TECHNICAL DATA
Limit values:
- minimum revs
- maximum revs
- minimum supply voltage
- maximum supply voltage
- max. supply voltage for 1 minute
- current draw
- maximum continuous current for shift light output
Circuit is protected against reverse supply voltage (wrong connection).
Features:
- CDI charged from hi voltage charging coils (generator)
- store and load function for 2 ignition maps
- one input for magnetic pickup
- external switch for changing ignition map while riding
- shift light output
- quick shift (shift kill)
- tachometer output
- advance/retard whole ignition curve
- three stage rev limit (retard timing, reduced spark, spark off)
- signal delay compensation
- timing calculation for every 1 RPM change (1000, 1002, .. , 9805, 9806, ...)
- easy and fast programming on the field, via hand held programmer
- programming while machine running - you can immediately see effects
- monitoring of rev's, ignition angle, via LCD(hand held programmer)
- fast processing for high accuracy - delays from 1us
Very important!
Resistor spark plugs must be used, because they produce less electromagnetic disturbances.
Very important!
PPV is protected against static discharge, but too high static charge can damage PPV.
Be careful when using programmer on the dyno, because static charge can build up on the bike and
static discharge can damage PPV unit, or programmer. Make ground connection between dyno and
bike frame to prevent static discharge.
PCDI-10T
PROGRAMMABLE CDI IGNITION
1
200 RPM
20000 RPM
8 Volts
16 Volts
35 Volts
25 mAmp
1 Amp

Advertisement

loading

Summary of Contents for zeeltronic PCDI-10T

  • Page 1 04.10.2016 firmware version: 20.130426 PROGRAMMING MANUAL FOR HANDHELD PROGRAMMER PCDI-10T PROGRAMMABLE CDI IGNITION TECHNICAL DATA Limit values: - minimum revs 200 RPM - maximum revs 20000 RPM - minimum supply voltage 8 Volts - maximum supply voltage 16 Volts - max.
  • Page 2 HOW TO ENTER MENU PCDI must be connected to power supply. Connect programmer to PCDI and wait few seconds for activation of programmer and then press enter. With pressing + ,or - you can move through menu and select with pressing enter . Exit menu with selecting Exit.
  • Page 3 Change IGNITION CURVE Enter menu and move to Ignition Curve with pressing + , or - and then press enter . Now you are in submenu for setting ignition curve. Submenu organisation: Nr. of Points - number of ignition curve points (from 4 to 10) - first ignition curve point - second ignition curve point Exit Curve...
  • Page 4 Set ADVANCE With this setting is possible to advance or retard whole ignition curve. When setting is positive then ignition curve is advanced and when setting is negative than ignition curve is retarded. With Advance 0.0deg, ignition curve is unchanged. Enter menu and move to Advance with pressing + , or - and then press enter .
  • Page 5 Change Compensation: Enter menu and move to Compensation with pressing + , or - and then press enter . Change compensation delay with pressing + , or - and then press enter . Set IGNITION MAP SW Enabling, or disabling ignition map switch for changing ignition curves while riding. Enter menu and move to Ign.
  • Page 6 When "only [+] signal" is checked, then only positive signal is detected and ignition timing is calculated with all revs as programmed with ignition map. When "[+] and [-] signal" is checked, then both signals are detected. Revs of first ignition point define switching point between, programmed ignition map and idle running timing position.
  • Page 7 MONITORING Connect programmer to PCDI and wait few seconds for activation of programmer. Fist information displayed on the programmer is software version. With programmer you can watch revs, calculated advance ignition angle and PV valve position. Information! You can connect or disconnect PCDI unit from programmer any time you want, without any harm.