Toshiba RAS-24E2AVG-E Installation Manual
Toshiba RAS-24E2AVG-E Installation Manual

Toshiba RAS-24E2AVG-E Installation Manual

R32 inverter

Advertisement

Quick Links

R32
INSTALLATION MANUAL
AIR CONDITIONER (SPLIT TYPE)
Scan QR CODE to access installation and owner's manual on website.
https://www.toshiba-carrier.co.th/manuals/default.aspx
Manual are available in EN/IT.
Indoor unit
RAS-B24S4KVG-E
Outdoor unit
RAS-24E2AVG-E
1133550135

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the RAS-24E2AVG-E and is the answer not in the manual?

Questions and answers

Summary of Contents for Toshiba RAS-24E2AVG-E

  • Page 1 INSTALLATION MANUAL AIR CONDITIONER (SPLIT TYPE) Scan QR CODE to access installation and owner’s manual on website. https://www.toshiba-carrier.co.th/manuals/default.aspx Manual are available in EN/IT. Indoor unit RAS-B24S4KVG-E Outdoor unit RAS-24E2AVG-E 1133550135...
  • Page 2: Accessory Parts

    ACCESSORY PARTS ACCESSORY PARTS Indoor Unit Part name Part name Installation plate × 1 Wireless remote controller × 1 Battery × 2 Remote controller holder × 1 Ultra Fresh fi lter × 2 Mounting screw × 6 Flat head wood screw × 2 Owner’s Manual ×...
  • Page 3: Installation Diagram Of Indoor And Outdoor Units

    INSTALLATION DIAGRAM OF INDOOR AND OUTDOOR UNITS INSTALLATION DIAGRAM OF INDOOR AND OUTDOOR UNITS For the rear left, bottom left and left piping Wall Hook Installation plate Cut out a piece of SPACER from indoor unit packaging box, roll it and insert between the indoor unit and wall to Flat head wood screw...
  • Page 4: Indoor Unit

    INDOOR UNIT INDOOR UNIT • Space allows for moving range of the air inlet grille and horizontal louver in Installation Place operation above curtain rails, window cornice or other objects. (Unit : mm) • A place which provides the spaces around the indoor unit as shown in the diagram •...
  • Page 5 For remote controller How to Connect Remote Controller for Wire Operation 1. Remove cover of remote controller by sliding down and take it out. 2. If batteries are exist, please take them out. The combination of using wire controller and batteries may cause of batteries explosion. 3.
  • Page 6 *Remark : 1. Recommend to use double insulation lead wire for connect In case of right or left piping remote controller and air conditioner. 2. For wire operation, 1 remote controller can control only • After scribing slits inside of the front 1 indoor unit.
  • Page 7: Indoor Unit Fixing

    Indoor Unit Fixing Drainage 1. Pass the pipe through the hole in the wall and hook the indoor unit on the 1. Run the drain hose sloped downwards. installation plate at the upper hook. NOTE 2. Swing the indoor unit to right and left to confi rm that it is fi rmly hooked up on the installation plate.
  • Page 8: Outdoor Unit

    • A place where high-frequency Strong • The allowable length of the connecting pipe. wind waves are likely to be generated as from audio equipment, welders, Models RAS-24E2AVG-E and medical equipment Chargeless Up to 15 m Maximum length 20 m Draining the Water...
  • Page 9 Tightening connection Pressure gauge Compound pressure gauge –101 kPa Align the centers of the connecting pipes and tighten the fl are nut as far as (–76 cmHg) possible with your fi ngers. Then tighten the nut with a spanner and torque Manifold valve wrench as shown in the fi...
  • Page 10 Packed valve handling precautions • Open the valve stem all the way out, but do not try to open it beyond the stopper. Pipe size of Packed Valve Size of Hexagon wrench 12.70 mm and smallers A = 4 mm 15.88 mm A = 5 mm Pump down process...
  • Page 11: Electrical Works

    ELECTRICAL WORKS ELECTRICAL WORKS The power supply can be selected to connect to indoor unit or outdoor unit. Choose proper way and connect the power supply and connecting cable by follow the instruction as following. Model RAS-B24S4KVG-E Power source 50Hz, 220 – 240V Single phase Maximum running current 12.00 A Circuit breaker rating...
  • Page 12: Power Supply And Connecting Cable Connection

    Power Supply and Connecting Cable Connection Power Supply Input at Outdoor Unit Terminal Block (Recommend) Indoor Unit Outdoor Unit Connecting cable Stripping length of the Connecting cable connect to 1 2 3 1 2 3 connecting cable Terminal block Earth line 50 mm 10 mm Earth line...
  • Page 13 Power supply input Wiring Diagram for 1:1 Outdoor Unit Power input at Outdoor Terminal Block (Recommend) Indoor Terminal Block Outdoor Terminal Block Power input Power input at Indoor Terminal Block (Optional) Indoor Terminal Block Power input Outdoor Terminal Block CAUTION 1.
  • Page 14 In Case of Indoor Unit Connect With Inverter Multi System (IMS) Indoor Unit Stripping length of the Connecting cable Connecting cable connect to 1 2 3 connecting cable Terminal block Earth line 50 mm 10 mm 10 mm 70 mm Earth line Connecting cable...
  • Page 15: Test Operation

    OTHERS OTHERS Gas Leak Test Test Operation To switch the TEST RUN (COOL) mode, press [RESET] button for 10 seconds. (The beeper will make a short beep.) Check places for the indoor unit. OPERATION / RESET Button Check places for the outdoor unit.
  • Page 20 1133550135...