Download Print this page
fluidra Astralpool Viron P320 XT Installation And Operating Instructions Manual

fluidra Astralpool Viron P320 XT Installation And Operating Instructions Manual

Pool and spa pumps

Advertisement

Quick Links

INSTALLATION AND OPERATING INSTRUCTIONS
I
INSTALLATION AND OPERATING INSTRUCTIONS
Viron P320 XT
Viron Cartridge Filter
Viron P520 XT
Pool and Spa Pumps
Bolero ND Cleaner
INSTALLATION AND
OPERATING INSTRUCTIONS
sales@astralpool.com.au
www.astralpool.com.au
9/08/2017

Advertisement

loading

Summary of Contents for fluidra Astralpool Viron P320 XT

  • Page 1 INSTALLATION AND OPERATING INSTRUCTIONS INSTALLATION AND OPERATING INSTRUCTIONS Viron P320 XT Viron Cartridge Filter Viron P520 XT Pool and Spa Pumps Bolero ND Cleaner INSTALLATION AND OPERATING INSTRUCTIONS sales@astralpool.com.au www.astralpool.com.au 9/08/2017...
  • Page 2 Serious injury or death may occur if this product is not used, operated or installed according to these instructions and relevant Australian standards. THIS APPLIANCE IS NOT INTENDED FOR USE BY YOUNG CHILDREN OR INFIRM PERSONS. PLEASE ENSURE YOUNG CHILDREN ARE SUPERVISED SO THAT THEY DO NOT PLAY WITH THE APPLIANCE. PUMP PRODUCES HIGH PRESSURES –...
  • Page 3: Installation

    FEATURES Continuous duty rated motor Precision reinforced moulded high head impeller, giving extra performance Single piece moulded body for added strength and longer life Rapid priming diffuser quickly corrects loss of water flow Quick and easy disassembly for servicing Large capacity basket with easily removed ramp on lid Ability to adjust factory pre-set speeds for optimum water flow and maximum energy savings for your pool and its equipment.
  • Page 4: Operation

    F. All pumps will operate quieter and perform more efficiently if a straight length of 450mm pipe is plumbed horizontally into the front of the pump. G. Water temperature not to exceed 45 degrees H. Pumps must be either - supplied by an isolating transformer, or - supplied through a residual current device (RCD) with a rated residual operating current not exceeding 30mA.
  • Page 5 SELECTION OF APPROPRIATE SPEEDS General Rules:  The total volume of water in your pool should be turned over at least once a day.  If operating for longer periods of time, you may be able to turn the output of your salt chlorinator to a lower level. Check your chlorine level frequently to ensure you do not over or under chlorinate your swimming pool.
  • Page 6 OPERATION OF CONTROL PANEL – VIRON P320 XT & P520 XT The Viron P320 and P520 XT pumps incorporate an LCD backlit screen with the following features: In built time clock:  Programmable for up to four timer periods each day ...
  • Page 7 OPERATION OF CONTROL PANEL – VIRON P320 & P520 XT (CONT…) Using the in built timer to operate pump with an AstralPool Chlorinator or EQ dosing unit Factory Default Setting 1. The inbuilt timers are activated and will control the time the pump operates 2.
  • Page 8 11. When cycling through the Menu button TMR will no longer appear 12. You will no longer be able to automatically have the speed of the pump changed during different times of the day. 13. However, if you wish for a period where the pump operates at a high speed, for example to circulate the water vigorously for a part of the daily filtration, you can use the PRIMING setting to do so.
  • Page 9 REMOTE CONTROL OF SPEEDS AND TIMER FUNCTIONS • Viron XT pump stand alone • 4 built in timer periods in pump • 3 programmable speed settings • Low, medium or high speed can be selected in each timer period • Priming period can be selected from 2 to 120 minutes •...
  • Page 10 240v power 24v data SPEED SELECTION EXAMPLES FOR VIRON P520 XT Function Speed Vacuuming Pool or Spa Medium Speed (high speed may collapse vacuum hose) Operating Spa Jets Medium or High Speed Operating Waterfall or Water Feature Medium Speed or High Speed, depending on effect required Cleaning up pool with Cloudy Water Up to 24 hours on High Speed...
  • Page 11 USE WITH ASTRALPOOL GAS HEATERS Gas heaters (and electric heat pumps) generally rely on a water pressure switch to activate the heater control circuit. When a variable speed pump operates on low speed the water pressure produced in generally insufficient to activate the pressure switch and control circuit within the heater.
  • Page 12: Maintenance

    MAINTENANCE Maintenance Schedule: You new product incorporates moving parts and withstands high velocity water with chemicals in it. Some of these parts will wear in the normal course of use and require regular checks and maintenance. Performing these checks and maintenance will identify parts that have worn and require repair/replacement before further serious damage is sustained.
  • Page 13 VIRON XT CONTROL FLOW DIAGRAM Inst.434 Viron XT Pool & Spa Pump V08_17...
  • Page 14: Warranty

    WARRANTY AstralPool Australia Pty Ltd (ABN 97 007 284 504) ("AstralPool") provides the following warranty in relation to its Viron XT series Pool and Spa pumps ("Product"). The benefits of this warranty are in addition to any rights and remedies imposed by Australian State and Federal legislation that cannot be excluded.
  • Page 15 LIMITATIONS AstralPool makes no express warranties or representations other than set out in this warranty. The repair or replacement of the Product or part of the Product is the absolute limit of AstralPool's liability under this express warranty. This warranty is subject to the conditions and limitations listed herein. All warranties apply to the original purchaser of the product and are not transferable to new owners.
  • Page 16 INSTALLATION AND OPERATING INSTRUCTIONS INSTALLATION AND OPERATING INSTRUCTIONS INSTALLATION AND OPERATING INSTRUCTIONS INSTALLATION AND OPERATING INSTRUCTIONS Inst.434 Viron XT Pool & Spa Pump V08_17...

This manual is also suitable for:

Astralpool viron p520 xt