Wasp WDI4200 Product Reference Manual

2d usb barcode reader
Hide thumbs Also See for WDI4200:
Table of Contents

Advertisement

Quick Links

Wasp WDI4200
2D USB Barcode Reader
Product Reference Guide

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the WDI4200 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Wasp WDI4200

  • Page 1 Wasp WDI4200 2D USB Barcode Reader Product Reference Guide...
  • Page 2 Wasp Technologies representative. Electronic versions may either be downloadable from the Wasp Technologies website (www.waspbarcode.com) or provided on appropriate media. If you visit our website and would like to make comments or suggestions about this or other Wasp Technologies pub- lications, please let us know via the "Contact WaspTechnologies" page.
  • Page 3: Table Of Contents

    Table of Contents INTRODUCTION ....................................1 About the Scanner ......................................1 Using the WDI4200 Reader ..........................................1 About this Manual ......................................2 Overview ..................................................2 Manual Conventions ............................................. 3 Technical Support ......................................3 Wasp Website Support ............................................3 Reseller Technical Support ..........................................3 Telephone Technical Support ..........................................
  • Page 4 Standard Factory Settings for Symbologies ............................113 Disable All Symbologies ....................................114 Coupon Control ......................................114 UPC-A ...........................................115 UPC-A Enable/Disable ............................................115 UPC-A Check Character Transmission ......................................115 Expand UPC-A to EAN-13 ..........................................116 UPC-A Number System Character Transmission ..................................116 UPC-E ...........................................118 WDI4200...
  • Page 5 Contents UPC-E Enable/Disable ............................................118 UPC-E Check Character Transmission ......................................118 Expand UPC-E to EAN-13 ..........................................119 Expand UPC-E to UPC-A ..........................................119 UPC-E Number System Character Transmission ..................................120 EAN 13 .........................................121 EAN 13 Enable/Disable ............................................ 121 EAN 13 Check Character Transmission ...................................... 121 EAN-13 Flag 1 Character ..........................................
  • Page 6 IATA Check Character Transmission ......................................183 ISBT 128 ........................................184 ISBT 128 Concatenation ..........................................184 ISBT 128 Concatenation Mode ........................................184 ISBT 128 Dynamic Concatenation Timeout ..................................... 185 ISBT 128 Force Concatenation ........................................186 ISBT 128 Advanced Concatenation Options .................................... 186 MSI ..........................................187 WDI4200...
  • Page 7 Contents MSI Enable/Disable ............................................187 MSI Check Character Calculation ......................................... 187 MSI Check Character Transmission ......................................188 MSI Length Control ............................................188 MSI Set Length 1 ..............................................189 MSI Set Length 2 ..............................................190 Code 93 ........................................191 Code 93 Enable/Disable ..........................................191 Code 93 Check Character Calculation ......................................
  • Page 8 Control Character Emulation ..................................289 Single Press and Release Keys ........................................289 Interface Type PC AT PS/2 or USB-Keyboard ............................290 Interface Type PC AT PS/2 Alt Mode or USB-Keyboard Alt Mode ......................292 Microsoft Windows Codepage 1252 .................................294 Index ..................................295 WDI4200...
  • Page 9: Introduction

    Introduction About the Scanner The WDI4200 area imager is an entry level product specifically designed for reading long and truncated 1D codes and larger 2D codes from close distance. The WDI4200 imager has an extra-wide Field of View which captures these...
  • Page 10: About This Manual

    Appendix C, Sample Bar Codes offers sample bar codes of several common sym- bologies. Appendix D, Keypad includes numeric bar codes to be scanned for certain parameter settings. Appendix E, Scancode Tables lists control character emulation information for Wedge and USB Keyboard interfaces. WDI4200...
  • Page 11: Manual Conventions

    Telephone Technical Support If you do not have internet or email access, you may contact Wasp at +1 214- 547-4100. Current versions of the Product Reference Guide (PRG), Quick Reference Guide (QRG), software/firmware and any additional manuals, instruction sheets and utilities for this product can be downloaded from the website.
  • Page 12 Introduction NOTES WDI4200...
  • Page 13: Setup

    Chapter 2 Setup Unpacking Check carefully to ensure the scanner and any cables or accessories ordered are present and undamaged. If any damage occurred during shipment, contact Technical Support on page 3. KEEP THE PACKAGING. Should the unit ever require service, it should be returned in its original shipping container.
  • Page 14: Connect Host Interface

    Select to communicate either by USB OEM, USB COM STD, or USB Keyboard USB : interface types by scanning the appropriate interface type bar codes available in this manual. The default interface is USB-KBD, or RS-232-STD. WDI4200...
  • Page 15 Setting Up the Scanner Figure 3. Connection to the Host WEDGE RS-232 Specific cables are required for connection to different hosts. The connec- tions illustrated in Figure 3 are examples only. Actual connectors may vary from those illustrated, but the steps to connect the scanner remain the NOTE same.
  • Page 16: Stand Installation

    Figure 5. Adjusting the Stand This accessory can also be used as a holder to mount the reader on a wall or other vertical position as shown in Figure Figure 6. Using the Wall Holder WDI4200...
  • Page 17: Using The Wdi4200

    Using the WDI4200 Using the WDI4200 The WDI4200 normally functions by capturing and decoding codes. The aiming system is activated on trigger pull and indicates the center of the field of view which should be positioned over the bar code:...
  • Page 18 If the aiming system is centered you will get a good read. Successful reading is signaled by an audible tone plus a goodread green spot LED indicator. Relative Size and Location of Green Spot WDI4200...
  • Page 19: Interface Selection

    Interface Selection Interface Selection Upon completing the physical connection between the scanner and its host, proceed directly to "Configuring the Interface" on page 11 for information and programming for the interface type the scanner is connected to (for example: RS-232, Keyboard Wedge, USB, etc.) and scan the appropriate bar code in that section to select your system’s correct interface type.
  • Page 20 (can be used for OPOS/UPOS/JavaPOS) starting on page 67 Select USB-OEM USB-COMPOSITE FEATURES $P,HA45,P Set USB-OEM Interface USB-Composite Features (combines USB-KBD emulation and USB-COM) starting on page 67 Select USB-Composite a. Download the correct USB Com driver from www.waspbarcode.com WDI4200...
  • Page 21 Interface Selection KEYBOARD FEATURES $P,HA29,P  AT, PS/2 25-286, 30-286, 50, 50Z, 60, 70, 80, 90 & 95 w/Standard Key Encoding Select KBD-AT $P,HA11,P  Keyboard Wedge for IBM AT PS2 with standard key encoding but without external keyboard Select KBD-AT-NK $P,HA26,P ...
  • Page 22: Customizing Configuration Settings

    • RS-232 ONLY Interface, starting on page 21 • RS-232/USB-COM Interfaces, starting on page 25 • RS232 OPOS • USB Composite (COM + Keyboard) • Keyboard Interface, starting on page 35 • USB-OEM Interface, starting on page 67 WDI4200...
  • Page 23: Configuring Other Features

    Customizing Configuration Settings Configuring Other Features If your installation requires different programming than the standard factory default settings, the following sections of this manual allow configuration of non-interface-specific settings you might require: Configuration Using Bar Codes General Features includes programming for scan- ning, speaker and LED indicators and other such universal settings.
  • Page 24 CAUTION Restore USA Factory Configuration Restore EU Factory Configuration The programming section on the following pages lists the factory default set- tings for each of the menu commands (indicated by shaded blocks and bold text). WDI4200...
  • Page 25: Configuration Using Bar Codes

    Chapter 3 Configuration Using Bar Codes This and following sections provide programming bar codes to configure your scanner by changing the default settings. For details about additional methods of programming, see "Customizing Configuration Settings" on page You must first enable your scanner to read bar codes in order to use this section.
  • Page 26 You can then start again at the beginning. 4. Complete the programming sequence by scanning the ENTER/EXIT PRO- GRAMMING bar code to exit Programming Mode. For more detailed descriptions, programming information and examples for setting selected configuration items, see References, starting on page 233. WDI4200...
  • Page 27: Global Interface Features

    Configuration Using Bar Codes Enter/Exit Programming Mode Global Interface Features The following interface features are configurable by all interface types. To set features specific to your interface, turn to that section of this manual. on page 19 — O OMMANDS GNORE on page 20 USB S...
  • Page 28: Usb Suspend Mode

    Enter/Exit Programming Mode Global Interface Features USB Suspend Mode This setting enables/disables the ability of the USB interface to enter suspend mode. $CUSSE00  USB Suspend Mode = Disable $CUSSE01  DEFAULT USB Suspend Mode = Enable WDI4200...
  • Page 29: Only Interface

    RS-232 ONLY Interface Enter/Exit Programming Mode RS-232 ONLY Interface Use the programming bar codes in this chapter if modifications to the standard RS-232 interface settings are necessary to meet your system’s requirements. Additional settings which apply to both the RS-232 and USB interfaces are available in Chapter 5, RS-232/USB-COM Interfaces.
  • Page 30: Data Bits

     Baud Rate = 115,200 Data Bits This parameter allows the reader to interface with devices requiring a 7-bit or 8-bit ASCII protocol for sending and receiving data.  $CR2ST00 7 Data Bits $CR2ST01  DEFAULT 8 Data Bits WDI4200...
  • Page 31: Stop Bits

    RS-232 ONLY Interface Enter/Exit Programming Mode Stop Bits The stop bit(s) at the end of each transmitted character marks the end of trans- mission of one character and prepares the receiving device for the next charac- ter in the serial data stream. The number of stop bits selected (one or two) depends on the number the receiving terminal is programmed to accommo- date.
  • Page 32: Handshaking Control

    $CR2HC00  DEFAULT Handshaking Control = RTS $CR2HC01  Handshaking Control = RTS/CTS $CR2HC02  Handshaking Control = RTS/XON/XOFF $CR2HC03  Handshaking Control = RTS On/CTS $CR2HC04  Handshaking Control = RTS/CTS Scan Control WDI4200...
  • Page 33: Rs-232/Usb-Com Interfaces

    RS-232/USB-COM Interfaces Enter/Exit Programming Mode RS-232/USB-COM Interfaces The programming bar codes in this chapter allow modifications to the standard RS-232 and USB-Com interfaces. on page 25 TANDARD ACTORY ETTINGS on page 26 NTERCHARACTER ELAY on page 27 ASCII BEL on page 27 OT ON on page 28 ACK NAK O...
  • Page 34: Intercharacter Delay

    ENTER/EXIT bar code again. Select Intercharacter Delay Setting Make a mistake? Scan the CANCEL bar code to abort and not save the entry string. You can then start again at the beginning. CANCEL 00 = No Intercharacter Delay DEFAULT WDI4200...
  • Page 35: Beep On Ascii Bel

    RS-232/USB-COM Interfaces Enter/Exit Programming Mode Beep On ASCII BEL When this parameter is enabled, the scanner issues a beep when a <BEL> char- acter is detected on the RS-232 serial line. <BEL> is issued to gain a user's attention to an illegal entry or other important event. $CR2BB00 ...
  • Page 36: Ack Nak Options

     $CR2AE00 DEFAULT ACK/NAK Protocol = Disable ACK/NAK $CR2AE01  ACK/NAK Protocol = Enable for label transmission $CR2AE02  ACK/NAK Protocol = Enable for host-command acknowledge $CR2AE03  ACK/NAK Protocol = Enable for label transmission and host- command acknowledge WDI4200...
  • Page 37: Ack Character

    RS-232/USB-COM Interfaces Enter/Exit Programming Mode ACK Character This setting specifies an ASCII character or hex value to be used as the ACK character. ASCII characters or any hex value from 0 to 0xFF can be selected. See "ACK Character" on page 236 for more detailed programming instructions. Setting to previously defined characters such as XON, XOFF, or host commands conflicts with normal operation of these char- acters.
  • Page 38: Ack Nak Timeout Value

    Select ACK NAK Timeout Value Setting Make a mistake? Scan the CANCEL bar code to abort and not save the entry string. You can then start again at the beginning. CANCEL 01 ACK NAK Timeout value is 200ms DEFAULT WDI4200...
  • Page 39: Ack Nak Retry Count

