Table of Contents Table of Contents Introduction ............................3 Important user information ................................4 About this manual ....................................5 Associated documentation ................................6 Safety instructions ..........................7 Safety precautions ....................................8 Labels and symbols ....................................11 System description ..........................12 Product overview ....................................
1 Introduction 1 Introduction About this chapter This chapter contains information about this manual and associated user documentation, important user information, and intended use of the product. In this chapter Section See page Important user information About this manual Associated documentation Sentino microbiology pump Operating Instructions 89724 AA...
1 Introduction 1.1 Important user information 1.1 Important user information Introduction This section contains important user information about the product and this manual. Read this before operating the product All users must read the entire Operating Instructions before installing, operating, or main- taining the product.
1 Introduction 1.2 About this manual 1.2 About this manual Introduction This section contains information about the purpose and scope of this manual, notes and tips, and typographical conventions. Purpose of this manual This manual provides information needed to install, operate, and perform maintenance in a safe way. Scope of this manual This manual is valid for Sentino microbiology pump.
1 Introduction 1.3 Associated documentation 1.3 Associated documentation Access user documentation online Scan the QR code or visit cytiva.com/instructions. Enter the title or the document number to access the file. Sentino microbiology pump Operating Instructions 89724 AA...
2 Safety instructions 2 Safety instructions About this chapter This chapter describes safety precautions, labels, and symbols. In this chapter Section See page Safety precautions Labels and symbols Important WARNING All users must read and understand the entire contents of this general safety chapter, and the specific safety precau- tions information in each subsequent chapter of this manual to become aware of the hazards involved.
2 Safety instructions 2.1 Safety precautions 2.1 Safety precautions Introduction This section describes the general hazards you must be aware of before performing installation, operation, or maintenance. Definitions This user documentation contains safety notices (WARNING, CAUTION, and NOTICE) concerning the safe use of the product.
Page 9
2 Safety instructions 2.1 Safety precautions WARNING Use of personal protective equipment, such as gloves, gowns, labo- ratory coats, and protective eyewear, help to reduce risk of expo- sure and is recommended. WARNING Proper disposal of fluid paths in accordance with biohazard safety procedures is recommended where applicable.
Page 10
2 Safety instructions 2.1 Safety precautions NOTICE Sanitization of equipment as directed in this manual is essential for maintaining optimum performance. NOTICE Keypad buttons on this product intended for finger touch only. NOTICE Only use recommended solutions for cleaning and sanitization. NOTICE The unit is always on standby with battery power.
2 Safety instructions 2.2 Labels and symbols 2.2 Labels and symbols Introduction This section describes the nameplate, labels, and other safety and regulatory labels and symbols. Nameplate The nameplate provides information about the model, manufacturer, and technical data. Description of symbols and text The following symbols and text can be present on the nameplate: Symbol / text Description...
3 System description 3 System description About this chapter This chapter gives an overview of Sentino microbiology pump and a brief description of its function. In this chapter Section See page Product overview Product description Keypad and symbols Sentino microbiology pump Operating Instructions 89724 AA...
3 System description 3.1 Product overview 3.1 Product overview The membrane filtration (MF) technique is a method of analyzing aqueous samples for microbial contamination. A fluid sample is pulled through a membrane filter and the filter is placed on growth media and incubated.
3 System description 3.2 Product description 3.2 Product description Front of the product and keypad Part Description Stage with adapter guide Battery status indicator Fault indicator Pulse button Main power indicator Power On/Off button Drive tube guide Sentino microbiology pump Operating Instructions 89724 AA...
Page 15
3 System description 3.2 Product description Back of the product Part Description Power socket Nameplate Pump head and fluid path Part Description Filter funnel adapter Loading door Slot for drive tube Drive tube Sentino microbiology pump Operating Instructions 89724 AA...
3 System description 3.2 Product description Power cords Part Description Transformer power plug Power cord Transformer input interface Sentino microbiology pump Operating Instructions 89724 AA...
3 System description 3.3 Keypad and symbols 3.3 Keypad and symbols Symbol Description Function Main power indicator A green LED illuminates when the pump is plugged into the power transformer and VAC power source. This LED is not illuminated when operating on battery power.
4 Preparation 4 Preparation About this chapter This chapter gives the required information to set up and prepare Sentino microbiology pump for operation. In this chapter Section See page Connecting power supply and charging Fluid path installation Sentino microbiology pump Operating Instructions 89724 AA...
4 Preparation 4.1 Connecting power supply and charging 4.1 Connecting power supply and charging Step Action Position the Sentino microbiology pump on a laboratory bench. Attach power plug from power transformer into the power socket, as shown in the image below.
4.2 Fluid path installation 4.2 Fluid path installation The Sentino microbiology pump is designed to interface with disposable fluid path from Cytiva. The fluid path remains secure during filter funnel loading and unloading. A guide on the pump housing helps position the tubing correctly inside the device without the use of any tools.
Page 21
4 Preparation 4.2 Fluid path installation Step Action Slide adapter into the guide on the pump housing, as shown in the image below, until the adapter is firmly seated. Tuck the tubing into the slot in the pump head and position the tube into the guide slot in the base, as shown in the image below.
