Page 1
F-362/F-363/F-364/F-365 Beauty Instrument User Manual Welcome to use our products. Please read the user manual carefully before using the products. Our company reserves the right to improve design and modify the products without prior notice.
Page 2
Catalog About this manual Warning Product parameter and introduction of F-362 Product parameter and introduction of F-363 Product parameter and introduction of F-364 Product parameter and introduction of F-365 Hot and cold hammer introduction 10/11 Ultrasonic probe introduction 12/13 Skin Scrubber introduction...
This manual shall only be used for the reference of operation of this particular model. If the manual is used for other purposes, SILVERFOX will not undertake any according consequences and responsibility. All information of this manual shall be protected by copyright and shall not be copied and translated in any part of this specification without the written consent of our company SILVERFOX.
Components F-362 1. Diamond Dermabrasion 2. Radio Frequency 3. Ultrasonic 4. Scrubber 5. Hot and cold hammer Main Unit Dermabrasion Scrubber Dermabrasion Power socket suction adjuster Radio Frequency Rear Panel Hot and cold hammer Ultrasonic Front Panel 1. Hot and cold hammer 2.
Product Parameters Product model F-362 AC 100-240V,50/60Hz Rated voltage / Frequency Power 6.1kg Net weight 37×31.5×16.5cm Product size Package size 56.8×52.5×23.5cm Main Unit × 1 Accessories Shelf × 1 Hot and cold hammer × 1 Ultrasonic probe × 1 Scrubber × 1 Radio Frequency ×...
Page 6
Components F-363 1. Spray 2. Vacuum 3. Radio Frequency 4. Ultrasonic 5. Skin Scrubber 6.Hot and cold hammer Main Unit Spray Scrubber Spray /Vacuum Power socket adjuster RADIO SKIN SPRAY FREQUENCY SORUBBER Radio Frequency Rear Panel Hot and cold hammer COLD &...
Page 7
Product Parameters Product model F-363 AC 100-240V,50/60Hz Rated voltage / Frequency Power 6.2kg Net weight 37×31.5×16.5cm Product size Package size 56.8×52.5×23.5cm Main Unit × 1 Accessories Shelf × 1 Hot and cold hammer × 1 Ultrasonic probe × 1 Skin Scrubber × 1 Radio Frequency ×...
Page 8
Components F-364 1. Spray 2. Vacuum 3. Radio Frequency 4. Ultrasonic 5. High.frequency 6.Hot and cold hammer Main Unit Spray Galvanic Spray /Vacuum Power socket adjuster HIGH GALVANIC SPRAY FREQUENCY High Frequency Rear Panel Hot and cold hammer COLD & HOT ROTARY HAMMER BRUSH...
Page 9
Product Parameters Product model F-364 AC 100-120V,50/60Hz ; AC 220-240V,50/60Hz Rated voltage / Frequency Power 6.3kg Net weight 37×31.5×16.5cm Product size Package size 56.8×52.5×23.5cm Main Unit × 1 Accessories Shelf × 1 Hot and cold hammer × 1 High Frequency probe (including 4 kinds) × 1 Rotary brush (including 4 kinds) ×...
Page 10
Components F-365 1. Negative plate 2. Probe 3. CAP handle 4. RES handle Main Unit Power socket Rear Panel Negative plate Front Panel 1. RES 2. CAP Operation Method Operation procedure Click to choose the required function of main interface, and it will enter the interface of corresponding function.
Page 11
Product Parameters Product model F-365 AC 100-120V,50/60Hz ; AC 220-240V,50/60Hz Rated voltage / Frequency Power 400W 6.8kg Net weight 37×31.5×16.5cm Product size Package size 56.8×52.5×23.5cm Main Unit × 1 Accessories Shelf × 1 RES handle × 1 CAP handle × 1 Negative plate ×...
Function Introduction Hot and cold hammer Operation Cautions Warning This function is prohibited for the following people or parts : Patients with recurrent scar rash and allergic patients; Skin burns, scalds, sunburn, inflammation or other wounds; People suffering from immunosuppressive diseases resulting in low immunity, or are using immunosuppressive drugs;...
Page 13
Hot and cold hammer 1. Return to main interface 2. Temperature Decreasing Button Cooling temperature range: 5 ~25 Heating temperature range: 25 ~45 3. Temperature Display When you select the cooling mode, the displayed temperature is the cooling temperature When the heating mode is selected, the displayed temperature is the set heating temperature 4.
Page 14
Function Introduction Ultrasonic probe (Cosmetic use only) Operation Cautions Warning Do not point the probe directly at the eyeball, touch the eye or massage the upper eyelid. It is forbidden for the following groups : Pregnant women and those equipped with a cardiac chronometer; Tumor patients and serious heart disease;...
Page 15
Ultrasonic probe (Cosmetic use only) 1. Return to main interface 2. Reducing Energy Level Energy level range:1~10 3. Energy Level Display 4. Increasing Energy Level Energy level range:1~10 5. Working time display The working time enters the countdown when operating. The machine will stop automatically when the time shows zero.
Function Introduction Skin Scrubber Operation Cautions Warning Do not touch the output interface of Skin Scrubber alone when the host is powered on. Do not put the Scrubber directly in contact with the eye. It is prohibited for the following people: Allergic patients;...
