COMPONENTS IN LIFE SUPPORT DEVICES OR SYSTEMS. Products sold by United Electronic Industries, Inc. are not authorized for use as critical components in life support devices or systems. A critical component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness.
Chapter 1 Introduction Chapter 1 Introduction This document outlines the feature set and use of the DNx-AO-308-352, an 8- channel, medium voltage analog output board. This following product versions are described in this manual: • DNx-AO-308-352 16-bit, 8-channel, ±13.5V Analog Output Layer...
±13.5V Analog Output Board only. The other products in the series are described in separate documents. Using a DNx-AO-308-352 instead of a DNx-AO-308 boosts voltage capability to ±13.5V per channel and current output up to ±13.5mA per channel. The technical specifications for the DNx-AO-308-352 Medium Voltage Analog Output Board are listed in Table 1-1.
Reference Figure 1-2. Block Diagram of DNA-AO-308-352 Device Architecture Layer Since the DNx-AO-308-352 board is designed with output buffers, separate sense lines are not provided. To minimize error due to differences in lead Connectors resistance, be sure to use equal length signal and return lines.