INSTRUCTIONS
CAUTION – TO REDUCE RISK OF FIRE AND ELECTRICAL SHOCK
•
Always turn off power at main switch prior to installation.
•
Intended for installation by a qualified electrician.
•
System is intended for installation in accordance with National Electric Code, and local
regulations. Consult with local inspector to assure compliance.
MAX LOAD
MIN LOAD
INPUT VOLTAGE
INPUT CURRENT
OUTPUT VOLTAGE
MAX CASE TEMP
AMBIENT TEMP
FEATURES:
•
Electronic short circuit protection with auto reset.
•
Overload protection with auto reset.
•
Automatic thermal regulation.
•
Soft start delay to preserve bulb life, for use with tungsten filament lamps.
•
Dimmable with electronic dimmer switches.
INSTALLATION:
1. For the EN-1260-R-AR model, use a minimum of #18 AWG for the output wire.
2. For the EN-1275-R-AR model, use a minimum of #16 AWG for the output wire.
3. Transformers must be installed away from heat sources and accessible for service.
4. Note: Enclosed transformer is UL listed. The transformer box has a separate line volt, and low
volt wiring compartments. Trade size knock out are provided on both compartments. Connect
building wires to like color transformer wires with wire nuts. Building ground wire may be green
or un-insulated, and attaches to green wire from transformer box.
5. Connect out put wires from transformer to fixture wires with wire nuts. Where multiple fixtures
are involved several fixtures wires can be joined by use of the same wire nut. Wires to fixtures
may be chain wired or " home run" wired back to the transformer. High frequency output is only
readable with a true RMS meter, with sufficient range capability.
6. Low volt wiring concealed in walls and ceilings requires enclosed and clamped connections.
WIRE SIZE
35 W
18 GAUGE
10 FT
16 GAUGE
14 FT
14 GAUGE
21 FT
12 GAUGE
28 FT
:
Model: EN-1260-RB-AR and EN-1275-RB-AR
60/75 Watt 12 Volt Electronic Transformers
EN-1260-RB-AR
60W
20W
120V
0.53A
11.6V
MAXIMUM LENGTH / VOLTAGE DROP GUIDELINE
50 W
9 FT
13 FT
19 FT
25 FT
90º C (194ºF)
-20º C ~ +50º C (-4ºF ~ 122ºF)
60 W
8 FT
11 FT
15 FT
21 FT
Retain these instructions for future service and adjustments
EN-1275-RB-AR
75W
20W
120V
0.63A
11.6V
75W
7FT
10FT
14FT
20FT
615 South Street, Garden City, NY 11530
Tel: (516) 515-5000 Fax (516) 515-5050
www.waclighting.com
Need help?
Do you have a question about the EN-1260-RB-AR and is the answer not in the manual?
Questions and answers