Page 17
Skin Scrubber 1. Return to main interface 2. Reducing Energy Level Energy level range: 1~10 3. Energy Level Display 4. Increasing Energy Level Energy level range: 1~10 5. Working time display The working time enters the countdown when operating. The machine will stop automatically when the time shows zero. 6.
Function Introduction Radio Frequency Operation Cautions Warning Please use the product at the rated voltage conforming to the product and ensure that the plug is fully inserted, otherwise electric shock or fire may occur. Do not use it in the bathroom or in a damp room as it may cause electric shock or fire. Do not use in paint, coating, oxygen supply and other flammable and explosive places.
Page 19
Radio Frequency 1. Return to main interface 2. Reducing Energy Level Energy level range: 1~10 3. Energy Level Display 4. Increasing Energy Level Energy level range: 1~10 5. Working Time Display The working time enters the countdown when operating. The machine will stop automatically when the time shows zero. 6.
Page 20
Function Introduction Dermabrasion Operation Cautions Warning This function is not applicable to patients with hypertension, heart disease and diabetes. Pregnant women, lactation women, menstrual women should not be used. It is prohibited for use by patients with infectious diseases and cancer. Botox is banned for people who have received injections within a year.
Page 21
Dermabrasion 1. Return to main interface 2. Reducing Energy Level Energy level range:1~10 3. Energy Level Display 4. Increasing Energy Level Energy level range:1~10 5. Working Time Display The working time enters the countdown when operating. The machine will stop automatically when the time shows zero. 6.
Page 22
Function Introduction Sprayer Suction Operation Cautions Warning Do not operate suction function on eyes and surrounding skin. The following people are prohibited to use suction and spray functions: Allergic patients; Skin burns, scalds, sunburn, inflammation or other wounds. Attention If there is no suction when the machine is started, it is a normal phenomenon. Wait for a moment and it can be restored to normal.
Page 23
Sprayer Suction 1. Return to main interface 2. Reducing Energy Level Energy level range: 1~10 3. Energy Level Display 4. Increasing Energy Level Energy level range: 1~10 5. Working Time Display The working time enters the countdown when operating. The machine will stop automatically when the time shows zero. 6.
Page 24
Function Introduction High frequency electrotherapy Operation Cautions Warning It is forbidden to touch the output interface of the main machine of the high-frequency electrotherapy beauty instrument or the output interface of the handle of the high-frequency electrotherapy when the main machine is powered on. Do not point the tube directly or in contact with the eyes area.
Page 25
High frequency electrotherapy 1. Return to main interface 2. Reducing Energy Level Energy level range:1~10 3. Energy Level Display 4. Increasing Energy Level Energy level range:1~10 5. Working Time Display The working time enters the countdown when operating. The machine will stop automatically when the time shows zero. 6.
Function Introduction Rotary brush Operation Cautions Warning Do not operate under the eyes. The following groups are forbidden to use the brush function: Allergic patients; Skin burns, scalds, sunburn, inflammation or other wounds. Attention Before use, check whether the brush head is firmly inserted into the brush handle. Do not use the brush while holding the main brush head.
Page 27
Rotary brush 1. Return to main interface 2. Reducing Energy Level Energy level range: 1~10 3. Energy Level Display 4. Increasing Energy Level Energy level range: 1~10 5. Working Time Display The working time enters the countdown when operating. The machine will stop automatically when the time shows zero. 6.
Page 28
Function Introduction Galvanic roller bar Galvanic hand-held stick Operation Cautions Warning Do not operate the roller directly to the eyeball or directly contact the eye. It is forbidden to use this product for the following people and parts: Pregnant women and those with metal substances in their bodies; Allergic patients and tumor patients;...
Page 29
Galvanic roller bar Galvanic hand-held stick 1. Return to main interface 2. Reducing Energy Level Energy level range: 1~10 3. Energy Level Display 4. Increasing Energy Level Energy level range: 1~10 5. Working Time Display The working time enters the countdown when operating. The machine will stop automatically when the time shows zero.
Function Introduction RES mode CAP mode Negative Plate Operation Cautions Warning This function is not suitable for patients with hypertension, heart disease and diabetes Not suitable for lactating women and menstruating women. It should not be used by patients with infectious diseases or tumors. The function should not be used for any purpose other than cosmetic.
Page 31
RES mode 1. Return to the main interface 2. Real-time power display handle and negative plate form a loop to display the actual output power. 3. Output range display Displays the set range from 0 ~ 100. 4. Working time display When starting work, the working time enters the countdown.
Page 32
CAP mode 1. Return to the main interface 2. Real-time power display Handle and negative plate form a loop to display the actual output power. 3. Output range display Displays the set range from 0 to 100. 4. Working time display When starting work, the working time enters the countdown.
Troubleshooting The Fault Phenomenon Reason Solution 1. Check whether the fuse in the fuse bin in the power base is burned out. If burn out, replace the corresponding specificati 1. No power. The main machine ons of the new fuse. does not work or 2.
Need help?
Do you have a question about the F-362 and is the answer not in the manual?
Questions and answers