“product”) are the result of targeted development and meticulous research. From the date of delivery, burster provides a warranty for the proper condition and functioning of these products covering material and production defects for the period specified in the warranty document accompanying the product.
Contents For your safety ............................. 6 Symbols used in the operation manual ..................6 1.1.1 Signal words ........................6 1.1.2 Pictograms ........................6 Introduction ............................7 Intended use ..........................7 2.1.1 Customer service department ..................7 2.1.2 Contact person ......................... 7 Download the test certificate ......................
Page 5
5.3.1.1 Option 8427-xxxx-xxBxxxxx ................18 5.3.1.2 Option 8427-xxxx-xxTxxxxx ................20 5.3.1.3 Option 8427-xxxx-xxExxxxx ................20 5.3.1.4 Option 8427-xxxx-xxFxxxxx ................21 5.3.1.5 Option 8427-xxxx-xxHxxxxx ................21 Measurement chain calibration ....................... 22 Calibration using data from the test and calibration certificate ..........22 Shunt calibration ........................
Property damage to the equipment or the surroundings will result if the hazard is not avoided. Hinweis: It is important to heed these safety notices in order to ensure you handle the model 8427 tension and compression load cell correctly.
Intended use The load cells in the 8427 model series are primarily designed for the measurement of force in production equipment, using newtons (N) as the unit of measurement. The local gravitational acceleration (g ≈ 9.81 m/s²) must be taken into account when determining masses. Customer service 2.1.1 Customer service department...
EN 61558. 2.3.3 Restrictions on use The model 8427 tension and compression load cell does not pose a hazard if used within its specification and in accordance with the safety regulations.
Only ever use the model 8427 tension and compression load cell under the conditions specified in this operating manual. Inspect the model 8427 tension and compression load cell for damage. If you suspect that the device has been damaged during shipping, notify the delivery company within 72 hours.
Only the manufacturer’s own qualified personnel are permitted to open the model 8427 tension and compression load cell. It is not permitted to make any changes to the model 8427 tension and compression load cell without the written agreement of burster präzisionsmesstechnik gmbh & co. kg. burster präzisionsmesstechnik gmbh &...
Concept and general information Please refer to the data sheet for the model 8427 precision tension and compression load cell for full details of dimensions, weight, degree of protection etc. Mechanical design In the model 8427 tension and compression load cell, the spring element is designed as a horizontally oriented elastic membrane with a centrally arranged ring.
: Reference excitation voltage • c: Rated output of the load cell You can find the rated output “c” on the test certificate for the model 8427 tension and compression load cell. It is typically in the region of approx. 1.1 mV.
EN 61558. Hinweis: Transmitters connected to the outputs or other devices that are galvanically connected to the signal lines of the model 8427 tension and compression load cell must also be fitted with safety transformers to EN 61558.
WICHTIG: Prevent torsional moments, lateral forces and bending forces. Application of force 1. Apply the force being measured to the model 8427 tension and compression load cell via the central thread. 2. Apply the force centrically exactly along the axis of symmetry.
Page 15
You can recognize an overload from an increased output signal at no load. Bending plates are relatively insensitive to overloading. Hinweis: Check the model 8427 tension and compression load cell if the signal increases by more than approx. 5 %...
Fixing method The entire contact surface of the model 8427 tension and compression load cell must lie on a hardened (min. 58 HRC), flat, ground or lapped mounting surface. The load cell is designed for universal use with a wide range of fixing options.
Electrical system, evaluation instrumentation The output signal from the model 8427 tension and compression load cell, with an excitation voltage of 5 V, is 7.5 mV max. Therefore for a measurement accuracy of 0.5 % you will need a resolution of approx.
5.3.1 Connector pin assignment The model 8427 tension and compression load cell is supplied with an open cable end. The model 8427 tension and compression load cell is optionally fitted with connectors for burster display and calibration equipment. Hinweis: For optionally supplied display and calibration devices, please follow the operating instructions for the device to ensure compatibility.
Page 19
Figure 6: Device connection Figure 7: 9-pin connection with 6-wire system of 26...
5.3.1.2 Option 8427-xxxx-xxTxxxxx Connection to burster devices with 9-pin D-sub socket with 6-wire system with burster TEDS. Figure 8: Device connection Figure 9: Connection to 9-pin burster TEDS 5.3.1.3 Option 8427-xxxx-xxExxxxx Connection to burster devices with 9-pin D-sub socket with 4-wire system for 9163-V3xxx.
Calibration with a physical variable A known physical quantity is applied to the model 8427 tension and compression load cell, and the entire measurement chain consisting of the model 8427 tension and compression load cell and instrumentation amplifier or digital indicator is calibrated.
Calibration with a precision voltage source The model 8427 tension and compression load cell is calibrated using a high-precision voltage source (e.g. burster TRANS CAL 7281-V0001, DIGISTANT model 4423).
Technical data Please refer to the enclosed data sheet for the technical specification. The latest version of the data sheet is available at https://www.burster.com/en/load-cells/p/detail/8427 or simply use the following QR code: Figure 16: Technical data QR code Electromagnetic compatibility 7.1.1 Interference immunity...
Accessories available Please refer to the enclosed data sheet for details of the accessories available. The latest version of the data sheet is available at https://www.burster.com/en/load-cells/p/detail/8427 or simply use the following QR code: Figure 17: Accessories available of 26...
Disposal Instrument disposal If your instrument is no longer usable, please comply with your legal obligations by disposing of the instrument described here in accordance with statutory regulations. You will then be helping to protect the environment! of 26...