The Keysight U1115A Remote Logging display is designed to be used with the
Keysight U1200 Series handheld meters, Keysight U1117A IR-to-Bluetooth
Adapter, Keysight U1177A IR-to-Bluetooth Adapter and mobile/software
applications to provide you a total wireless remote connectivity solution.
With the U1115A, you can view readings from up to four handheld meters
simultaneously, from an extended distance of up to 100-metres (U1117A) within
the line-of-sight.
Keysight U1200
Series handheld
meters
Figure 1 Keysight wireless remote connectivity solution
Standard Shipped Items Checklist
The following items are included with your purchase:
U1115A Remote Logging Display.
Three 1.5 V AA batteries.
USB to micro USB cable (for external power only).
Operating Instructions (this booklet).
Soft Carrying Case.
The Bluetooth
word mark and logos are registered trademark owned by Bluetooth SIG, Inc and any
1
®
use of such marks by Keysight is under license. Other trademark and trade names are those of their
respective owners.
The Keysight U1115A only supports Keysight Handheld Meter Logger software for downloading logged data
2
to PC via Bluetooth connection.
U1117A IR-to-
Bluetooth adapter
U1177A IR-to-
Bluetooth adapter
U1115A remote
logging display
Windows PC
Android devices
iOS devices
1
2
Keysight PC Application Software
Keysight Handheld Meter
Logger
Keysight Mobile Application
Keysight Mobile Meter
Keysight Mobile Logger
®1
2
2

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the U1115-90103 and is the answer not in the manual?

Questions and answers

Summary of Contents for Keysight U1115-90103

  • Page 1 Bluetooth SIG, Inc and any ® use of such marks by Keysight is under license. Other trademark and trade names are those of their respective owners. The Keysight U1115A only supports Keysight Handheld Meter Logger software for downloading logged data...
  • Page 2: Product Characteristics

    Power Consumption Maximum 1 VA for 3 AA batteries Maximum 5 V +10 %, 250 mA for external power Auto Power Off mode, current consumption 3 mA Warranty One year (Does not cover normal wear and tear of mechanical parts and batteries) Bluetooth Bluetooth SPP profile, Class 1 device Compatibility Keysight Handheld Meter/Display: • Keysight U1200 Series Handheld Meters • Keysight U1117A IR-to-Bluetooth Adapter • Keysight U1177A IR-to-Bluetooth Adapter Keysight Application Software: • Keysight Handheld Meter Logger Hardware Device: • Windows PC (with Bluetooth-enabled) Regulatory The U1115A complies with the requirements of the following product standards: • EMC EN 301 489–1:V1.9.2...
  • Page 3 Regulatory • India Equipment Type Approval (ETA) Certificate No: NER-ETA/924 “This telecommunication equipment conforms to the NTC technical requirement” Table 1 Connectivity distance (approximate) within the line-of-sight U1177A U1117A U1115A U1177A – – 10 m U1117A – – 100 m U1115A 10 m 100 m – Other Class 1 devices 10 m 100 m 100 m Other Class 2 devices 10 m 10 m...
  • Page 4 • Canada IC: The device contains transmitter IC: 5123A–BGTWT11IA • To comply with FCC and Industry Canada RF radiation exposure limits for general population, the antenna(s) used for this transmitter must be installed such that a minimum separation distance of 20 cm is maintained between the radiator (antenna) and all persons at all times and must not be colocated or operating in conjunction with any other antenna or transmitter. • “La operación de este equipo está...
  • Page 5: Front View

    Front View Sampling annunciator Time indicator 01:01 Battery indicator F3 key HOLD MODE CONNECT SETTINGS Function keys Logger key Navigation keys Meter Logger Meter key Figure 2 Front view of the U1115A Remote Logging Display Side View Slide power switch Stand External power port (micro USB port) Figure 3 Side view of the U1115A Remote Logging Display (standing position)
  • Page 6: Back View

    Back View Slide power switch Stand Battery cover with magnetic holder Figure 4 Back view of the U1115A Remote Logging Display Turning On the U1115A To turn on the U1115A , set the slide power switch to On. (as shown in figure 4) • Once a connected IR-to-Bluetooth Adapter is turned off, below scenarios will occur : 1 The Not Connected annunciator will appear on the display.
  • Page 7: Installing And Replacing The Batteries

    Installing and Replacing the Batteries Make sure you turn off the U1115A before installing or replacing the batteries. To avoid the U1115A being damaged from battery leakage: • Always remove dead batteries immediately. • Always remove the batteries and store them separately if the U1115A is not going to be used for a long period of time. Remove the battery protective sheet before using for the first time.
  • Page 8: Connecting To Devices

    Connecting to Devices Ensure that the Link LED at the IR-to-Bluetooth adapter CONNECT is blinking before establishing a connection. Power cycle if necessary. Press to enter Connection Front view of the U1117A Manager. (U1115A) IR-to-Bluetooth adapter 01:01 Connection Manager Enter Scan A> Add Device B> Add Device C> Add Device D> Add Device Back Bluetooth Enter Press to scan for Press to add devices.
  • Page 9 Connecting to Devices (continued) Select Press to select the desired device. Typical connection menu display. • Select Connect to make a connection. • Select Cancel to cancel a connection. Press to navigate to desired • Select Pairing PIN : 1234 to change PIN number. Ensure that the U1115A function.
  • Page 10: Meter View