    RS-232/USB-COM Interfaces Enter/Exit Programming Mode ACK NAK Retry Count This feature specifies the number of times the scanner retries a label transmis- sion due to a retry condition. The selectable range is from 1 to 254 retries. A selection of 0 disables the count, and a selection of 255 specifies unlimited retries.
  • Page 40: Ack Nak Error Handling

    Process error as valid NAK character $CR2EH00  DEFAULT ACK NAK Error Handling = Ignore Errors Detected  $CR2EH01 ACK NAK Error Handling = Process Error as Valid ACK Character $CR2EH02  ACK NAK Error Handling = Process Error as Valid NAK Character WDI4200...
  • Page 41: Indicate Transmission Failure

    RS-232/USB-COM Interfaces Enter/Exit Programming Mode Indicate Transmission Failure This option enables/disables the scanner’s ability to sound an error beep to indicate a transmission failure while in ACK/NAK mode. $CR2TF00  Indicate Transmission Failure = Disable Indication $CR2TF01  DEFAULT Indicate Transmission Failure = Enable Indication Disable Character Specifies the value of the RS-232 host command used to disable the scanner.
  • Page 42: Enable Character

    NOTE $CR2EC Select Enable Character Setting 0x45 = Enable Character is ‘E’ DEFAULT Make a mistake? Scan the CANCEL bar code to abort and not save the entry string. You can then start again at the beginning. CANCEL WDI4200...
  • Page 43: Keyboard Interface

    Keyboard Interface Use the programming bar codes in this chapter to select options for USB Key- board and Wedge Interfaces. Reference Appendix B, for a listing of standard factory settings. Information about control character emulation which applies to keyboard interfaces is listed in Appendix E, Scancode Tables.
  • Page 44: Country Mode

    This feature specifies the country/language supported by the keyboard. The Country Mode setting is ignored if the interface uses alternate key encod- ing. Setup on PC to use ALT Universal 1. Open Registry Edit 2. Set EnableHexNumpad to 1 as follows: 3. Reset the PC. WDI4200...
  • Page 45: Setting Country Mode

    Keyboard Interface Enter/Exit Programming Mode Setting Country Mode $CKBCO00  DEFAULT United States $CKBCO01  French International (Belgian French) $CKBCO02  United Kingdom $CKBCO11  Danish $CKBCO0E  French (France) $CKBCO03  German $CKBCO04  Italian Product Reference Guide...
  • Page 46 Enter/Exit Programming Mode Country Mode Setting Country Mode (continued) $CKBCO0F  Norwegian $CKBCO09  Portuguese Portugal $CKBCO0A  Spanish $CKBCO0B  Swedish $CKBCO13  Swiss French $CKBCO14  Japanese ASCII  $CKBCO13 Hungarian WDI4200...
  • Page 47 Keyboard Interface Enter/Exit Programming Mode Setting Country Mode (continued) $CKBCO0F  Czech $CKBCO09  SlovaK $CKBCO0A  Romanian $CKBCO0B  Croatian $CKBCO13  Polish_214 $CKBCO14  Canadian French Win7  $CKBCO13 Lithuanian Product Reference Guide...
  • Page 48 Enter/Exit Programming Mode Country Mode Setting Country Mode (continued) $CKBCO0F  Vietnamese $CKBCO09  Russian $CKBCO0A  Arabic 101 $CKBCO0B  Chinese ASCII $CKBCO13  Thai-Kedmanee $CKBCO14  Albanian  $CKBCO13 Arabic 102 WDI4200...
  • Page 49 Keyboard Interface Enter/Exit Programming Mode Setting Country Mode (continued) $CKBCO0F  Arabic 102 AZERTY $CKBCO09  Azeri Cyrillic $CKBCO0A  Azeri Latin $CKBCO0B  Belarusian $CKBCO13  Bosnian Cyrillic $CKBCO14  Bosnian Latin  $CKBCO13 Bulgarian Cyrillic Product Reference Guide...
  • Page 50 Enter/Exit Programming Mode Country Mode Setting Country Mode (continued) $CKBCO0F  Bulgarian Latin $CKBCO09  Canadian French (Legacy) $CKBCO0A  Canadian Multilingual $CKBCO0B  Chinese (Simplified)  $CKBCO13 Chinese (Traditional) $CKBCO14  Czech Programmers $CKBCO13  Czech QWERTY WDI4200...
  • Page 51 Keyboard Interface Enter/Exit Programming Mode Setting Country Mode (continued) $CKBCO0F  Dutch Netherland $CKBCO09  Estonian $CKBCO0A  Faeroese $CKBCO0B  Finnish $CKBCO13  French (Canada) 2000/XP $CKBCO14  French (Canada) 95/98  $CKBCO13 Galician Product Reference Guide...
  • Page 52 Enter/Exit Programming Mode Country Mode Setting Country Mode (continued) $CKBCO0F  Greek $CKBCO09  Greek Latin $CKBCO0A  Greek Polytonic $CKBCO0B  Greek220 $CKBCO13  Greek220 Latin $CKBCO14  Greek319  $CKBCO13 Greek319 Latin WDI4200...
  • Page 53 Keyboard Interface Enter/Exit Programming Mode Setting Country Mode (continued) $CKBCO0F  Hebrew Israel $CKBCO09  Hungarian_101KEY $CKBCO0A  Icelandic $CKBCO0B  Irish $CKBCO13  Italian_142 $CKBCO14  Japanese (Shift-JIS)  $CKBCO13 Kazakh Product Reference Guide...
  • Page 54 Enter/Exit Programming Mode Country Mode Setting Country Mode (continued) $CKBCO0F  Korean (Hangul) $CKBCO09  Korean ASCII $CKBCO0A  Kyrgyz Cyrillic $CKBCO0B  Latin America $CKBCO13  Latvian $CKBCO14  Latvian QWERTY  $CKBCO13 Lithuanian_IBM WDI4200...
  • Page 55 Keyboard Interface Enter/Exit Programming Mode Setting Country Mode (continued) $CKBCO0F  Macedonian -FYROM $CKBCO09  Maltese_47KEY $CKBCO0A  Mongolian-Cyrillic $CKBCO0B  Polish Programmer  $CKBCO13 Portuguese Brazil  $CKBCO14 Portuguese Brazilian ABNT  $CKBCO13 Portuguese Brazilian ABNT2 Product Reference Guide...
  • Page 56 Enter/Exit Programming Mode Country Mode Setting Country Mode (continued) $CKBCO0F  Romanian Legacy $CKBCO09  Romanian Programmer $CKBCO0A  Romanian Standard $CKBCO0B  Russian Typewriter $CKBCO13  Serbian Cyrillic $CKBCO14  Serbian Latin  $CKBCO13 Slovak QWERTY WDI4200...
  • Page 57 Keyboard Interface Enter/Exit Programming Mode Setting Country Mode (continued) $CKBCO0F  Slovenian $CKBCO09  Spanish Variation $CKBCO0A  Swiss German $CKBCO0B  Tatar $CKBCO13  Turkish F $CKBCO14  Turkish Q $CKBCO13  Ukrainian Product Reference Guide...
  • Page 58 Country Mode Setting Country Mode (continued) $CKBCO0F  US Dvorak $CKBCO09  US Dvorak Left Hand $CKBCO0A  US Dvorak Right Hand $CKBCO0B  US English (Mac) $CKBCO13  US English (North American) $$CKBCO62 US International $$CKBCO63  Uzbek Cyrillic WDI4200...
  • Page 59: Setting Encoding Type

    Keyboard Interface Enter/Exit Programming Mode Setting Encoding Type $CKBCO00  DEFAULT Don’t use encoding $CKBCO01  UTF_8 $CKBCO02  Windows 874 $CKBCO11  Windows 932 $CKBCO0E  Windows 936 $CKBCO03  Windows 949 $CKBCO04  Windows 950 Product Reference Guide...
  • Page 60 Enter/Exit Programming Mode Country Mode Setting Encoding Type (continued) $CKBCO03  Windows 1250 $CKBCO09  Windows 1251 $CKBCO0A  Windows 1252  $CKBCO0B Windows 1253  $CKBCO13 Windows 1254 $CKBCO14  Windows 1255 $CKBCO13  Windows 1256 WDI4200...
  • Page 61 Keyboard Interface Enter/Exit Programming Mode Setting Encoding Type (continued) $CKBCO0F  Windows 1257 $CKBCO09  Windows 1258 $CKBCO0A  Windows 20866 $CKBCO0B  ISO 8859-1 $CKBCO13  ISO 8859-2 $CKBCO14  ISO 8859-3 $CKBCO13  ISO 8859-4 Product Reference Guide...
  • Page 62 Enter/Exit Programming Mode Country Mode Setting Encoding Type (continued) $CKBCO0F  ISO 8859-5  $CKBCO09 ISO 8859-6 $CKBCO0A  ISO 8859-7 $CKBCO0B  ISO 8859-8 $CKBCO13  ISO 8859-9 $CKBCO14  ISO 8859-10 $CKBCO13  ISO 8859-11 WDI4200...
  • Page 63 Keyboard Interface Enter/Exit Programming Mode Setting Encoding Type (continued) $CKBCO0F  ISO 8859-13 $CKBCO09  ISO 8859-14 $CKBCO0A  ISO 8859-15 $CKBCO0B  ISO 8859-16 $CKBCO13  MS-DOS 437 $CKBCO14  MS-DOS 737 $CKBCO13  MS-DOS 775 Product Reference Guide...
  • Page 64 Enter/Exit Programming Mode Country Mode Setting Encoding Type (continued) $CKBCO0F  MS-DOS 850 $CKBCO09  MS-DOS 852 $CKBCO0A  MS-DOS 855 $CKBCO0B  MS-DOS 857 $CKBCO13  MS-DOS 860 $CKBCO14  MS-DOS 861 $CKBCO13  MS-DOS 862 WDI4200...
  • Page 65 Keyboard Interface Enter/Exit Programming Mode Setting Encoding Type (continued) $CKBCO0F  MS-DOS 863 $CKBCO09  MS-DOS 865 $CKBCO0A  MS-DOS 866 $CKBCO0B  MS-DOS 869 $CKBCO13  Mac CP10000 Product Reference Guide...
  • Page 66: Setting Alt Output Type

    ALT mode & Normal Keyboard Scancode, to correctly display some characters that are not present in the current Keyboard Country). $CKBCO00  ALT Codepage: (use on non Unicode application: Notepad) $CKBCO01  DEFAULT ALT Unicode: (use on Unicode application: Word) $CKBCO02  ALT Universal: (Use for all) WDI4200...
  • Page 67: Caps Lock State

    Keyboard Interface Enter/Exit Programming Mode Caps Lock State This option specifies the format in which the scanner sends character data. This applies to Keyboard Wedge interfaces. This does not apply when an alternate key encoding keyboard is selected. This does not apply to USB Keyboard. $CKBCL00 ...
  • Page 68: Keyboard Numeric Keypad

    Keyboard Numeric Keypad Keyboard Numeric Keypad This feature specifies if numeric characters will be sent using the standard keys or the numeric keypad. $CKBKP00  DEFAULT Keyboard Numeric Keypad = Standard Keys $CKBKP01  Keyboard Numeric Keypad = Numeric Keypad WDI4200...
  • Page 69: Keyboard Send Control Characters

    Keyboard Interface Enter/Exit Programming Mode Keyboard Send Control Characters This feature is used by the Keyboard Wedge and USB Keyboard interfaces. It specifies how the scanner transmits ASCII control characters to the host. Refer- ence Appendix E, Scancode Tables for more information about control charac- ters.
  • Page 70: Wedge Quiet Interval

    ENTER/EXIT bar code again. Select Wedge Quiet Interval Setting Make a mistake? Scan the CANCEL bar code to abort and not save the entry string. You can then start again at the beginning. CANCEL 10 = Quiet Interval of 100 ms DEFAULT WDI4200...
  • Page 71: Intercharacter Delay

    Keyboard Interface Enter/Exit Programming Mode Intercharacter Delay This parameter specifies the intercharacter delay between the end of one char- acter and the beginning of the next. The delay can be set within a range of zero (0) to 990 milliseconds in 10ms increments. A setting of zero specifies no delay.
  • Page 72: Intercode Delay

