WAC Lighting EN-1260-RB2 Instructions Manual

Class ii electronic transformer

Advertisement

Quick Links

INSTRUCTIONS
CAUTION – TO REDUCE RISK OF FIRE AND ELECTRICAL SHOCK
Always turn off power at main switch prior to installation.
Intended for installation by a qualified electrician.
System is intended for installation in accordance with National Electric Code, and local
regulations. Consult with local inspector to assure compliance.
MAX LOAD
MIN LOAD
INPUT VOLTAGE
INPUT CURRENT
OUTPUT VOLTAGE
CASE TEMP
AMBIENT TEMP
FEATURES:
Electronic short circuit protection with auto-reset.
Overload protection with auto-reset.
Automatic thermal regulation.
Soft start delay to preserve bulb life, for use with tungsten filament lamps.
INSTALLATION
1. Use a minimum of #18 AWG for the output wire.
2. Transformers must be installed away from heat sources and accessible for service.
3. Note: Enclosed transformer is UL listed. The transformer box has a separate line volt,
and low volt wiring compartments. Trade size knock out are provided on both
compartments. Connect building wires to like color transformer wires with wire nuts.
Building ground wire may be green or un-insulated, and attaches to green wire from
transformer box.
4.
Connect out put wires from transformer to fixture wires with wire nuts. Where multiple
fixtures are involved several fixtures wires can be joined by use of the same wire nut.
Wires to fixtures may be chain wired or " home run" wired back to the transformer. High
frequency output is only readable with a true RMS meter, with sufficient range capability.
WIRE SIZE
18 GAUGE
16 GAUGE
14 GAUGE
12 GAUGE
Class II Electronic Transformer
Model EN-1260-RB2
MAXIMUM LENGTH / VOLTAGE DROP GUIDELINE
35 WATT
10 FT
14 FT
21 FT
28 FT
60W
20W
120V
0.53A
11.6V
90ºC (194°F)
-20ºC TO 50ºC (-4°F TO 122°F)
50 WATT
9 FT
13 FT
19 FT
25 FT
Retain these instructions for future service and adjustments
615 South Street, Garden City, NY 11530
Tel: (516) 515-5000 Fax (516) 515-5050
60 WATT
8 FT
11 FT
15 FT
21 FT
www.waclighting.com

Advertisement

loading
Need help?

Need help?

Do you have a question about the EN-1260-RB2 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for WAC Lighting EN-1260-RB2

  • Page 1 INSTRUCTIONS Class II Electronic Transformer Model EN-1260-RB2 CAUTION – TO REDUCE RISK OF FIRE AND ELECTRICAL SHOCK • Always turn off power at main switch prior to installation. • Intended for installation by a qualified electrician. • System is intended for installation in accordance with National Electric Code, and local regulations.
  • Page 2: Installation

    INSTRUCTIONS Class II Electronic Transformer Model : EN-1260-RB2-N CAUTION – TO REDUCE RISK OF FIRE AND ELECTRICAL SHOCK • Always turn off power at main switch prior to installation. • Intended for installation by a qualified electrician. • System is intended for installation in accordance with National Electric Code, and local regulations.
  • Page 3 INSTRUCTIONS Class 2 Electronic Transformer Model : EN-12180-RB2 CAUTION – TO REDUCE RISK OF FIRE AND ELECTRICAL SHOCK  Always turn off power at main switch prior to installation.  Intended for installation by a qualified electrician.  System is intended for installation in accordance with National Electric Code, and local regulations. Consult with local inspector to assure compliance.
  • Page 4: Mounting Instruction

    MOUNTING INSTRUCTION: T O SEPARAT E INST ALLAT ION WIRES OUTPUT (12-18AWG) EN-12180-RB2 WHIT E WIRE BLACK WIRE INPUT GREEN OUTPUT (GND) 120VAC SWIT CH 12V AC 20KHz Per Circuit 60Hz WIRES INPUT-18AWG GREEN WHITE (Neutral Wire) BLACK (Hot Wire) Min 1 ×...
  • Page 5 INSTRUCTIONS Class2 Electronic Transformer Model : EN-12300-RB2 CAUTION – TO REDUCE RISK OF FIRE AND ELECTRICAL SHOCK  Always turn off power at main switch prior to installation.  Intended for installation by a qualified electrician.  System is intended for installation in accordance with National Electric Code, and local regulations. Consult with local inspector to assure compliance.
  • Page 6 MOUNTING INSTRUCTION WIRES OUTPUT (12-18AWG) INPUT 120VAC 60Hz GREEN TO SEPARATE GREEN (GND) INSTALLATION WIRES INPUT-18AWG EN-12300-RB2 (Hot Wire) BLACK WHITE (Neutral Wire) OUTPUT 12V AC 20KHz Per Circuit Min 1 × 20W Lamp Max 3 × 20W Lamps Retain these instructions for future service and adjustments 615 South Street, Garden City, NY 11530 Tel: (516) 515-5000 Fax (516) 515-5050 www.waclighting.com...

This manual is also suitable for:

En-1260-rb2-nEn-12180-rb2