INSTALLATION INSTRUCTIONS
7HP14F
This is a safety alert symbol and should never be ignored. When you see this symbol on labels or in manuals, be
alert to the potential for personal injury or death.
Improper installation, adjustment, alteration, service or
maintenance can cause property damage, personal
injury or loss of life. Installation and service must be
performed by a licensed professional HVAC installer or
equivalent, or service agency.
IMPORTANT: Special procedures are required for clean-
ing the all-aluminum coil in this unit. See page 20 in this
instruction for information.
General
This 7HP14F outdoor heat pump with all-aluminum coil
is designed for use with R-454B refrigerant only. This unit
must be installed with an approved indoor air handler or
coil. For AHRI Certified system match-ups and expand-
ed ratings, visit www.AlliedAir.com. These instructions are
intended as a general guide and do not supersede local
codes in any way. Consult authorities having jurisdiction
before installation.
STEP 1 – SETTING THE UNIT – Clearances
See NOTES
See
NOTES
See NOTES
Allied Air Enterprises LLC
215 Metropolitan Drive
West Columbia, SC 29170
508424-01
This manual must be left with the homeowner for future reference
WARNING
See
NOTES
CONTROL
BOX
Charging information is given on the charging
procedure sticker on the unit access panel. For
more in-depth information, consult the Installation
and Service Procedures manual.
As with any mechanical equipment, contact with sharp
sheet metal edges can result in personal injury. Take
care while handling this equipment and wear gloves and
protective clothing.
NOTE – This unit 7HP14F is a PARTIAL UNIT AIR CON-
DITIONER, complying with PARTIAL UNIT requirements
of this Standard, and must only be connected to other
units that have been confirmed as complying to corre-
sponding PARTIAL UNIT requirements of this Standard,
UL 60335-2-40/CSA C22.2 No. 60335-2-40, or UL 1995/
CSA C22.2 No 236.
NOTES -
Service clearance of 30 in. (762 mm) must be maintained on one of
the sides adjacent to the control box.
Clearance to one of the other three sides must be 36 in. (914 mm).
Clearance to one of the remaining two sides may be 12 in. (305
mm) and the final side may be 6 in. (152 mm).
A clearance of 24 in. must be maintained between two units.
48 in. (1219 mm) clearance required on top of unit.
Issue 2521
Single Stage Heat Pump
NOTICE!
CAUTION
*P508424-01*
(P) 508424-01
Page 1 of 23