    ENTER/EXIT bar code again. Set Intercode Delay Make a mistake? Scan the CANCEL bar code to abort and not save the entry string. You can then start again at the beginning. CANCEL 00 = No Wedge Intercode Delay DEFAULT WDI4200...
  • Page 73: Usb Keyboard Speed

    USB Keyboard Speed USB Keyboard Speed This option specifies the USB poll rate for a USB Keyboard. This feature applies ONLY to the USB Keyboard interface. NOTE $CKBSP01  DEFAULT USB Keyboard Speed = 1ms $CKBSP02  USB Keyboard Speed = 2ms ...
  • Page 74 Keyboard Interface NOTES WDI4200...
  • Page 75: Usb-Oem Interface

    USB-OEM Interface on page 67 NTRODUCTION on page 67 TANDARD ACTORY ETTINGS on page 68 USB-OEM D EVICE SAGE on page 68 USB-OEM I NTERFACE PTIONS Introduction Feature settings for USB interfaces differ depending upon which host type the scanner will be connected with. Use the feature settings in this chapter to spe- cifically configure for the USB-OEM interface.
  • Page 76: Usb-Oem Device Usage

    This setting provides for an interface specific control mechanism. Options are: • Obey — Obey Scanner Configuration Host Commands • Ignore — Ignore Scanner Configuration Host Commands $CIFO101  USB-OEM Interface Options = Obey $CIFO102  DEFAULT USB-OEM Interface Options = Ignore WDI4200...
  • Page 77: Data Format

    Data Format on page 70 LOBAL REFIX UFFIX on page 71 AIM ID LOBAL on page 71 GS1-128 AIM ID starting on page 72 ABEL Label ID: Pre-loaded Sets on page 72 • Label ID: Set Individually Per Symbology on •...
  • Page 78: Global Prefix/Suffix

    ENTER/EXIT bar code again. Set Global Suffix Make a mistake? Scan the CANCEL bar code to abort and not save the entry string. You can then start again at the beginning. CANCEL No Global Prefix DEFAULT Global Suffix = 0x0D(CR) WDI4200...
  • Page 79: Global Aim Id

    Data Format Enter/Exit Programming Mode Global AIM ID This feature enables/disables addition of AIM IDs for all symbology types. NOTE AIM label identifiers (as opposed to custom characters you select yourself as with label identifiers) can be included with scanned bar code data. See "Global AIM ID"...
  • Page 80: Label Id

    Any custom configuration or custom CAUTION defaults will be lost. $AE DEFAULT Label ID Pre-loaded Set = USA Set $Ae Label ID Pre-loaded Set = EU Set WDI4200...
  • Page 81: Label Id: Set Individually Per Symbology

    Data Format Enter/Exit Programming Mode Label ID: Set Individually Per Symbology This feature configures a Label ID individually for a single symbology. This setting requires the scanning of bar codes from multiple sections. See "Label ID: Set Individually Per Symbology" on page 250 for more detailed programming instructions.
  • Page 82: Label Id Symbology Selection

    You can then start again at the beginning. CANCEL $CABID Set UPC-A Label ID Character(s) $CA2ID Set UPC-A/P2 Label ID Character(s) $CA5ID Set UPC-A/P5 Label ID Character(s) $CEBID Set UPC-E Label ID Character(s) $CE2ID Set UPC-E/P2 Label ID Character(s) $CE5ID Set UPC-E/P5 Label ID Character(s) WDI4200...
  • Page 83 Data Format Enter/Exit Programming Mode Label ID Symbology Selection (continued) $C3BID Set EAN 13 Label ID Character(s) $C32ID Set EAN 13/P2 Label ID Character(s) $C35ID Set EAN 13/P5 Label ID Character(s) $C8BID Set EAN 8 Label ID Character(s) $C82ID Set EAN 8/P2 Label ID Character(s) $C85ID Set EAN 8/P5 Label ID Character(s) Product Reference Guide...
  • Page 84 Set GS1 DataBar Omnidirectional Label ID Character(s) $CXBID Set GS1 DataBar Expanded Label ID Character(s) $CLBID Set GS1 DataBar Limited Label ID Character(s) $CC3ID Set Code 39 Label ID Character(s) $CP3ID Set Code 32 Label ID Character(s) $CCCID Set Code 39 CIP Label ID Character(s) WDI4200...
  • Page 85 Data Format Enter/Exit Programming Mode Label ID Symbology Selection (continued) $CC8ID Set Code 128 Label ID Character(s) $CU8ID Set GS1-128 Label ID Character(s) $CI2ID Set Interleaved 2 of 5 Label ID Character(s) $CHRID Set Interleaved 2 of 5 CIP HR Label ID Character(s) $CD2ID Set Datalogic 2 of 5 CIP HR Label ID Character(s) $CCBID...
  • Page 86 Set Industrial 2 of 5 Label ID Character(s) $CINID Set ISSN Label ID Character(s) $CIAID Set IATA Label ID Character(s) $CI8ID Set Concatenated ISBT 128 Label ID Character(s) $CMSID Set MSI Label ID Character(s) $CC9ID Set Code 93 Label ID Character(s) WDI4200...
  • Page 87 Data Format Enter/Exit Programming Mode Label ID Symbology Selection (continued) $CF2ID Set Follett 2 of 5 Label ID Character(s) $CISID Set ISBN Label ID Character(s) $CI8ID Set Concatenated ISBT Label ID Character(s) Product Reference Guide...
  • Page 88: Case Conversion

    Case conversion affects ONLY scanned bar code data, and does not affect Label ID, Prefix, Suffix, or other appended data. NOTE $CLFCA00 DEFAULT Case Conversion = Disable (no case conversion) $CLFCA01 Case Conversion = Convert to upper case $CLFCA02 Case Conversion = Convert to lower case WDI4200...
  • Page 89: Character Conversion

    Character Conversion Character Conversion Character conversion is an eight byte configuration item. The eight bytes are 4 character pairs represented in hexadecimal ASCII values. The first character in the pair is the character that will be converted. The second character in the pair is the character to convert to.
  • Page 90 Data Format NOTES WDI4200...
  • Page 91: Reading Parameters

    Reading Parameters on page 84 on page 93 OUBLE IMEOUT CANNING EATURES on page 87 on page 93 PEAKER NDICATORS CANNING EATURES on page 87 on page 93 OWER LERT CANNING EATURES on page 88 on page 93 HEN TO NDICATE on page 88 on page 94...
  • Page 92: Double Read Timeout

    $CSNDR0A  Double Read Timeout = 0.1 Second $CSNDR14  Double Read Timeout = 0.2 Second $CSNDR1E  Double Read Timeout = 0.3 Second $CSNDR28  Double Read Timeout = 0.4 Second WDI4200...
  • Page 93 Reading Parameters Enter/Exit Programming Mode Double Read Timeout (continued) $CSNDR32  Double Read Timeout = 0.5 Second $CSNDR3C  DEFAULT Double Read Timeout = 0.6 Second $CSNDR46  Double Read Timeout = 0.7 Second $CSNDR50  Double Read Timeout = 0.8 Second $CSNDR5A ...
  • Page 94: Reading Performance

    Depth of field: increased performance for distant barcodes. Depending on specific environmental conditions or user's circumstances or expected performances, one may decide to assign a higher priority to one or the other. $CSNDR0A  Depth of field $CSNDR14  DEFAULT Motion tolerance WDI4200...
  • Page 95: Led And Speaker Indicators

    Reading Parameters Enter/Exit Programming Mode LED and Speaker Indicators Power On Alert Disables or enables the indication (from the Speaker) that the scanner is receiv- ing power. $CBPPU00  Power On Alert = Disable (No Audible Indication) $CBPPU01  DEFAULT Power On Alert = Power-up Beep Product Reference Guide...
  • Page 96: Good Read: When To Indicate

    This option, which uses CTS, is only valid for RS-232 interfaces. NOTE  $CBPIN00 DEFAULT Indicate Good Read = After Decode $CBPIN01  Indicate Good Read = After Transmit $CBPIN02  Indicate Good Read = After CTS Goes Inactive, Then Active WDI4200...
  • Page 97: Good Read Beep Type

    Reading Parameters Enter/Exit Programming Mode Good Read Beep Type Specifies whether the good read beep has a mono or bitonal beep sound. $CBPTY00  DEFAULT Good Read Beep Type = Mono $CBPTY01  Good Read Beep Type = Bitonal Good Read Beep Frequency Adjusts the good read beep to sound at a selectable low, medium or high fre- quency, selectable from the list below.
  • Page 98: Good Read Speaker Volume

    Selects the speaker volume (loudness) upon a good read beep. There are three selectable volume levels. $CBPVO00  Good Read Speaker Volume = Speaker Off $CBPVO01  Good Read Speaker Volume = Low $CBPVO02  Good Read Speaker Volume = Medium $CBPVO03  DEFAULT Good Read Speaker Volume = High WDI4200...
  • Page 99: Good Read Beep Length

    Reading Parameters Enter/Exit Programming Mode Good Read Beep Length Specifies the duration of a good read beep. $CBPLE06  Good Read Beep Length = 60 msec $CBPLE08  DEFAULT Good Read Beep Length = 80 msec $CBPLE0A  Good Read Beep Length = 100 msec $CBPLE0C ...
  • Page 100: Enable/Disable Good Read Indicator

    Good Read Beep Length = 180 msec $CBPLE14  Good Read Beep Length = 200 msec Enable/Disable Good Read Indicator Enable/Disable the good read indicator. $CRGBE00  Good Read Indicator = Disable $CRGBE01  DEFAULT Good Read Indicator = Enable WDI4200...
  • Page 101: Scanning Features

    Reading Parameters Enter/Exit Programming Mode Scanning Features Scan Mode "Scan Mode" on page 253 for more detailed programming instructions. $CSNRM00  DEFAULT Scan Mode = Trigger Single $CSNRM01  Scan Mode = Trigger Hold Multiple $CSNRM02  Scan Mode = Trigger Pulse Multiple $CSNRM03 ...
  • Page 102: Scanning Active Time

    CANCEL DEFAULT 005 = Scanning is active for 5 Seconds Stand Mode Flash Enables/disables the LED flash when the reader is in Stand Mode. $CSMFL00  DEFAULT Stand Mode Flash = Disable  $CSMFL01 Stand Mode Flash = Enable WDI4200...
  • Page 103: Flash On Time

    Reading Parameters Enter/Exit Programming Mode Flash On Time This feature specifies the ON time for the indicator LED while in Flash Mode. The selectable range is 100 to 9,900 milliseconds (0.1 to 9.9 seconds), in 100 millisecond increments. See "Flash On Time" on page 255 for more detailed pro- gramming instructions.
  • Page 104: Stand Mode Sensitivity

    Enter/Exit Programming Mode Scanning Features Stand Mode Sensitivity Sets the sensitivity level for stand mode wakeup. Choices are low, medium and high. Stand Mode Sensitivity = Low DEFAULT Stand Mode Sensitivity = Medium Stand Mode Sensitivity = High WDI4200...
  • Page 105: Pick Mode

    Reading Parameters Enter/Exit Programming Mode Pick Mode Specifies the ability of the reader to decode labels only when they are close to the center of the aiming pattern. This allows the reader to accurately target labels when they are placed close together, such as on a pick sheet. The Pick Mode can be enabled only in Trigger Single Scan Mode.
  • Page 106: Pick Mode Timeouts

    Aiming pattern appears/desappears before/after the decoding phase (when illuminator is on) starts/ends. The longer the timeout the longer the aiming phase is before and after decoding barcode. Barcode Timeout before Decoding Phase Timeout after Decoding Phase 0.5 s Fast Medium Slow a. Default WDI4200...
  • Page 107: 1D Symbologies

    1D Symbologies Introduction The scanner supports the following 1D symbologies (bar code types). Symbol- ogy-dependent options for each symbology are included in this chapter. See "2D Symbologies" starting on page 201 for configuration of 2D bar codes. on page 115 on page 152 UPC-A 5 (I 2...
  • Page 108: Disable All Symbologies

    3. Complete the programming sequence by scanning the Enter/Exit bar code. $CCPCL00  Coupon Control = Allow all $CCPCL01  DEFAULT Coupon Control = Enable only UPC/EAN $CCPCL02  Coupon Control = Enable only GS1 DataBar WDI4200...
  • Page 109: Upc-A

