fluidra Sunblazer SBHC130 Installation And Operation Manual

Ultra heat/cool pool/spa heat pump

Advertisement

Quick Links

Sunblazer Ultra Heat/Cool Pool/Spa Heat Pump
Model: SBHC130
FOR YOUR SAFETY – This product must be installed and serviced by a contractor
who is licensed and qualified in pool equipment by the jurisdiction in which the
product will be installed where such state or local requirements exist. The
maintainer must be a professional with sufficient experience in pool equipment
installation and maintenance so that all of the instructions in this manual can be
followed exactly. Before installing this product, read and follow all warning notices
and instructions that accompany this product. Failure to follow warning notices and
instructions may result in property damage, personal injury, or death. Improper
installation and/or operation may void the warranty.
Improper installation and/or operation can create unwanted electrical hazard which
may cause serious injury, property damage, or death.
ATTENTION INSTALLER – This manual contains important information
about the installation, operation and safe use of this product.
This information should be given to the owner/operator of this
equipment.
Installation and Operation Manual
WARNING

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Sunblazer SBHC130 and is the answer not in the manual?

Questions and answers

Summary of Contents for fluidra Sunblazer SBHC130

  • Page 1 Installation and Operation Manual Sunblazer Ultra Heat/Cool Pool/Spa Heat Pump Model: SBHC130 WARNING FOR YOUR SAFETY – This product must be installed and serviced by a contractor who is licensed and qualified in pool equipment by the jurisdiction in which the product will be installed where such state or local requirements exist.
  • Page 2: Table Of Contents

    ENGLISH Sunblazer Ultra Heat/Cool Pool/Spa Heat Pump | Installation & Operation Manual ® Table of Contents Section 1. Important Safety Instructions ... 3 Section 7. General Maintenance ....10 7.1 Water Chemistry ........10 Section 2. System Information ....4 7.2 Cleaning ..........
  • Page 3: Section 1. Important Safety Instructions

    ENGLISH Sunblazer Ultra Heat/Cool Pool/Spa Heat Pump | Installation & Operation Manual ® Section 1. Important Safety Instructions READ AND FOLLOW ALL INSTRUCTIONS Sunblazer Heat/Cool heat pumps are designed and manufactured to provide many years of safe and reliable service when installed, operated and maintained according to the information in this manual and the installation codes referred to in later sections.
  • Page 4: Section 2. System Information

    ENGLISH Sunblazer Ultra Heat/Cool Pool/Spa Heat Pump | Installation & Operation Manual ® Section 2. System Information Section 3. Installation Materials Needed for Installation Location Recommendations The following items are needed and are to be supplied • Make sure the heat pump is not located where by the installer for all heat pump installations: large amounts of water may enter the heater.
  • Page 5: Anchor Clamps

    ENGLISH Sunblazer Ultra Heat/Cool Pool/Spa Heat Pump | Installation & Operation Manual ® produces 3 to 5 gallons of water per hour. When the heater is shut off for a period of time, the water created from condensation will evaporate. Heat Pump Anchor Clamps...
  • Page 6: Check Valve Installation

    ENGLISH Sunblazer Ultra Heat/Cool Pool/Spa Heat Pump | Installation & Operation Manual ® 3-Way Changeover Skimmer Manual Valve Bypass Main Pool Return AquaPure ® Heater Main Drains Manual Bypass Detail (Suction Outlet) Manual Bypass is Used When Filtration Rate Exceeds 70 GPM Check 3-Way Spa Drain...
  • Page 7: Bonding

    ENGLISH Sunblazer Ultra Heat/Cool Pool/Spa Heat Pump | Installation & Operation Manual ® Service Access Panel (3 Screws) Access for Electrical Wires Bonding Lug Figure 4. Sunblazer Heat/Cool Heat Pump Front Access Panel 9. Connect the ground wire to the ground lug 5.1.1 Disconnect Means provided in the electrical compartment.
  • Page 8: Wiring Diagram

    ENGLISH Sunblazer Ultra Heat/Cool Pool/Spa Heat Pump | Installation & Operation Manual ® Wiring Diagram High Voltage Legend Field Connection Red Wire Comp Compressor 208-230/1/60 Use for 208 V 220-240/1/50 Compressor Capacitor Application EVAP Defrost Temp. Sensor Black Fan Capacitor Fan Motor High Pressure Switch Orange - 230V Water Temp.
  • Page 9: Section 6. Heat Pump Operation / Digital Control Operation

    ENGLISH Sunblazer Ultra Heat/Cool Pool/Spa Heat Pump | Installation & Operation Manual ® Section 6. Heat Pump Operation / Digital Control Operation Initial Startup Pool/Spa Modes Before starting the heater for the first time, it is The control is equipped with two independent important to verify that the dedicated circuit breaker thermostats, one for pool temperature and one for and/or the service disconnect are in the “ON”...
  • Page 10: Changing The Set Point Temperature

    ENGLISH Sunblazer Ultra Heat/Cool Pool/Spa Heat Pump | Installation & Operation Manual ® Changing the Set Point Temperature • Defrosting applies in pool and spa heat modes. • Defrosting occurs when evaporator sensor reading To change the set point temperature: is below 24°F (-4°C).
  • Page 11: Cleaning

    ENGLISH Sunblazer Ultra Heat/Cool Pool/Spa Heat Pump | Installation & Operation Manual ® Cleaning Inspection Sunblazer heat pumps are designed and constructed CAUTION to provide long performance life when installed and operated properly under normal conditions. Periodic Make sure all power is disconnected to the heater inspections are important to keep your heat pump running safely and efficiently through the years.
  • Page 12: Section 8. Service Information

    If the water is still running out, call factory evaporator coil. Internal water leak. for service. 2882 Whiptail Loop # 100, Carlsbad, CA 92010, USA | 1.800.822.7933 ©2024 Fluidra. All rights reserved. The trademarks and trade names used herein are the property of their respective owners. H0883200_REVA...

Table of Contents