (this angle you must enter in PCDI) Calculating mm to deg or vice versa: MONITORING Connect programmer to PCDI and wait few seconds for activation of programmer. Fist information displayed on the programmer is software version. With programmer you can watch revs, calculated advance ignition angle and PV valve position.