SilverFox F-360 Manual

Microcrystal beauty instrument

Advertisement

Quick Links

Microcrystal
F-360
beauty instrument
Please read the instruction carefully before using the product

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the F-360 and is the answer not in the manual?

Questions and answers

Summary of Contents for SilverFox F-360

  • Page 1 Microcrystal F-360 beauty instrument Please read the instruction carefully before using the product...
  • Page 2: Product Description

    F-360 1. Warning 1. Cut off the power supply when replacing electrical components or maintaining and cleaning the machine. 2. Never leave machine unattended when power on . 3. It can only be used in accordance with the inherent use described in the instruction manual, and no accessories applied without recommendation by the manufacturer.
  • Page 3: Packing List

    F-360 5. Packing list Designation Specification parameter Quantity 1 piece AC 100-240V Mainframe Diamond Dermabrasion suction Note 1 1 set pen and grinding head 1 piece Microcrystal grinding rod 1 piece The waste sand bottle 1 piece Net sand bottle...
  • Page 4: Installation Instructions

    F-360 6.Installation instructions 1. As shown in photo 1, well connect the attachments of the mainframe P h o t o 1 (1) Mainframe (2) Microcrystal waste sand bottle (3) Microcrystalline pure sand bottle (4)Diamond Dermabrasion suction pen (5) Microcrystal Grinding rod...
  • Page 5 F-360 3. As left picture shown, the microcrystalline waste sand bottle and the microcrystalline clean sand bottle are respectively placed on the attachment rack. 4. As photos show, Diamond Dermabrasion filter , Microcrystalline filter and condensate water filter are respectively installed on the back board of the main engine in order;...
  • Page 6 F-360 Microcrystal Dermabrasion ① Return to standby ⑥Timing: minute screen Key display ②Digital display of ⑦Time increase key energy gear position ③Energy gears ⑧Time decrease key display bar ④Energy decrease ⑨Start/stop buttons ⑤Energy increase ⑩ “Pipe cleaning” Button Photo 3 ①...
  • Page 7 F-360 4. Microcrystal Dermabrasion function Diamond Dermabrasion ① Return to Standby ⑥Timing : screen Key Minute display ②Energy increase ⑦Time increase ③Energy decrease ⑧Time decrease ④Energy gears ⑨Start/stop display bar buttons ⑤Digital display of energy gears Photo 4 ① Button :return to standby screen , click once to return to standby screen ②...
  • Page 8: Daily Maintenance

    F-360 Deep treatment after 2~3 days , it will appear the itching peeling phenomenon , please do make good hydration replenishment. After skin grinding, please try to use mild maintenance products, not acid metabolites. 3. please u use microcrystalline sand is 180#~200# mesh. The recycled waste sand is not allowed to be use again.
  • Page 9 F-360 2) Clean the filter A) Pour out the water or impurities inside the cup cover of filter;If cleaning is needed, the filter can be rinsed under the faucet. It is strictly prohibited to use corrosive liquid such as alcohol. Dry it after cleaning or wipe it with dry soft cloth or dry paper towel.
  • Page 10 F-360 4)Clean the white microcrystalline filter core (Photo 10 & 11), outer surface of tube and inner surface of bottle cap with a dry soft brush.(note: dust cannot be allowed to enter the trachea interface shown in photo 12 during the cleaning . The trachea cannot be washed with water. If make it wet carelessly , must wait for the...
  • Page 11 F-360 5. Cleaning of sand bottles : (method similar to waste sand bottles) 1)Prepare a soft and exquisite brush ,See photo 19. P h o t o 19 2)Remove the clear sand bottle from the machine, See photo 20 Photo 20 3)Open the bottle caps at both ends and remove the sealed silicone ring inside the lid, see photo 21.
  • Page 12 F-360 6) When installing the bottle, please note that the two large silicone sealing rings in photo 23 are the same size . To distinguish the upper and lower surfaces, please refer to photo 24 and 25. The flat side is upward.
  • Page 13 F-360 8) Check whether the two sealing rings between the microcrystal plastic cap and the micro-crystal pen are good. 9) Contact agents or manufacturers for further analysis and processing. 1) Check whether the air pump is working and whether the gear adjustment is normal.

Table of Contents