Keysight U1115A Operating Instructions Manual
Keysight U1115A Operating Instructions Manual

Keysight U1115A Operating Instructions Manual

Remote logging display
Hide thumbs Also See for U1115A:

Advertisement

Quick Links

Keysight U1115A Remote Logging Display

Operating Instructions

The Keysight U1115A Remote Logging display is designed to be used with the
Keysight U1200 Series handheld meters, Keysight U1117A IR-to-Bluetooth
Adapter, Keysight U1177A IR-to-Bluetooth Adapter and mobile/software
applications to provide you a total wireless remote connectivity solution.
With the U1115A, you can view readings from up to four handheld meters
simultaneously, from an extended distance of up to 100-metres (U1117A) within
the line-of-sight.
Keysight U1200
Series handheld
meters
Figure 1 Keysight wireless remote connectivity solution
Standard Shipped Items Checklist
The following items are included with your purchase:
U1115A Remote Logging Display.
Three 1.5 V AA batteries.
USB to micro USB cable (for external power only).
Operating Instructions (this booklet).
Soft Carrying Case.
The Bluetooth
word mark and logos are registered trademark owned by Bluetooth SIG, Inc and any
1
®
use of such marks by Keysight is under license. Other trademark and trade names are those of their
respective owners.
The Keysight U1115A only supports Keysight Handheld Meter Logger software for downloading logged data
2
to PC via a Bluetooth connection.
U1117A IR-to-
Bluetooth adapter
U1177A IR-to-
Bluetooth adapter
U1115A remote
logging display
Windows PC
Android devices
iOS devices
1
2
Keysight PC Application Software
Keysight Handheld Meter
Logger
Keysight Mobile Application
Keysight Mobile Meter
Keysight Mobile Logger
®1
2
2

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the U1115A and is the answer not in the manual?

Questions and answers

Summary of Contents for Keysight U1115A

  • Page 1: Operating Instructions

    Bluetooth SIG, Inc and any ® use of such marks by Keysight is under license. Other trademark and trade names are those of their respective owners. The Keysight U1115A only supports Keysight Handheld Meter Logger software for downloading logged data...
  • Page 2: Product Characteristics

    Bluetooth Bluetooth SPP profile, Class 1 device Compatibility Keysight Handheld Meter/Display: • Keysight U1200 Series Handheld Meters • Keysight U1117A IR-to-Bluetooth Adapter • Keysight U1177A IR-to-Bluetooth Adapter Keysight Application Software: • Keysight Handheld Meter Logger Hardware Device: • Windows PC (with Bluetooth-enabled) Regulatory The U1115A complies with the requirements of the following product standards: • EMC EN 301 489–1:V1.9.2 EN 301 489–17:V2.1.1 EN 55022:2006+A1:2007+A2:2010 (Group 1 Class A) EN 55024:1998+A1:2001+A2:2003 +A3:2010 • RF (Bluetooth) EN 300 328 V1.7.1 (2006–10) • RF (Health) EN 62311:2008...
  • Page 3 Regulatory • Safety EN 60950–1:2006+A11:2009 +A1:2010+A12:2011 “This telecommunication equipment conforms to the NTC technical requirement” Table 1 Connectivity distance (approximate) within the line-of-sight U1177A U1117A U1115A U1177A – – 10 m U1117A – – 100 m U1115A 10 m 100 m – Other Class 1 devices 10 m 100 m...
  • Page 4: Front View

    Front View Sampling annunciator Time indicator 01:01 Battery indicator HOLD MODE CONNECT SETTINGS Function keys Logger key Navigation keys Logger Meter Meter key Figure 2 Front view of the U1115A Remote Logging Display Side View Slide power switch Stand External power port (micro USB port) Figure 3 Side view of the U1115A Remote Logging Display (standing position)
  • Page 5: Back View

    Figure 4 Back view of the U1115A Remote Logging Display Turning On the U1115A To turn on the U1115A , set the slide power switch to On. (as shown in figure 4) • Once a connected IR-to-Bluetooth Adapter is turned off, below scenarios will occur : 1 The Not Connected annunciator will appear on the display.
  • Page 6: Installing And Replacing The Batteries

    Installing and Replacing the Batteries Make sure you turn off the U1115A before installing or replacing the batteries. To avoid the U1115A being damaged from battery leakage: • Always remove dead batteries immediately. • Always remove the batteries and store them separately if the U1115A is not going to be used for a long period of time. Remove the battery protective sheet before using for the first time.
  • Page 7: Connecting To Devices