    Meter View 01:01 A> U1117A-57AE5B Not Connected A> U1117A-57AE5B U1273A-MY51430008 ----- HOLD MODE CONNECT SETTINGS Typical screen display when no meter is Typical screen display when one meter connected to the U1115A. is connected to the U1115A. U1117A-57AE5B A> U1273A-MY51430008 A>...
  • Page 11: Selecting Measurement Mode

    Identifying a Connected Meter The identify meter function allows you to easily identify your connected meter(s). To identify the connected meter, follow the steps below : 1 In the meter view, select the desired meter and press CONNECT. 2 Then, navigate to the desired connected device and press Identify. 3 The meter corresponds to the selected device will beep and flash it’s backlight.
  • Page 12 Performing Data Logging The data logging function provides you the convenience of recording test data for future review or analysis. Table 3 Data logging maximum capacity Data logging option Maximum storage capacity Manual log 500 pts Interval log 60 000 pts/100 sessions For interval log, a maximum of 60 000 points or 100 sessions can be stored, whichever occurs first. Session ends when the U1115A powers off, count mode ends, restarts new logging or all connected meter(s) disconnect Performing Manual Logging...
  • Page 13 Performing Interval Logging START Logger Press to start interval log mode. Press to enter data log menu. Subsequent readings are automatically recorded into the multimeter’s memory at the interval specified in the setup menu. Log Counts : 1 A> U1117A-57AE5B STOP STOP Press to exit interval log mode. Typical interval log display.
  • Page 14 Table 4 Datalogger Setup options Option Available settings Description Interval 1 s-10 mins Delay time between subsequent readings. By default it is set at 2 s. Count Mode On/Off (default) Enable or disable the interval data log process to stop when the logged data have reached count settings. Count 1 - 60 000 Total readings that need to be logged. Changing Datalogger Setup Options MENU Logger Press to enter data log mode.
  • Page 15 Reviewing Previously Recorded Data DATA Logger Press to enter data log mode. Press to enter data menu. 01:01 Interval Log (1/2) 25 Jan 2013 00:54:05 AM ( 4 pts) Interval Manual 25 Jan 2013 00:54:35 AM ( 4 pts) Back View Erase All Press to view the interval or manual...
  • Page 16 4 Select U1115A-XXXXXX and click Next. 5 Type the default Bluetooth pairing code “1234” (default) and click Next. 6 Once pairing is successful, a notification window will appear. Click Close. 7 The U1115A-XXXXXX is now added and successfully connected to your PC. 8 Then, you can connect the U1115A to the Keysight Handheld Meter Logger software which is available at www.keysight.com/find/hhmeterlogger XXXXXX denotes the U1115A device name and can be obtained from the U1115A System Info (for more information, refer to page 19).
  • Page 17: Changing The Display Settings

    Changing the Display Settings SETTINGS Display Press to enter settings menu. Press to enter display menu. 01:01 A> U1117A-57AE5B B> U1177A-2718DE A> U1117A-57AE5B B> U1177A-2718DE U1273A-MY51430008 U1272A-MY52800017 U1273A-MY51430008 U1272A-MY52800017 C> U1117A-2391BA Not Connected C> U1117A-2391BA Not Connected U1252B-MY51040033 U1252B-MY51040033 Back Backlight(6) Outdoor Indoor...
  • Page 18 Changing the Power Options SETTINGS More Press to enter settings menu. Press to enter next page. 01:01 Power Options Power Auto Dim Enable Auto Dim Timeout (s) 00.30 Auto Off Enable Auto Off Timeout (m) Back Toggle Press to enter Power Options. Typical Power Options display. • Enable or disable (default) auto dim by toggling the check box next to Press to navigate to...
  • Page 19: Changing The Date And Time

    Changing the Date and Time SETTINGS More System Date/Time 01:01 Date/Time Edit Date 21 June 2013 Time 00:29:24 Back Edit Press to navigate Press to edit the Typical Date/Time display. to desired function. selected values. Resetting the U1115A SETTINGS More System Reset 01:01 System Reset Factory reset will erase all your...
  • Page 20: Enabling/Disabling The Beeper

    Viewing the System Info SETTINGS More System Sys Info 01:01 System Info Model U1115A Serial MY51080009 Typical System Info display. Fw version 01.00 Device Name U1115A-6A1F81 Back Enabling/Disabling the Beeper SETTINGS More Utility 01:01 Utility Beeper Toggle Back Toggle Toggle the check box to enable or Typical Utility display.
  • Page 21 THIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK...
  • Page 22 THIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK...
  • Page 23 THIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK...
  • Page 24 Assistance For technical assistance, contact your nearest Keysight Sales Office or visit the Keysight website at www.keysight.com/find/assist for further information. Modelo U1115A 1851-14-7510 (01) 07898956006039 “Este equipamento opera em caráter U1115-90103 secundário, isto é, não tem direito a proteção ©Keysight Technologies 2014 contra interferência prejudicial, mesmo de Printed in Malaysia estações do mesmo tipo, e não pode causar November 2014 interferência a sistemas operando em caráter...