5 Operation 5 Operation About this chapter This chapter gives instructions on how to operate Sentino microbiology pump in a safe way. In this chapter Section See page Safety precautions Filtration Sentino microbiology pump Operating Instructions 89724 AA...
5 Operation 5.1 Safety precautions 5.1 Safety precautions CAUTION If the loading door is open during operation, rotation of the rollers can present an accessible pinch point to the user. Note: If the loading door is open during operation, no filtration or pumping will occur. Note: The operation is the same whether powered by the internal battery or using the power transformer and power cord.
5.2 Filtration 5.2 Filtration Step Action Place Cytiva filter funnel onto adapter on pump stage. Pour sample into filter funnel. For continuous operation: a. To start filtration, press and release the power On/Off button b. To stop filtration, press and release the power On/Off button again For pulse or momentary operation: a.
The device utilizes a peristaltic pump drive which can cause a pinch point if operated with the loading door open. NOTICE The device is designed for use with fluid path from Cytiva only. NOTICE The unit is always on standby with battery power. Do not press the power or pulse buttons while loading fluid path.
Page 26
6 Maintenance • 10% bleach Sanitizing the fluid path The fluid path must be changed at least once a week. For optimal contamination control, daily replacement of fluid path is recommended. Upon initial installation of the fluid path: Step Action Run 70% IPA through the fluid path for 5 seconds.
If the suggested actions in this guide do not solve the problem, or if the problem is not covered by this guide, contact your Cytiva representative for advice. Troubleshooting guide When this symbol on the unit is backed with a yellow LED, the device has sensed a condition in which performance has been impacted and the user must consult the Operating Instructions for troubleshooting.
Page 28
7 Troubleshooting Problem Cause Corrective action Pump head not rotating, Obstruction in pump head. • Check that drive tube slot in pump head is free of yellow fault indicator illumi- foreign objects. nated. • Verify that fluid path is properly loaded. See: Section 4.1 Connecting power supply and charging, on page 19 Section 4.2 Fluid path installation, on page 20...
8 Reference information 8 Reference information About this chapter This chapter lists technical specifications of Sentino microbiology pump. The chapter also includes recycling information, regulatory information, and ordering information. In this chapter Section See page Specifications Recycling information Regulatory information Ordering information Sentino microbiology pump Operating Instructions 89724 AA...
8 Reference information 8.1 Specifications 8.1 Specifications Introduction This section describes the specifications for the product. Materials of construction Parameter Specification Housing material Polycarbonate ABS-blended polymer Keypad and label Polyester Pump head PEI with PTFE-filled PBT rollers Fluid path adapter Polypropylene Hose material Thermoplastic elastomer...
8 Reference information 8.1 Specifications Battery Parameter Specification Voltage 12.0 V Type NiMH (nickel metal hydride) DC supply Parameter Specification Voltage 24.0 V AC/DC power transformer Parameter Specification Power 24 VDC 1.6 Amp, 100 to 240 VAC, 47 to 63 Hz Input interface IEC 320 3-pin socket Output interface (power plug)
When taking the product out of service, the different materials must be separated and recycled according to national and local environmental regulations. Recycling of hazardous substances The product contains hazardous substances. Detailed information is available from your Cytiva representative. Disposal of electrical components Waste electrical and electronic equipment must not be disposed of as unsorted municipal waste and must be collected separately.
8 Reference information 8.3 Regulatory information 8.3 Regulatory information Introduction This section lists the regulations and standards that apply to the product. Your product is marked or listed according to the applicable regulatory requirements for your region. Local language transla- tions are only provided according to regulatory requirements.
To find local contact information for support and sending troubleshooting reports, visit cytiva.com/ contact. Manufacturing information The table below summarizes the required manufacturing information. Requirement Information Name and address of manufacturer Cytiva Puerto Rico Pall Boulevard Road 194 KM 0.4 Fajardo, PR 00738 Sentino microbiology pump Operating Instructions 89724 AA...
8 Reference information 8.3 Regulatory information 8.3.2 European Union and European Economic Area 8.3.2 European Union and European Economic Area Introduction This section describes the information that applies to the product in the European Union and Euro- pean Economic Area. Conformity with EU Directives Refer to the EU Declaration of Conformity for the directives and regulations that apply for the CE marking.
8 Reference information 8.3 Regulatory information 8.3.3 South Korea 8.3.3 South Korea Introduction This section describes the information that applies to the product in the Republic of Korea. Compliance statement NOTICE Class A equipment (equipment for business use). This equipment has been evaluated for its suitability for use in a business environment.
8 Reference information 8.3 Regulatory information 8.3.4 General regulatory statements 8.3.4 General regulatory statements EMC emission, CISPR 11: Group 1, Class A statement NOTICE This equipment is not intended for use in residential environments and may not provide adequate protection to radio reception in such environments.
8 Reference information 8.4 Ordering information 8.4 Ordering information Part number Description 13186 1/pkg Sentino microbiology pump • Power transformer (1) • European power cord with CEE 7/7 plug (1) • Power cord with NEMA 5-15P plug (1) • UK power cord with BS1363 plug (1) •...