    1D Symbologies Enter/Exit Programming Mode UPC-A The following options apply to the UPC-A symbology. UPC-A Enable/Disable When disabled, the scanner will not read UPC-A bar codes. $CABEN00  UPC-A = Disable $CABEN01  DEFAULT UPC-A = Enable UPC-A Check Character Transmission Enable this option to transmit the check character along with UPC-A bar code data.
  • Page 110: Expand Upc-A To Ean-13

    UPC-A to EAN-13 = Expand UPC-A Number System Character Transmission This feature enables/disables transmission of the UPC-A number system char- acter. $CABNS00  UPC-A Number System Character = Do not transmit $CABNS01  DEFAULT UPC-A Number System Character = Transmit WDI4200...
  • Page 111: Upc-A 2D Component

    1D Symbologies Enter/Exit Programming Mode UPC-A 2D Component This feature enables/disables a requirement that a 2D label component be decoded when a base label of this symbology is decoded. $CAB2D00(CR) EAN-13 2D Component = Disable (2D component not required) $CAB2D01(CR) EAN-13 2D Component = 2D component must be decoded Product Reference Guide...
  • Page 112: Upc-E

    UPC-E = Enable UPC-E Check Character Transmission Enable this option to transmit the check character along with UPC-E bar code data. $CEBCT00  UPC-E Check Character Transmission = Don’t Send $CEBCT01  DEFAULT UPC-E Check Character Transmission = Send WDI4200...
  • Page 113: Expand Upc-E To Ean-13

    1D Symbologies Enter/Exit Programming Mode Expand UPC-E to EAN-13 Expands UPC-E data to the EAN-13 data format. Selecting this feature also changes the symbology ID to match those required for EAN-13. $CEB3B00  DEFAULT UPC-E to EAN-13 = Don’t Expand ...
  • Page 114: Upc-E Number System Character Transmission

    Enter/Exit Programming Mode UPC-E UPC-E Number System Character Transmission This feature enables/disables transmission of the UPC-E system number char- acter. $CEBNS00  UPC-E Number System Character = Do not transmit  $CEBNS01 DEFAULT UPC-E Number System Character = Transmit WDI4200...
  • Page 115: Ean 13 Enable/Disable

    1D Symbologies Enter/Exit Programming Mode EAN 13 The following options apply to the EAN 13 (Jan 13) symbology. EAN 13 Enable/Disable When disabled, the scanner will not read EAN 13/JAN 13 bar codes. $C3BEN00  EAN 13 = Disable  $C3BEN01 DEFAULT EAN 13 = Enable...
  • Page 116: Ean-13 Flag 1 Character

    EAN-13 Flag 1 Char= Transmit EAN-13 ISBN Conversion This option enables/disables conversion of EAN 13/JAN 13 Bookland labels starting with 978 to ISBN labels. $C3BIS00  DEFAULT EAN-13 ISBN Conversion = Disable $C3BIS01  EAN-13 ISBN Conversion = Convert to ISBN WDI4200...
  • Page 117: Issn Enable/Disable

    1D Symbologies Enter/Exit Programming Mode EAN-13 2D Component This feature enables/disables a requirement that a 2D label component be decoded when a base label of this symbology is decoded. $C3B2D00(CR) DEFAULT EAN-13 2D Component = Disable (2D component not required) EAN-13 2D Component = 2D component must be decoded ISSN Enable/Disable...
  • Page 118: Ean 8

    EAN 8 Check Character Transmission Enable this option to transmit the check character along with EAN 8 bar code data.  $C8BCT00 EAN 8 Check Character Transmission = Don’t Send $C8BCT01  DEFAULT EAN 8 Check Character Transmission = Send WDI4200...
  • Page 119: Expand Ean 8 To Ean 13

    1D Symbologies Enter/Exit Programming Mode Expand EAN 8 to EAN 13 Enable this option to expand EAN 8/JAN 8 labels to EAN 13/JAN 13. $C8B3B00  DEFAULT Expand EAN 8 to EAN 13 = Disable $C8B3B01  Expand EAN 8 to EAN 13 = Enable EAN 8 2D Component This feature enables/disables a requirement that a 2D label component be decoded when a base label for this symbology is decoded.
  • Page 120: Upc/Ean Global Settings

    Enable European 5-digit price-weight check-digit calculation DEFAULT $Price Weight Check = Disabled $Price Weight Check = 4-digit price-weight check $Price Weight Check = 5-digit price-weight check $Price Weight Check = European 4-digit price-weight check $Price Weight Check = European 5-digit price-weight check WDI4200...
  • Page 121: Add-Ons

    1D Symbologies Enter/Exit Programming Mode Add-Ons The following features apply to optional add-ons. Contact Customer Support for advanced programming of optional and conditional add-ons. NOTE Optional Add-ons The scanner can be enabled to optionally read the following add-ons (supple- mentals): •...
  • Page 122: Optional Add-On Timer

    Optional Add-on Timer = 20ms $CADOT03  Optional Add-on Timer = 30ms $CADOT05  Optional Add-on Timer = 50ms $CADOT07  DEFAULT Optional Add-on Timer = 70ms $CADOT0A  Optional Add-on Timer = 100ms $CADOT10  Optional Add-on Timer = 160ms WDI4200...
  • Page 123: Gs1 Databar Omnidirectional

    1D Symbologies Enter/Exit Programming Mode ™ GS1 DataBar Omnidirectional The following options apply to the GS1 DataBar Omnidirectional (formerly RSS- 14) symbology. GS1 DataBar Omnidirectional Enable/Disable When disabled, the scanner will not read GS1 DataBar Omnidirectional bar codes. $C4BEN00  DEFAULT GS1 DataBar Omnidirectional = Disable $C4BEN01...
  • Page 124: Gs1 Databarâ„¢ Omnidirectional 2D Component

    This feature enables/disables a requirement that a 2D label component be decoded when a base label for this symbology is decoded. DEFAULT GS1 DataBar™ Omnidirectional 2D Component = Disable (2D component not required) GS1 DataBar™ Omnidirectional 2D Component = 2D component must be decoded WDI4200...
  • Page 125: Gs1 Databarâ„¢ Expanded

    1D Symbologies Enter/Exit Programming Mode GS1 DataBar™ Expanded The following options apply to the GS1 DataBar Expanded (formerly RSS Expanded) symbology. GS1 DataBar Expanded Enable/Disable When disabled, the scanner will not read GS1 DataBar Expanded bar codes. $CXBEN00  DEFAULT GS1 DataBar Expanded = Disable $CXBEN01 ...
  • Page 126: Gs1 Databar Expanded Length Control

    Select GS1 DataBar Expanded Set Length 1 Setting Make a mistake? Scan the CANCEL bar code to abort and not save the entry string. You can then start again at the beginning. CANCEL 01 = Length 1 is 1 Character DEFAULT WDI4200...
  • Page 127: Gs1 Databar Expanded Set Length 2

    1D Symbologies Enter/Exit Programming Mode GS1 DataBar Expanded Set Length 2 This feature specifies one of the bar code lengths for GS1 DataBar Expanded Length Control on page 132. Length 2 is the maximum label length if in Vari- able Length on page 132 Mode, or the second fixed length if in Fixed Length on page 132...
  • Page 128: Gs1 Databarâ„¢ Limited

    GS1 DataBar Limited GS1-128 Emulation When enabled, GS1 DataBar Limited bar codes will be translated to the GS1-128 label data format. $CLBU800  DEFAULT GS1 DataBar Limited GS1-128 Emulation = Disable $CLBU801  GS1 DataBar Limited GS1-128 Emulation = Enable WDI4200...
  • Page 129: Code 39

    1D Symbologies Enter/Exit Programming Mode Code 39 The following options apply to the Code 39 symbology. Code 39 Enable/Disable When disabled, the scanner will not read Code 39 bar codes. $CC3EN00  Code 39 = Disable $CC3EN01  DEFAULT Code 39 = Enable Product Reference Guide...
  • Page 130: Code 39 Check Character Calculation

    Code 39 Check Character Calculation = Calculate Std Check $CC3CC02  Code 39 Check Character Calculation = Calculate Mod 7 Check $CC3CC04  Code 39 Check Character Calculation = Enable Italian Post Check $CC3CC08  Code 39 Check Character Calculation = Enable Daimler Chrysler Check WDI4200...
  • Page 131: Code 39 Check Character Transmission

    1D Symbologies Enter/Exit Programming Mode Code 39 Check Character Transmission Enable this option to transmit the check character along with Code 39 bar code data. $CC3CT00  Code 39 Check Character Transmission = Don’t Send $CC3CT01  DEFAULT Code 39 Check Character Transmission = Send Code 39 Start/Stop Character Transmission Enable this option to enable/disable transmission of Code 39 start and stop characters.
  • Page 132: Code 39 Full Ascii

    Code 39 Full ASCII In Code 39 decoding, this enables/disables the translation of Code 39 charac- ters to Code 39 full-ASCII characters. $CC3FA00  DEFAULT Code 39 Full ASCII = Disable $CC3FA01  Code 39 Full ASCII = Enable WDI4200...
  • Page 133: Code 39 Quiet Zones

    1D Symbologies Enter/Exit Programming Mode Code 39 Quiet Zones This feature specifies the number of quiet zones for Code 39 labels. Quiet zones are blank areas at the ends of a bar code and are typically 10 times the width of the narrowest bar or space in the label. $CC3LO01 ...
  • Page 134: Code 39 Length Control

    For variable length decoding, a minimum and maximum length Variable Length: may be set. For fixed length decoding, two different lengths may be set. Fixed Length:  $CC3LC00 DEFAULT Code 39 Length Control = Variable Length $CC3LC01  Code 39 Length Control = Fixed Length WDI4200...
  • Page 135: Code 39 Set Length 1

    1D Symbologies Enter/Exit Programming Mode Code 39 Set Length 1 This feature specifies one of the bar code lengths for Code 39 Length Control on page 140. Length 1 is the minimum label length if in Variable Length on page 140 Mode, or the first fixed length if in Fixed Length on page 140 Mode.
  • Page 136: Code 39 Set Length 2

    Select Code 39 Length 2 Setting Make a mistake? Scan the CANCEL bar code to abort and not save the entry string. You can then start again at the beginning. CANCEL 50 = Length 2 is 50 Characters DEFAULT WDI4200...
  • Page 137: Code 32 (Italian Pharmaceutical)

    1D Symbologies Enter/Exit Programming Mode Code 32 (Italian Pharmaceutical) The following options apply to the Code 32 symbology. Code 32 Enable/Disable When disabled, the scanner will not read Code 32 bar codes. $CP3EN00  DEFAULT Code 32 = Disable $CP3EN01 ...
  • Page 138: Code 32 Start/Stop Character Transmission

    The following options apply to the Code 39 CIP symbology. Code 39 CIP Enable/Disable Enables/Disables ability of the scanner to decode Code 39 CIP labels. $CCCEN00  DEFAULT Code 39 CIP = Disable $CCCEN01  Code 39 CIP = Enable WDI4200...
  • Page 139: Code 128

    1D Symbologies Enter/Exit Programming Mode Code 128 The following options apply to the Code 128 symbology. Code 128 Enable/Disable When disabled, the scanner will not read Code 128 bar codes. $CC8EN00  Code 128 = Disable $CC8EN01  DEFAULT Code 128 = Enable Expand Code 128 to Code 39 This feature enables/disables expansion of Code 128 labels to Code 39 labels.
  • Page 140: Code 128 Check Character Transmission

    Code 128 Check Character Transmission = Send Code 128 Function Character Transmission Enables/disables transmission of Code128 function characters 1, 2, 3, and 4. $CC8TF00  DEFAULT Code 128 Function Character Transmission = Don’t Send $CC8TF01  Code 128 Function Character Transmission = Send WDI4200...
  • Page 141: Code 128 Quiet Zones

    1D Symbologies Enter/Exit Programming Mode Code 128 Quiet Zones This feature specifies the number of quiet zones for Code 128 labels. Quiet zones are blank areas at the ends of a bar code and are typically 10 times the width of the narrowest bar or space in the label. $CC8LO00 ...
  • Page 142: Code 128 Length Control

