Advertisement

Quick Links

User Manual: Atlas +
+34 976 96 69 94
spherag.com
@spherag
contact@spherag.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Atlas+ and is the answer not in the manual?

Questions and answers

Summary of Contents for spherag Atlas+

  • Page 1 User Manual: Atlas + +34 976 96 69 94 spherag.com @spherag contact@spherag.com...
  • Page 2: Table Of Contents

    OPERATION ........................... 8 ACTION ............................ 8 MONITORING ......................... 9 ALERTS AND NOTIFICATIONS ....................11 INSTALLATION AND FIRST STEPS ..................13 TROUBLESHOOTING ........................16 GLOSSARY OF TERMS ......................18 PRODUCT RECYCLING......................19 WARRANTY ..........................20 EXPLANATION OF THE SYMBOLOGY ................21 +34 976 96 69 94 spherag.com @spherag contact@spherag.com...
  • Page 3: Description Of The Device

    The control and management of all the functionalities available for the ATLAS PLUS device can be done from the SPHERAG platform. https://portal.spherag.com/ +34 976 96 69 94 spherag.com...
  • Page 4: Parts Of The Device

    9. Output connector 1 to 4. 10. Output connector 5 to 8. 11. Input connector 1 to 4. 12. Sensor connector I 13. SDI-12 sensor connector. 14. Connection cables for outputs and inputs. +34 976 96 69 94 spherag.com @spherag contact@spherag.com...
  • Page 5: Technical Specification

    Outputs 8 (Latch relay or latch solenoid) Output voltage 14 Vdc Sensor input 1 (I C), 1 (SDI-12) Remote configuration Spherag Platform - Searching: 1 flash/sec - Connecting: 1 flash/sec Led indicator - Connected: no flash - Communicating: 1 flash/sec...
  • Page 6: Mechanical Specifications

    Minimum voltage 3.4 Vdc Nominal voltage 3.7 Vdc Nominal current 8 mA Voltage solar cell 5 Vdc Current solar cell 340 mA Two in case the device has only four outputs enabled +34 976 96 69 94 spherag.com @spherag contact@spherag.com...
  • Page 7: Sending Data

    45% ~ 75% RH Working height 0 ~ 2000 m Storage temperature -20 ~ +50 ºC Storage humidity 45% ~ 75% RH Storage height 0 ~ 2000 m Please contact us for other synchronization options +34 976 96 69 94 spherag.com @spherag contact@spherag.com...
  • Page 8: Operation

    Figura 1. Outputs and inputs of the ATLAS PLUS device. In order to facilitate the user experience, we recommend connecting the cables in one of the ways shown in Figure 2.1. Figure 2. +34 976 96 69 94 spherag.com @spherag contact@spherag.com...
  • Page 9: Monitoring

    Figure 2. Connection of inputs and outputs. After registering the device on the SPHERAG platform, the functionality to be associated with each output can be selected, as well as its mode: manual or automatic. As mentioned above, each output can be used in manual or automatic mode. That is, it...
  • Page 10 In order to receive the information from these elements, they must be registered in the SPHERAG platform, as is the case with the rest of the elements connected to the outputs, inputs or sensors of the device. That is to say, through these devices, the device +34 976 96 69 94 spherag.com...
  • Page 11: Alerts And Notifications

    (Out of range time). If the pressure goes out of the marked pressure range for longer than the set time, the user will receive a notification indicating a problem in the installation. +34 976 96 69 94 spherag.com @spherag contact@spherag.com...
  • Page 12 To avoid false pressure alerts appearing during these minutes of filling the pipe, this time can be added to the Monitoring time. NOTE: If this time interval is not required, it can be set to 0. +34 976 96 69 94 spherag.com @spherag contact@spherag.com...
  • Page 13: Installation And First Steps

    Connect the selected output or input cable (red, green, white or yellow) and the common (black) cable (Figure 1) to the wires of the solenoid or pulse emitter of the fixture (Figure 4). +34 976 96 69 94 spherag.com @spherag contact@spherag.com...
  • Page 14 Figure 6. 3 way valve, “AUTO” position. Unscrew the waterproof cap covering the adapter for the device's sensor connector. Connect the sensor to the device and close the safety thread. Se adquieren por separado. +34 976 96 69 94 spherag.com @spherag contact@spherag.com...
  • Page 15 7 hours per day. Do not cut or manipulate the cable of any sensor in order to reduce or extend its distance. Figure 7. ATLAS PLUS placement. +34 976 96 69 94 spherag.com @spherag contact@spherag.com...
  • Page 16: Troubleshooting

    Turn off the device and keep it for 4-5 days in Battery depleted. direct sunlight for at least 6 hours. Then turn the device on again. +34 976 96 69 94 spherag.com @spherag contact@spherag.com...
  • Page 17 Place it in a high place, so that the quality of due to poor signal the coverage is better. quality. Contact Spherag technical support: Device failure due to a possible short cir- - Phone: +34 684 464 107 cuit.
  • Page 18: Glossary Of Terms

    16. Pins: These are the connection terminals on an electronic device that are used to con- nect it to other devices or components within an electrical circuit, in this case to the connector. +34 976 96 69 94 spherag.com @spherag contact@spherag.com...
  • Page 19: Product Recycling

    For detailed information about the most appropriate way to dispose of your appliances and/or the corresponding batteries, the consumer should contact the local authorities. +34 976 96 69 94 spherag.com @spherag contact@spherag.com...
  • Page 20: Warranty

    8. WARRANTY Consult the General Warranty and Repair Conditions of our devices through the following link: https://spherag.com/general-warranty-and-repair-conditions/ +34 976 96 69 94 spherag.com @spherag contact@spherag.com...
  • Page 21: Explanation Of The Symbology

    Official Journal of the Euro- pean Communities. Responsible within the Euro- pean Union: SPHERAG TECK IOT S.L. Av. Alcalde Gómez Laguna, 25, Planta 10, Oficina B1, 50009 Zaragoza To identify the location where the operating instruc- tions are stored or to identify information related to the operating instructions.

Table of Contents