    Connecting to Devices Ensure that the Link LED at the IR-to-Bluetooth adapter CONNECT is blinking before establishing a connection. Power cycle if necessary. Press to enter Connection Front view of the U1117A Manager. (U1115A) IR-to-Bluetooth adapter 01:01 Connection Manager Enter Scan A> Add Device B> Add Device C> Add Device D> Add Device Back Bluetooth Enter Press to scan for Press to add devices.
  • Page 8 Connect to make a connection. • Select Cancel to cancel a connection. Press to navigate to desired • Select Pairing PIN : 1234 to change PIN number. Ensure that the U1115A function. and the IR-to-Bluetooth adapter(s) have matching PIN number(s). • Select Connect at Startup to set the device to connect on startup. By selecting this option, it will determine the number of views as shown in Table 2 below.
  • Page 9: Meter View

    U1115A. U1115A. ----- The U1115A screen display will show when: 1 No meter is connected. 2 Meter(s) function/mode is not supported by the U1115A. 3 When the user changes the meter’s function. Typical wait time is 5s.
  • Page 10: Selecting Measurement Mode

    Identifying a Connected Meter The identify meter function allows you to easily identify your connected meter(s). To identify the connected meter, follow the steps below : 1 In the meter view, select the desired meter and press CONNECT. 2 Then, navigate to the desired connected device and press Identify. 3 The meter corresponds to the selected device will beep and flash it’s backlight.
  • Page 11 60 000 pts/100 sessions For interval log, a maximum of 60 000 points or 100 sessions can be stored, whichever occurs first. Session ends when the U1115A powers off, count mode ends, restarts new logging or all connected meter(s) disconnect Performing Manual Logging...
  • Page 12 Performing Interval Logging START Logger Press to start interval log mode. Press to enter data log menu. Subsequent readings are automatically recorded into the multimeter’s memory at the interval specified in the setup menu. Log Counts : 1 A> U1117A-57AE5B STOP STOP Press to exit interval log mode. Typical interval log display.
  • Page 13 Table 4 Datalogger Setup options Option Available settings Description Interval 1 s-10 mins Delay time between subsequent readings. By default it is set at 2 s. Count Mode On/Off (default) Enable or disable the interval data log process to stop when the logged data have reached count settings. Count 1 - 60 000 Total readings that need to be logged. Changing Datalogger Setup Options MENU Logger Press to enter data log mode.
  • Page 14 Reviewing Previously Recorded Data DATA Logger Press to enter data log mode. Press to enter data menu. 01:01 Interval Log (1/2) 25 Jan 2013 00:54:05 AM ( 4 pts) Interval Manual 25 Jan 2013 00:54:35 AM ( 4 pts) Back View Erase All Press to view the interval or manual...
  • Page 15 4 Select U1115A-XXXXXX and click Next. 5 Type the default Bluetooth pairing code “1234” (default) and click Next. 6 Once pairing is successful, a notification window will appear. Click Close. 7 The U1115A-XXXXXX is now added and successfully connected to your PC. 8 Then, you can connect the U1115A to the Keysight Handheld Meter Logger software which is available at www.keysight.com/find/hhmeterlogger XXXXXX denotes the U1115A device name and can be obtained from the U1115A System Info (for more information, refer to page 19).
  • Page 16: Changing The Display Settings

    Changing the Display Settings SETTINGS Display Press to enter settings menu. Press to enter display menu. 01:01 A> U1117A-57AE5B B> U1177A-2718DE A> U1117A-57AE5B B> U1177A-2718DE U1273A-MY51430008 U1272A-MY52800017 U1273A-MY51430008 U1272A-MY52800017 C> U1117A-2391BA Not Connected C> U1117A-2391BA Not Connected U1252B-MY51040033 U1252B-MY51040033 Back Backlight(6) Outdoor Indoor...
  • Page 17 Changing the Power Options SETTINGS More Press to enter settings menu. Press to enter next page. 01:01 Power Options Power Auto Dim Enable Auto Dim Timeout (s) 00.30 Auto Off Enable Auto Off Timeout (m) Back Toggle Press to enter Power Options. Typical Power Options display. • Enable or disable (default) auto dim by toggling the check box next to Press to navigate to...
  • Page 18: Changing The Date And Time

    System Reset 01:01 System Reset Factory reset will erase all your data and settings to restore the U1115A back to factory stage. Do you want to proceed? Press to restore Press to cancel. the U1115A to Typical System Reset display.
  • Page 19: Enabling/Disabling The Beeper

    Viewing the System Info SETTINGS More System Sys Info 01:01 System Info Model U1115A Serial MY51080009 Typical System Info display. Fw version 01.00 Device Name U1115A-6A1F81 Back Enabling/Disabling the Beeper SETTINGS More Utility 01:01 Utility Beeper Toggle Back Toggle Toggle the check box to enable or Typical Utility display.
  • Page 20 Assistance For technical assistance, contact your nearest Keysight Sales Office or visit the Keysight Web site at www.keysight.com/find/assist for further information. ©Keysight Technologies, Inc., 2014 Printed in Malaysia April 3, 2014...

Table of Contents