    For variable length decoding, a minimum and maximum length Variable Length: may be set. For fixed length decoding, two different lengths may be set. Fixed Length:  $CC8LC00 DEFAULT Code 128 Length Control = Variable Length $CC8LC01  Code 128 Length Control = Fixed Length WDI4200...
  • Page 143: Code 128 Set Length 1

    1D Symbologies Enter/Exit Programming Mode Code 128 Set Length 1 This feature specifies one of the bar code lengths for Code 128 Length Control on page 148. Length 1 is the minimum label length if in Variable Length on page 148 Mode, or the first fixed length if in Fixed Length on page 148 Mode.
  • Page 144: Code 128 Set Length 2

    Select Code 128 Length 2 Setting Make a mistake? Scan the CANCEL bar code to abort and not save the entry string. You can then start again at the beginning. CANCEL 80 = Length 2 is 80 Characters DEFAULT WDI4200...
  • Page 145: Gs1-128

    1D Symbologies Enter/Exit Programming Mode GS1-128 The following options apply to the GS1-128 symbology. (Also known as USS- 128, GTIN-128, UCC-128.) GS1-128 Enable This option enables/disables the ability of the scanner to translate GS1-128 labels to the GS1-128 data format. Options are: •...
  • Page 146: Interleaved 2 Of 5 (I 2 Of 5)

    CAUTION I 2 of 5 Enable/Disable When disabled, the scanner will not read I 2 of 5 bar codes. $CI2EN00  DEFAULT I 2 of 5 = Disable  $CI2EN01 I 2 of 5 = Enable WDI4200...
  • Page 147: I 2 Of 5 Check Character Calculation

    1D Symbologies Enter/Exit Programming Mode I 2 of 5 Check Character Calculation This option enables/disables calculation and verification of an optional I 2 of 5 check character. $CI2CC00  DEFAULT I 2 of 5 Check Char Calc = Disable  $CI2CC01 I 2 of 5 Check Char Calc = Check Standard (Modulo 10)
  • Page 148: I 2 Of 5 Check Character Transmission

    Variable Length: may be set. For fixed length decoding, two different lengths may be set. Fixed Length: $CI2LC00  DEFAULT I 2 of 5 Length Control = Variable Length $CI2LC01  I 2 of 5 Length Control = Fixed Length WDI4200...
  • Page 149 1D Symbologies Enter/Exit Programming Mode I 2 of 5 Set Length 1 This feature specifies one of the bar code lengths for I 2 of 5 Length Control on page 154. Length 1 is the minimum label length if in Variable Length on page Mode, or the first fixed length if in Fixed Length on page 159...
  • Page 150 Select I 2 of 5 Length 2 Setting Make a mistake? Scan the CANCEL bar code to abort and not save the entry string. You can then start again at the beginning. CANCEL 50 = Length 2 is 50 Characters DEFAULT WDI4200...
  • Page 151: Interleaved 2 Of 5 Cip Hr

    1D Symbologies Enter/Exit Programming Mode Interleaved 2 of 5 CIP HR The following options apply to the Interleaved 2 of 5 CIP HR symbology. Interleaved 2 of 5 CIP HR Enable/Disable Enables/Disables ability of scanner to decode Interleaved 2 of 5 CIP HR labels. $CCHEN00 ...
  • Page 152: Datalogic 2 Of 5

    This option enables/disables calculation and verification of an optional Data- logic 2 of 5 check character. $CD2CC00  DEFAULT Datalogic 2 of 5 Check Character Calculation = Disable $CD2CC01  Datalogic 2 of 5 Check Character Calculation = Enable WDI4200...
  • Page 153: Datalogic 2 Of 5 Check Character Transmission

    1D Symbologies Enter/Exit Programming Mode Datalogic 2 of 5 Check Character Transmission This option enables/disables transmission of an optional Datalogic 2 of 5 char- acter. $CD2CT00  Datalogic 2 of 5 Check Character Transmission = Don’t Send $CD2CT01  DEFAULT Datalogic 2 of 5 Check Character Transmission = Send Datalogic 2 of 5 Length Control This feature specifies either variable length decoding or fixed length decoding...
  • Page 154: Datalogic 2 Of 5 Set Length 1

    Select Datalogic 2 of 5 Length 1 Setting Make a mistake? Scan the CANCEL bar code to abort and not save the entry string. You can then start again at the beginning. CANCEL 06 = Length 1 is 6 Characters DEFAULT WDI4200...
  • Page 155: Datalogic 2 Of 5 Set Length 2

    1D Symbologies Enter/Exit Programming Mode Datalogic 2 of 5 Set Length 2 This feature specifies one of the bar code lengths for Datalogic 2 of 5 Length Control on page 159. Length 2 is the maximum label length if in Variable Length on page 154 Mode, or the second fixed length if in...
  • Page 156: Codabar

    $CCBCC00  DEFAULT Codabar Check Character Calculation = Don’t Calculate $CCBCC01  Codabar Check Character Calculation = Enable AIM standard check char. $CCBCC02  Codabar Check Character Calculation = Enable Modulo 10 check char. WDI4200...
  • Page 157: Codabar Check Character Transmission

    1D Symbologies Enter/Exit Programming Mode Codabar Check Character Transmission Enable this option to transmit the check character along with Codabar bar code data. This feature is valid only when Codabar Check Character Calculation is enabled. NOTE $CCBCT00  Codabar Check Character Transmission = Don’t Send $CCBCT01 ...
  • Page 158: Codabar Start/Stop Character Set

    Codabar Check Character Set = abcd/abcd Codabar Start/Stop Character Match When enabled, this option requires that start and stop characters match. $CCBSM00  DEFAULT Codabar Start/Stop Character Match = Don’t Require Match $CCBSM01  Codabar Start/Stop Character Match = Require Match WDI4200...
  • Page 159: Codabar Quiet Zones

    1D Symbologies Enter/Exit Programming Mode Codabar Quiet Zones This feature specifies the number of quiet zones for Codabar labels. Quiet zones are blank areas at the ends of a bar code and are typically 10 times the width of the narrowest bar or space in the label. $CCBLO01 ...
  • Page 160: Codabar Length Control

    For variable length decoding, a minimum and maximum length Variable Length: may be set. For fixed length decoding, two different lengths may be set. Fixed Length:  $CCBLC00 DEFAULT Codabar Length Control = Variable Length $CCBLC01  Codabar Length Control = Fixed Length WDI4200...
  • Page 161: Codabar Set Length 1

    1D Symbologies Enter/Exit Programming Mode Codabar Set Length 1 This feature specifies one of the bar code lengths for Codabar Length Control on page 166. Length 1 is the minimum label length if in Variable Length on page 166 Mode, or the first fixed length if in Fixed Length on page 166 Mode.
  • Page 162: Codabar Set Length 2

    ENTER/EXIT bar code again. Select Codabar Length 2 Setting Make a mistake? Scan the CANCEL bar code to abort and not save the entry string. You can then start again at the beginning. CANCEL 50 = Length 2 is 50 Characters DEFAULT WDI4200...
  • Page 163: Abc Codabar

    1D Symbologies Enter/Exit Programming Mode ABC Codabar The following options apply to the ABC Codabar symbology. ABC Codabar Enable/Disable Enables/Disables ability of scanner to decode ABC Codabar labels. $CCBAB00  DEFAULT ABC Codabar = Disable $CCBAB01  ABC Codabar = Enable ABC Codabar Concatenation Mode Specifies the concatenation mode between Static and Dynamic.
  • Page 164: Abc Codabar Dynamic Concatenation Timeout

    Force Concatenation has no effect if the ABC Codabar Concatenation is dis- abled. The Force Concatenation mode has effect both in Static and Dynamic Concatenation Modes. $CCBFC00  DEFAULT ABC Codabar Force Concatenation = Disable $CCBFC01  ABC Codabar Force Concatenation = Enable WDI4200...
  • Page 165: Code 11

    1D Symbologies Enter/Exit Programming Mode Code 11 The following options apply to the Code 11 symbology. Code 11 Enable/Disable When disabled, the scanner will not read Code 11 bar codes. $CC1EN00  DEFAULT Code 11 = Disable  $CC1EN01 Code 11 = Enable Product Reference Guide...
  • Page 166: Code 11 Check Character Calculation

    Code 11 Check Character Calculation = Check C and K Code 11 Check Character Transmission This feature enables/disables transmission of an optional Code 11 check char- acter. $CC1CT00  Code 11 Check Character Transmission = Don’t Send $CC1CT01  DEFAULT Code 11 Check Character Transmission = Send WDI4200...
  • Page 167: Code 11 Length Control

    1D Symbologies Enter/Exit Programming Mode Code 11 Length Control This feature specifies either variable length decoding or fixed length decoding for the Code 11 symbology. For variable length decoding, a minimum and maximum length Variable Length: may be set. For fixed length decoding, two different lengths may be set. Fixed Length: $CC1LC00 ...
  • Page 168: Code 11 Set Length 2

    Select Code 11 Length 2 Setting Make a mistake? Scan the CANCEL bar code to abort and not save the entry string. You can then start again at the beginning. CANCEL 50 = Length 2 is 50 Characters DEFAULT WDI4200...
  • Page 169: Standard 2 Of 5

    1D Symbologies Enter/Exit Programming Mode Standard 2 of 5 The following options apply to the Standard 2 of 5 symbology. Standard 2 of 5 Enable/Disable When disabled, the scanner will not read Standard 2 of 5 bar codes. $CS2EN00  DEFAULT Standard 2 of 5 = Disable $CS2EN01...
  • Page 170: Standard 2 Of 5 Check Character Transmission

    Variable Length: may be set. For fixed length decoding, two different lengths may be set. Fixed Length: $CS2LC00  DEFAULT Standard 2 of 5 Length Control = Variable Length $CS2LC01  Standard 2 of 5 Length Control = Fixed Length WDI4200...
  • Page 171: Standard 2 Of 5 Set Length 1

    1D Symbologies Enter/Exit Programming Mode Standard 2 of 5 Set Length 1 This feature specifies one of the bar code lengths for Standard 2 of 5 Length Control on page 176. Length 1 is the minimum label length if in Variable Length on page 176 Mode, or the first fixed length if in...
  • Page 172: Standard 2 Of 5 Set Length 2

    Select Standard 2 of 5 Length 2 Setting Make a mistake? Scan the CANCEL bar code to abort and not save the entry string. You can then start again at the beginning. CANCEL 50 = Length 2 is 50 Characters DEFAULT WDI4200...
  • Page 173: Industrial 2 Of 5

    1D Symbologies Enter/Exit Programming Mode Industrial 2 of 5 The following options apply to the Industrial 2 of 5 symbology. Industrial 2 of 5 Enable/Disable Enables/Disables ability of scanner to decode Industrial 2 of 5 labels. $CU2EN00  DEFAULT Industrial 2 of 5 = Disable $CU2EN01 ...
  • Page 174: Industrial 2 Of 5 Check Character Transmission

    For variable length decoding, a minimum and maximum length Variable Length: may be set. For fixed length decoding, two different lengths may be set. Fixed Length: $CU2LC00  DEFAULT Industrial 2 of 5 Length Control = Variable Length  $CU2LC01 Industrial 2 of 5 = Fixed Length WDI4200...
  • Page 175: Industrial 2 Of 5 Set Length 1

    1D Symbologies Enter/Exit Programming Mode Industrial 2 of 5 Set Length 1 This feature specifies one of the bar code lengths for Industrial 2 of 5 Length Control on page 180. Length 1 is the minimum label length if in Variable Length on page 140 Mode, or the first fixed length if in...
  • Page 176: Industrial 2 Of 5 Set Length 2

    Select Industrial 2 of 5 Length 2 Setting Make a mistake? Scan the CANCEL bar code to abort and not save the entry string. You can then start again at the beginning. CANCEL 50 = Length 2 is 50 Characters DEFAULT WDI4200...
  • Page 177: Iata

    1D Symbologies Enter/Exit Programming Mode IATA The following options apply to the IATA symbology. IATA Enable/Disable Enables/Disables the ability of the scanner to decode IATA labels. $CIAEN00  DEFAULT IATA = Disable $CIAEN01  IATA = Enable IATA Check Character Transmission Enables/Disables calculation and verification of an optional Industrial 2 of 5 check character.
  • Page 178: Isbt 128

    Specifies the concatenation mode between Static and Dynamic. This option is only valid when ISBT 128 Concatenation on page 184 is enabled (see page 10-184). NOTE $CI8CM00  DEFAULT ISBT 128 Concatenation Mode = Static $CI8CM01  ISBT 128 Concatenation Mode = Dynamic WDI4200...
  • Page 179: Isbt 128 Dynamic Concatenation Timeout

    1D Symbologies Enter/Exit Programming Mode ISBT 128 Dynamic Concatenation Timeout Specifies the timeout used by the ISBT 128 Dynamic Concatenation Mode. $CI8DT05  ISBT 128 Dynamic Concatenation Timeout = 50 msec $CI8DT0A  ISBT 128 Dynamic Concatenation Timeout = 100 msec $CI8DT14 ...
  • Page 180: Isbt 128 Force Concatenation

    184 is enabled. (see page 10-184). NOTE $CI8FC00  DEFAULT ISBT 128 Force Concatenation = Disable $CI8FC01  ISBT 128 Force Concatenation = Enable ISBT 128 Advanced Concatenation Options Contact Customer Support to set up pairs of label types for concatenation. NOTE WDI4200...
  • Page 181: Msi

    1D Symbologies Enter/Exit Programming Mode The following options apply to the MSI symbology. MSI Enable/Disable Enables/Disables ability of scanner to decode MSI labels. $CMSEN00  DEFAULT MSI = Disable  $CMSEN01 MSI = Enable MSI Check Character Calculation Enables/Disables calculation and verification of an optional MSI check charac- ter.
  • Page 182: Msi Check Character Transmission

    For variable length decoding, a minimum and maximum length Variable Length: may be set. For fixed length decoding, two different lengths may be set. Fixed Length: $CMSLC00  DEFAULT MSI Length Control = Variable Length $CMSLC01  MSI = Fixed Length WDI4200...
  • Page 183 1D Symbologies Enter/Exit Programming Mode MSI Set Length 1 This feature specifies one of the bar code lengths for MSI Length Control on page 188. Length 1 is the minimum label length if in Variable Length on page Mode, or the first fixed length if in Fixed Length on page 188 Mode.
  • Page 184 ENTER/EXIT bar code again. Select MSI Length 2 Setting Make a mistake? Scan the CANCEL bar code to abort and not save the entry string. You can then start again at the beginning. CANCEL 50 = Length 2 is 50 Characters DEFAULT WDI4200...
  • Page 185: Code 93 Enable/Disable

    1D Symbologies Enter/Exit Programming Mode Code 93 The following options apply to the Code 93 symbology. Code 93 Enable/Disable Enables/Disables ability of scanner to decode Code 93 labels. $CC9EN00  DEFAULT Code 93 = Disable $CC9EN01  Code 93 = Enable Product Reference Guide...
  • Page 186: Code 93 Check Character Calculation

    Code 93 Check Character Calculation = Enable Check C and K Code 93 Check Character Transmission Enables/disables transmission of an optional Code 93 check character. $CC9CT00  Code 93 Check Character Transmission = Disable $CC9CT01  DEFAULT Code 93 Check Character Transmission = Enable WDI4200...
  • Page 187: Code 93 Length Control

    1D Symbologies Enter/Exit Programming Mode Code 93 Length Control This feature specifies either variable length decoding or fixed length decoding for the Code 93 symbology. For variable length decoding, a minimum and maximum length Variable Length: may be set. For fixed length decoding, two different lengths may be set. Fixed Length: ...
  • Page 188: Code 93 Set Length 1

    Select Code 93 Set Length 1 Setting Make a mistake? Scan the CANCEL bar code to abort and not save the entry string. You can then start again at the beginning. CANCEL 01 = Length 1 is 1 Character DEFAULT WDI4200...
  • Page 189: Code 93 Set Length 2

    1D Symbologies Enter/Exit Programming Mode Code 93 Set Length 2 This feature specifies one of the bar code lengths for Code 93 Length Control on page 193. Length 2 is the maximum label length if in Variable Length on page 193 Mode, or the second fixed length if in Fixed Length on page 193 Mode.
  • Page 190: Code 93 Quiet Zones

    Code 93 Quiet Zones = Quiet Zone on one side  $CC9LO02 Code 93 Quiet Zones = Quiet Zones on two sides $CC9LO03  DEFAULT Code 93 Quiet Zones = Auto $CC9LO04  Code 93 Quiet Zones = Virtual Quiet Zones on two sides WDI4200...
  • Page 191: Follett 2 Of 5

    1D Symbologies Enter/Exit Programming Mode Follett 2 of 5 The following options apply to the Follett 2 of 5 symbology. Follett 2 of 5 Enable/Disable Enables/Disables ability of scanner to decode Follett 2 of 5 labels. $CF2EN00  DEFAULT Follett 2 of 5 = Disable ...
  • Page 192: Bc412 Check Character Calculation

    For variable length decoding, a minimum and maximum length Variable Length: may be set. For fixed length decoding, two different lengths may be set. Fixed Length: $CBCLC00  DEFAULT BC412 Length Control = Variable Length  $CBCLC01 BC412 Length Control = Fixed Length WDI4200...
  • Page 193: Bc412 Set Length 1

    1D Symbologies Enter/Exit Programming Mode BC412 Set Length 1 This feature specifies one of the bar code lengths for BC412 Length Control on page 198. Length 1 is the minimum label length if in Variable Length on page Mode, or the first fixed length if in Fixed Length on page 198 Mode.
  • Page 194: Bc412 Set Length 2

    ENTER/EXIT bar code again. Select BC412 Length 2 Setting Make a mistake? Scan the CANCEL bar code to abort and not save the entry string. You can then start again at the beginning. CANCEL 50 = Length 2 is 50 Characters DEFAULT WDI4200...
  • Page 195: "1D Symbologies

    2D Symbologies on page 202 2D G LOBAL EATURES 2D N ORMAL NVERSE YMBOL ONTROL on page 203 2D M AXIMUM ECODING page 204 on page 204 2D S TRUCTURED PPEND The reader supports the following 2D symbologies (bar code types). Symbol- ogy-dependent options for each symbology are included in this chapter.
  • Page 196 If you make a mistake before the last character, scan the CANCEL bar code to abort and not save the entry string. You can then start again at the beginning. NOTE Complete the programming sequence by scanning the ENTER/EXIT PROGRAM- MING bar code to exit Programming Mode. WDI4200...
  • Page 197 2D Symbologies Enter/Exit Programming Mode 2D Maximum Decoding Time This feature specifies the maximum amount of time the software will spend attempting to decode a 2D label. The selectable range is 10 milliseconds to 2.55 milliseconds. 2D Maximum Decoding Time = 100 msec 2D Maximum Decoding Time = 200 msec DEFAULT 2D Maximum Decoding Time = 350 msec...
  • Page 198: Structured Append

    This configuration item applies globally to all the 2D symbologies that support that feature according to Standard AIM Specification: Data Matrix, QR, MicroQR, Aztec and Chinese Sensible Code. DEFAULT Normal/Inverse Symbol Control = Normal Normal/Inverse Symbol Control = Inverse Normal/Inverse Symbol Control = Both Normal and Inverse WDI4200...
  • Page 199: Symbology Selection

    Symbology Selection Enter/Exit Programming Mode Symbology Selection Aztec Code Aztec Code Enable / Disable Enables/disables the ability of the reader to decode Aztec Code labels. $CAZEN00(CR) DEFAULT Aztec Code = Disable $CAZEN01(CR) Aztec Code = Enable Aztec Code Length Control This feature specifies either variable length decoding or fixed length decoding for this symbology.
  • Page 200 Select Aztec Code Length 1 Setting bar code again. Make a mistake? Scan the CANCEL bar code to abort and not save the entry string. You can then start again at the beginning. CANCEL 0001 = Length 1 is 1 Character DEFAULT WDI4200...
  • Page 201 Symbology Selection Enter/Exit Programming Mode Aztec Code Set Length 2 This feature specifies one of the bar code lengths for Aztec Code Length Con- trol on page 205. Length 2 is the maximum label length if in Variable Length Mode, or the second fixed length if in Fixed Length Mode. Characters can be set from 0001 to 3,832 characters in increments of 0001 (pad with zeroes).
  • Page 202: China Sensible Code

    For variable length decoding, a minimum and maximum length Variable Length: may be set. For fixed length decoding, two different lengths may be set. Fixed Length: DEFAULT China Sensible Code Length Control = Variable Length China Sensible Code Length Control = Fixed Length WDI4200...
  • Page 203 Symbology Selection Enter/Exit Programming Mode China Sensible Code Set Length 1 Specifies one of the bar code lengths for China Sensible Code Length Control on page 208. Length 1 is the minimum label length if in Variable Length Mode, or the first fixed length if in Fixed Length Mode. Characters can be set from 0001 to 7,827 characters in increments of 0001 (pad with zeroes).
  • Page 204 End by scanning the ENTER/EXIT bar code again. Make a mistake? Scan the CANCEL bar code to abort and not save the entry string. You can then start again at the beginning. CANCEL Length 2 is 7,827 Characters DEFAULT WDI4200...
  • Page 205: Data Matrix

    Symbology Selection Enter/Exit Programming Mode Data Matrix Data Matrix Enable / Disable Enables/disables ability of reader to decode Data Matrix labels. Data Matrix = Disable DEFAULT Data Matrix = Enable Data Matrix Square/Rectangular Style Specifies the options available when reading Data Matrix with different form factors.
  • Page 206: Data Matrix Length Control

    Select Data Matrix Length 1 Setting bar code again. Make a mistake? Scan the CANCEL bar code to abort and not save the entry string. You can then start again at the beginning. CANCEL 0001 = Length 1 is 1 Character DEFAULT WDI4200...
  • Page 207 Symbology Selection Enter/Exit Programming Mode Data Matrix Set Length 2 This feature specifies one of the bar code lengths for Data Matrix Length Con- trol on page 212. Length 2 is the maximum label length if in Variable Length Mode, or the second fixed length if in Fixed Length Mode. Characters can be set from 0001 to 3,116 characters in increments of 0001 (pad with zeroes).
  • Page 208: Maxicode

    DEFAULT Maxicode = Disable Maxicode = Enable Maxicode Primary Message Transmission Enables/disables the transmission of only the Primary Message when the Secondary Message is not readable. DEFAULT Maxicode Primary Message Transmission = Disable Maxicode Primary Message Transmission = Enable WDI4200...
  • Page 209: Maxicode Length Control

    Symbology Selection Enter/Exit Programming Mode Maxicode Length Control This feature specifies either variable length decoding or fixed length decoding for this symbology. For variable length decoding, a minimum and maximum length Variable Length: may be set. For fixed length decoding, two different lengths may be set. Fixed Length: DEFAULT Maxicode Length Control = Variable Length...
  • Page 210 Select Maxicode Length 2 Setting bar code again. Make a mistake? Scan the CANCEL bar code to abort and not save the entry string. You can then start again at the beginning. CANCEL Length 2 is 0145 Characters DEFAULT WDI4200...
  • Page 211: Pdf417

    Symbology Selection Enter/Exit Programming Mode PDF417 PDF417 Enable / Disable Enables/disables the ability of the reader to decode PDF417 labels. PDF417 = Disable DEFAULT PDF417 = Enable PDF417 Length Control This feature specifies either variable length decoding or fixed length decoding for this symbology.
  • Page 212 Select PDF417 Length 1 Setting bar code again. Make a mistake? Scan the CANCEL bar code to abort and not save the entry string. You can then start again at the beginning. CANCEL 0001 = Length 1 is 1 Character DEFAULT WDI4200...
  • Page 213 Symbology Selection Enter/Exit Programming Mode PDF417 Set Length 2 This feature specifies one of the bar code lengths for PDF417 Length Control on page 217. Length 2 is the maximum label length if in Variable Length Mode, or the second fixed length if in Fixed Length Mode. Length includes the bar code’s check, data, and full-ASCII shift characters.
  • Page 214: Micro Pdf417

    Code 128 / EAN128 AIM Id and label type DEFAULT Micro PDF417 Code 128 GS1-128 Emulation = Micro PDF AIM ID and label type Micro PDF417 Code 128 GS1-128 Emulation = Code 128 / EAN128 AIM ID and label type WDI4200...
  • Page 215: Micro Pdf417 Length Control

    Symbology Selection Enter/Exit Programming Mode Micro PDF417 Length Control This feature specifies either variable length decoding or fixed length decoding for this symbology. For variable length decoding, a minimum and maximum length Variable Length: may be set. For fixed length decoding, two different lengths may be set. Fixed Length: DEFAULT Micro PDF417 Length Control = Variable Length...
  • Page 216 Select Micro PDF417 Length 2 Setting bar code again. Make a mistake? Scan the CANCEL bar code to abort and not save the entry string. You can then start again at the beginning. CANCEL Length 2 is 0366 Characters DEFAULT WDI4200...
  • Page 217: Qr Code

    Symbology Selection Enter/Exit Programming Mode QR Code QR Code Enable / Disable Enables/disables the ability of the reader to decode QR Code labels. QR Code = Disable DEFAULT QR Code = Enable QR Code Length Control This feature specifies either variable length decoding or fixed length decoding for this symbology.
  • Page 218 Select QR Code Length 1 Setting bar code again. Make a mistake? Scan the CANCEL bar code to abort and not save the entry string. You can then start again at the beginning. CANCEL 0001 = Length 1 is 1 Character DEFAULT WDI4200...
  • Page 219 Symbology Selection Enter/Exit Programming Mode QR Code Set Length 2 This feature specifies one of the bar code lengths for QR Code Length Control on page 223. Length 2 is the maximum label length if in Variable Length Mode, or the second fixed length if in Fixed Length Mode. Characters can be set from 0001 to 7,089 characters in increments of 0001 (pad with zeroes).
  • Page 220: Micro Qr Code

    For variable length decoding, a minimum and maximum length Variable Length: may be set. For fixed length decoding, two different lengths may be set. Fixed Length: DEFAULT Micro QR Code Length Control = Variable Length Micro QR Code Length Control = Fixed Length WDI4200...
  • Page 221 Symbology Selection Enter/Exit Programming Mode Micro QR Code Set Length 1 Specifies one of the bar code lengths for Micro QR Code Length Control on page 226. Length 1 is the minimum label length if in Variable Length Mode, or the first fixed length if in Fixed Length Mode.
  • Page 222 Select QR Code Length 2 Setting bar code again. Make a mistake? Scan the CANCEL bar code to abort and not save the entry string. You can then start again at the beginning. CANCEL Length 2 is 0035 Characters DEFAULT WDI4200...
  • Page 223: Ucc Composite

    Symbology Selection Enter/Exit Programming Mode UCC Composite UCC Optional Composite Timer Specifies the amount of time the system will wait for the stacked part of a UCC Composite label before transmitting the linear label without an add-on. DEFAULT UCC Optional Composite Timer = Timer Disabled UCC Optional Composite Timer = 100msec UCC Optional Composite Timer = 200msec UCC Optional Composite Timer = 300msec...
  • Page 224: Postal Code Selection

    Postal Code Selection = Disable All Postal Codes Postal Code Selection = Enable Postnet Postal Code Selection = Enable Planet Postal Code Selection = Enable Royal Mail Postal Code Selection = Enable Kix Postal Code Selection = Enable Australia Post WDI4200...
  • Page 225: Postnet Bb Control

    Postal Code Selection Postal Code Selection (continued) Postal Code Selection = Enable Japan Post Postal Code Selection = Enable IMB Postal Code Selection = Enable Sweden Post Postal Code Selection = Enable Portugal Post Postnet BB Control Controls the ability of the scanner to decode B and B' fields of Postnet labels. DEFAULT Postnet BB Control = Disable Postnet BB Control = Enable...
  • Page 226 Symbology Selection WDI4200...
  • Page 227 Chapter 4 References This section contains explanations and examples of selected bar code features. "Configuration Using Bar Codes" starting on page 17 for the actual bar code labels used to configure the scanner. on page 234 RS-232 P ARAMETERS on page RS-232/USB COM P ARAMETERS on page 234...
  • Page 228: References

    RTS/XON/XOFF — RTS is asserted during transmissions. CTS is ignored. XON and XOFF gate transmissions. • RTS On/CTS — RTS is always asserted. CTS gates transmissions. • RTS/CTS Scan Control — RTS is asserted during transmissions. CTS gates transmissions and controls enable and disable state of scanner. WDI4200...
  • Page 229: Rs-232/Usb Com Parameters

    RS-232 Parameters RS-232/USB COM Parameters Intercharacter Delay This parameter specifies the intercharacter delay between the end of one char- acter and the beginning of the next. The delay can be set within a range of zero (0) to 990 milliseconds in 10ms increments. A setting of zero specifies no delay.
  • Page 230 0x24 0x40 0x3E Chart on page 297 Scan ENTER/EXIT PROGRAMMING MODE Scan SELECT ACK CHARACTER SETTING Scan Two Characters from ‘0’ and ‘6’ ‘2’ and ‘4’ ‘4’ and ‘0’ ‘3’ AND ‘E’ Appendix D, Keypad Scan ENTER/EXIT PROGRAMMING MODE WDI4200...
  • Page 231 RS-232 Parameters NAK Character This setting specifies an ASCII character or hex value to be used as the NAK character. ASCII characters or any hex value from 0 to 0xFF can be selected. Setting to previously defined characters such as XON, XOFF, or host commands conflicts with normal operation of these char- acters.
  • Page 232 15,000ms (15 sec.) Divide by 200 Scan ENTER/EXIT PROGRAMMING MODE Scan SELECT ACK NAK TIMEOUT VALUE SETTING Scan Two Characters From ‘0’ and ‘1’ ‘0’ and ‘5’ ‘2’ and ‘6’ ‘7’ and ‘5’ Appendix D, Keypad Scan ENTER/EXIT PROGRAMMING MODE WDI4200...
  • Page 233 RS-232 Parameters ACK NAK Retry Count This feature specifies the number of times the scanner retries a label transmis- sion due to a retry condition. The selectable range is from 1 to 254 retries. A selection of 0 disables the count, and a selection of 255 specifies unlimited retries.
  • Page 234 0x44 0xFF Chart on page 297 Scan ENTER/EXIT PROGRAMMING MODE Scan SELECT DISABLE CHARACTER VALUE SETTING Scan Two Characters From ‘6’ and ‘4’ ‘7’ and ‘D’ ‘4’ and ‘4’ ‘F’ and ‘F’ Appendix D, Keypad Scan ENTER/EXIT PROGRAMMING MODE WDI4200...
  • Page 235 RS-232 Parameters Enable Character Specifies the value of the RS-232 host command used to enable the scanner. ASCII characters or any hex value from 0 to 0xFF can be selected. Setting to previously defined characters such as XON, XOFF, or host com- mands conflicts with normal operation of these characters.
  • Page 236: Keyboard Interface

    Divide by 10 (and pad with leading zeroes) Scan ENTER/EXIT PROGRAMMING MODE Scan SELECT WEDGE QUIET INTERVAL SETTING Scan Two Characters From ‘0’ and ‘1’ ‘1’ and ‘5’ ‘6’ and ‘0’ ‘8’ and ‘5’ Appendix D, Keypad Scan ENTER/EXIT PROGRAMMING MODE WDI4200...
  • Page 237: Intercharacter Delay

    Keyboard Interface Intercharacter Delay This parameter specifies the intercharacter delay between the end of one char- acter and the beginning of the next. The delay can be set within a range of zero (0) to 990 milliseconds in 10ms increments. A setting of zero specifies no delay.
  • Page 238: Intercode Delay

    60 Seconds 99 Seconds Pad with leading zero(es) Scan ENTER/EXIT PROGRAMMING MODE Scan SELECT INTERCODE DELAY SETTING Scan Two Characters From ‘0’ and ‘0’ ‘0’ and ‘5’ ‘6’ and ‘0’ ‘9’ and ‘9’ Appendix D, Keypad Scan ENTER/EXIT PROGRAMMING MODE WDI4200...
  • Page 239: Data Format

    Data Format Data Format Data Editing When a bar code is scanned, additional information can be sent to the host computer along with the bar code data. This combination of bar code data and supplementary user-defined data is called a “message string.” The Data Editing features can be used to build specific user-defined data into a message string.
  • Page 240: Global Prefix/Suffix

    4. If less than the expected string of 20 characters are selected, scan the ENTER/EXIT bar code to terminate the string. 5. Scan the ENTER/EXIT bar code once again to exit Programming Mode. 6. The resulting message string would appear as follows: Scanned bar code data: 12345 Resulting message string output: $12345 WDI4200...
  • Page 241: Global Aim Id

    Data Format Global AIM ID This feature enables/disables addition of AIM IDs for all symbology types. NOTE AIM label identifiers (as opposed to custom characters you select yourself as with label identifiers) can be included with scanned bar code data. AIM label identifiers consist of three characters as follows: •...
  • Page 242: Label Id

    DATALOGIC 2OF5 730000 730000 EAN13 460000 420000 EAN13 P2 460000 4C0000 EAN13 P5 460000 4D0000 EAN8 464600 410000 EAN8 P2 464600 4A0000 EAN8 P5 464600 4B0000 FOLLETT 2OF5 4F0000 4F0000 GS1 DATABAR EXPANDED 525800 740000 GS1 DATABAR LIMITED 524C00 760000 WDI4200...
  • Page 243 Data Format Symbology USA Label ID set EU Label ID set GS1 DATABAR OMNIDIRECTIONAL 523400 750000 GS1-128 000000 6B0000 I2OF5 690000 4E0000 IATA 494100 & 260000 Industrial 2 of 5 570000 570000 Interleaved 2 of 5 CIP HR 650000 650000 ISBN 490000 400000...
  • Page 244 7. Scan the ENTER/EXIT bar code once again to exit Programming Mode. This completes the steps to configure a Label ID for a given symbology. Figure 10. Label ID Position Options Prefix Label ID Aim ID Bar Code Data Label ID Suffix WDI4200...
  • Page 245 Data Format Label ID: Set Individually Per Symbology — continued Table 13. Label ID Examples STEP ACTION EXAMPLES Scan the ENTER/EXIT bar (Scanner enters Programming Mode) code Determine placement of the Label ID characters BEFORE or AFTER with regard to Enable as Prefix Enable as Suffix Enable as Prefix Enable as Suffix scanned data using "Label...
  • Page 246: Character Conversion

    5. Scan the ENTER/EXIT bar code to exit Programming Mode. If less than the expected string of 16 characters are selected, scan the ENTER/EXIT bar code twice to accept the selections and exit Program- ming Mode. NOTE WDI4200...
  • Page 247: Scanning Features

    Scanning Features Scanning Features Scan Mode Selects the scan operating mode for the reader. Selections are: When the trigger is pulled, scanning is activated until one of the Trigger Single: following occurs: • Scanning Active Time has elapsed • a label has been read •...
  • Page 248: Scanning Active Time

    Pad leading zero(es) Scan ENTER/EXIT PROGRAMMING MODE Scan SELECT SCANNING ACTIVE TIME SETTING Scan Three Characters From ‘0’, ‘0’ and ‘1’ ‘0’, ‘9’ and ‘0’ ‘1’, ‘8’ and ‘0’ ‘2’, ‘5’ and ‘5’ Appendix D, Keypad Scan ENTER/EXIT PROGRAMMING MODE WDI4200...
  • Page 249: Flash On Time

    Scanning Features Flash On Time This feature specifies the ON time for the indicator LED while in Flash Mode. The selectable range is 100 to 9,900 milliseconds (0.1 to 9.9 seconds), in 100 millisecond increments. Follow these instructions to set this feature. 1.
  • Page 250: Flash Off Time

    Scan ENTER/EXIT PROGRAMMING MODE Scan SELECT FLASH OFF TIME SETTING Scan Two Characters From ‘0’ and ‘5’ ‘1’ and ‘0’ ‘5’ and ‘2’ ‘9’ and ‘9’ Appendix D, Keypad Scan ENTER/EXIT PROGRAMMING MODE WDI4200...
  • Page 251: Symbologies

    Symbologies Symbologies Set Length Length Control allows you to select either variable length decoding or fixed length decoding for the specified symbology. For variable length decoding, a minimum and maximum length Variable Length: may be set. For fixed length decoding, two different lengths may be set. Fixed Length: Set Length 1 This feature specifies one of the bar code lengths for a given symbology.
  • Page 252 07 Characters 52 Characters 74 Characters length) Scan ENTER/EXIT PROGRAMMING MODE Scan SELECT LENGTH 2 SETTING Scan Two Characters From ‘0’ and ‘0’ ‘0’ and ‘7’ ‘5’ and ‘2’ ‘7’ and ‘4’ Appendix D, Keypad Scan ENTER/EXIT PROGRAMMING MODE WDI4200...
  • Page 253: Technical Specifications

    Appendix A Technical Specifications The table below contains Physical and Performance Characteristics, User Envi- ronment and Regulatory information. provides Standard Cable Pinouts. Table 21 Table 19. Technical Specifications Item Description Electrical Features Power Supply 5 Vdc  10% RS-232 interface Operating (Typical): 170 mA @ 5 VDC Consumption: Standby/Idle (Typical): 90 mA @ 5 VDC...
  • Page 254 -20 C to + 70 C (-4° to +158 °F) Storage Temperature Humidity 90% non condensing IEC 68-2-32 Test ED Drop Resistance 1.5 m (5 ft) ESD Protection 16 KV Protection Class IP42 Weight  approx. 120 g (4.2 oz) (without cable) Cable Length Refer to www.waspbarcode.com WDI4200...
  • Page 255 PZN; Plessey; Anker Plessey; GS1 DataBar Omnidirectional; GS1 DataBar Limited; GS1 DataBar Expanded; GS1 DataBar Truncated; DATABAR Expanded Coupon. 2D / Stacked Codes The WDI4200 scanner is capable of decoding the following symbologies using multiple frames (i.e. Multi-Frame Decoding): Datamatrix; Inverse Datamatrix; Datamatrix is configurable for the following parameters:;...
  • Page 256: Led And Beeper Indications

    ROM Failure 200 mS. Imager ' c hirps' six times at Limited Scanning Limited Scanning the highest frequency and Label Read Label Read current volume. The LED blinks continuously Imager Disabled Imager Disabled 100mS on / 900 mS off WDI4200...
  • Page 257: Programming Mode

    LED and Beeper Indications Programming Mode The following indications ONLY occur when the scanner is in Programming Mode. INDICATION DESCRIPTION SPEAKER Label Program- A valid programming label has Scanner sounds four low fre- ming Mode LED blinks continuously been scanned. quency beeps.
  • Page 258: Troubleshooting

    Bar code is decoded but not trans- Imager not programmed for the Scan the appropriate host type bar code. mitted to the host. correct host type. Refer to the PRG for more information. WDI4200...
  • Page 259: Standard Cable Pinouts

    Standard Cable Pinouts Standard Cable Pinouts Figure 11 and provide standard pinout information for the scanner’s Table 21 cable. Figure 11. Standard Cable Pinouts Interface Cable Port Pin 10 Pin 1 Cable To Host Cable Strain Relief Cable Clip (Latch) The signal descriptions in apply to the connector on the scanner and Table 21...
  • Page 260 Technical Specifications NOTES WDI4200...
  • Page 261: Standard Defaults

    Appendix B Standard Defaults The most common configuration settings are listed in the “Default” column of the table below. Page references are also provided for feature descriptions and programming bar codes for each parameter. A column has also been provided for recording of your preferred default settings for these same configurable features.
  • Page 262 READING PARAMETERS Double Read Timeout 0.6 Second Power On Alert Power-up Beep Good Read: When to Indicate After Decode Good Read Beep Type Mono Good Read Beep Frequency High Good Read Beep Length 80 ms Good Read Speaker Volume High WDI4200...
  • Page 263 Page Parameter Default Your Setting Number Enable/Disable Good Read Indicator 300 ms SCANNING FEATURES Scan Mode Trigger Single Stand Mode Sensitivity Medium Scanning Active Time 5 Seconds Flash On Time 10 = Flash is ON for 1 Sec- Flash On Time 06 = Flash is OFF for Flash Off Time 600ms...
  • Page 264 Code 39 Full ASCII Disable Small Quiet Zones on two Code 39 Quiet Zones sides Code 39 Length Control Variable Code 39 Set Length 1 Code 39 Set Length 2 Code 32 (Italian Pharmaceutical Code) Code 32 Enable/Disable Disable WDI4200...
  • Page 265 Page Parameter Default Your Setting Number Code 32 Check Character Transmission Don’t Send Code 32 Start/Stop Character Trans- Don’t Transmit mission Code 39 CIP (French Pharmaceutical Code) Code 39 CIP Enable/Disable Disable Special Codes Code 128 Code 128 Enable/Disable Enable Expand Code 128 to Code 39 Don’t Expand Code 128 Check Character Transmis-...
  • Page 266 Industrial 2 of 5 Check Character Enable Transmission Industrial 2 of 5 Length Control Variable Industrial 2 of 5 Set Length 1 Industrial 2 of 5 Set Length 2 Code IATA IATA Enable/Disable Disable IATA Check Character Transmission Enable WDI4200...
  • Page 267 Page Parameter Default Your Setting Number Codabar Codabar Enable/Disable Disable Codabar Check Character Calculation Don’t Calculate Codabar Check Character Transmission Send Codabar Start/Stop Character Trans- Transmit mission Codabar Start/Stop Character Set abcd/abcd Codabar Start/Stop Character Match Don’t Require Match Small Quiet Zones on two Codabar Quiet Zones sides Codabar Length Control...
  • Page 268 Code 93 Set Length 2 Small Quiet Zones on two Code 93 Quiet Zones sides MSI Enable/Disable Disable MSI Check Character Calculation Enable Mod10 MSI Check Character Transmission Enable MSI Length Control Variable MSI Set Length 1 MSI Set Length 2 WDI4200...
  • Page 269: Default Exceptions

    Default Exceptions Default Exceptions Table 23. Default Exceptions by Interface Type Default Parameter Exception Interfaces: USB-OEM Global Suffix No Global Suffix Double Read Timeout 500 msec Interfaces: All Keyboard Wedge, USB Keyboard No unique settings Interface: RS232-WN Expand UPC-A to EAN-13 Enable UPC-E Check Character Transmission Disable...
  • Page 270 Code 32 Label ID Character(s) Interleaved 2of5 Label ID Character(s) Code Standard 2/5 Label ID Character(s) Codabar Label ID Character(s) Code 11 Label ID Character(s) Code 128 Label ID Character(s) GS1-128 Label ID Character(s) UPCA/P2 Label ID Character(s) UPCA/P5 Label ID Character(s) WDI4200...
  • Page 271 Default Exceptions Default Parameter Exception UPCA/GS1-128 Label ID Character(s) UPCE P2 Label ID Character(s) UPCE/P5 Label ID Character(s) EAN8/P2 Label ID Character(s) EAN8/P5 Label ID Character(s) EAN8/GS1-128 Label ID Character(s) EAN13/P2 Label ID Character(s) EAN13/P5 Label ID Character(s) EAN13/GS1-128 Label ID Character(s) GS1 DataBar 14 (Omnidirectional) Label ID Character(s) GS1 DataBar Expanded Label ID Character(s) GS1 DataBar Limited Label ID Character(s)
  • Page 272 Standard Defaults NOTES WDI4200...
  • Page 273: Sample Bar Codes

    Appendix C Sample Bar Codes The sample bar codes in this appendix are typical representations for their symbology types. 1D Bar Codes UPC-A EAN-13 978033029095 Code 39 Code 128 Code 128 Interleaved 2 of 5 Product Reference Guide...
  • Page 274 Sample Bar Codes Sample Bar Codes (continued) Code 32 Codabar 13579 Code 93 Code 11 123456789 WDI4200...
  • Page 275: Gs1 Databarâ„¢ (Rss)

    GS1 DataBar™ (RSS) GS1 DataBar ™ GS1 DataBar™ variants must be enabled to read the bar codes below (see " Omnidirectional" on page 129 GS1 DataBar™ Expanded Stacked 10293847560192837465019283746029478450366523 GS1 DataBar™ Expanded 1234890hjio9900mnb GS1 DataBar™ Limited 08672345650916 GS1 DataBar™-14 GS1 DataBar™ Omnidirectional Truncated 55432198673467 GS1 DataBar™...
  • Page 276 Sample Bar Codes 2D Bar Codes Aztec Datamatrix China Sensible Code MaxiCode Test Message PDF 417 Micro PDF 417 ABCabc BV17453 QR Code Micro QR Code 123456 35900G9 UCC Composite WDI4200...
  • Page 277: Keypad

    Appendix D Keypad Use the bar codes in this appendix to enter numbers as you would select digits/characters from a keypad. Product Reference Guide...
  • Page 278 Keypad QuickScan™ Lite QW2400...
  • Page 279: Scancode Tables

    Appendix E Scancode Tables Control Character Emulation Control character emulation selects from different scancode tables as listed in this appendix. Each of the control character sets below are detailed by interface type in the tables. These apply to Wedge and USB Keyboard platforms.
  • Page 280: Interface Type Pc At Ps/2 Or Usb-Keyboard

    ð ñ ò ó ô õ ö ÷ ø ù ú û ü ý þ ÿ Extended characters (sky blue) are sent through dedicated keys (when available in the selected country mode) or by using an Alt Mode sequence. WDI4200...
  • Page 281 Interface Type PC AT PS/2 or USB-Keyboard (continued) Table 25. Scancode Set When Control Character is 02 Enter Ar↓ Ar↑ Al↓ Al ↑ Cl ↓ Cl ↑ Cr ↓ Cr ↑  S+ Tab Enter Pg Up Keypd Pg Dwn Home ...
  • Page 282: Interface Type Pc At Ps/2 Alt Mode Or Usb-Keyboard Alt Mode

    A+0217 A+0218 A+0219 A+0220 A+0221 A+0222 A+0223 A+0224 A+0225 A+0226 A+0227 A+0228 A+0229 A+0230 A+0231 A+0232 A+0233 A+0234 A+0235 A+0236 A+0237 A+0238 A+0239 A+0240 A+0241 A+0242 A+0243 A+0244 A+0245 A+0246 A+0247 A+0248 A+0249 A+0250 A+0251 A+052 A+0253 A+0254 A+0255 WDI4200...
  • Page 283 Interface Type PC AT PS/2 Alt Mode or USB-Keyboard Alt Mode (continued) Table 27. Scancode Set When Control Character is 02 Enter Ar↓ Ar↑ Al↓ Al ↑ Cl ↓ Cl ↑ Cr ↓ Cr ↑  S+ Tab Enter Pg Up Keypd Pg Dwn Home...
  • Page 284: Microsoft Windows Codepage 1252

    Scancode Tables Microsoft Windows Codepage 1252 Windows-1252 is a character encoding of the Latin alphabet, used by default in the legacy components of Microsoft Windows in English and some other Western languages.
  • Page 285: Index

    Index Symbols 220, 223, Expand Good Read, Beeper Pitch Volume Good Read, Beeper – Good Read, Beeper Pitch – bar codes Good Read, Beeper Volume – RS-232 baud rate RS-232 parameters parity barcodes Handheld Scanner cancel numeric barcodes RS-232 parameters parity Indications Beeper...
  • Page 286 Read, Beeper – Good Read, Beeper Pitch – Good Read, Beeper Volume – Good Request to Send RS-232 interface selection sample barcodes code 128 code 39 interleaved 2 of 5 Scancode Tables select digits/characters Serial Output Standard Cable Pinouts Suffix Symbologies symbology types Table Top Scanner...
  • Page 287: Ascii Chart

    ASCII Chart ASCII ASCII ASCII ASCII Char. Char. Char. Char. ‘ “ & ’ < >...
  • Page 288 Wasp Barcode Technologies 1400 10 Street Plano, Texas USA 75074 ©2013-2018 Wasp Barcode Technologies 8200XXXXX (Rev A) Aug 2018...

Table of Contents