Page 3
Microsoft® Corporation. ® LATS Revit integrates the LG LATS program with Revit® software**. It permits engineers to layout and validate LG VRF, Multi F / Multi F MAX, Single-Zone, and DOAS directly into Revit drawings.
R32 Refrigerant LG Electronic split system heating and air conditioning (HVAC) products now contain R32 refrigerant. While R32 refrigerant is slightly flammable, it has a higher efficiency, a lower Global Warming Potential (GWP) value, and is more environmentally friendly than R410A.
PRODUCT DATA Nomenclature on page 8 Pairing Table on Page 9 Mechanical Specifications on page 10 General Data on page 12 Electrical Data on page 14 Functions, Controls, and Options on page 15 Accessories on page 16 Outdoor Unit Dimensions on page 19 Outdoor Unit Center of Gravity / Corner Weight on page 20 Indoor Unit Dimensions on page 21 Air Flow, Temperature Distribution Graphs on page 22...
Page 17
ACCESSORIES LG Monitoring View (LGMV) Diagnostic Software and Cable LG Monitoring View (LGMV) is a maintenance and troubleshooting tool for Multi V™ air conditioning systems. LGMV formats are available for computer or mobile phone use. The main screen for LGMV allows the user to view the following real time data: •...
PERFORMANCE DATA Cooling Capacity on page 27 Maximum Cooling Capacity on page 29 Heating Capacity on page 31 Maximum Heating Capacity on page 33 Correction Factors on page 35 Check Selection on page 36...
• Use caution when sizing to meet listed capacity specifications for the scheduled manufacturer’s equipment. If further system design assistance is needed, or you have a unique application you would like to discuss, contact an LG sales rep. Due to our policy of continuous product innovation, some specifications may change without notification.
APPLICATION GUIDELINES Placement / Clearance Considerations for Indoor Units on page 38 Placement / Clearance Considerations for Outdoor Units on page 40 Installing Outdoor Units Indoors on page 44...
REFRIGERANT PIPING DESIGN Refrigerant Flow Diagrams on page 48 Connection Limitations and System Layout on page 50 Additional Refrigerant Charge on page 51 Refrigerant Piping System Engineering on page 52...
KUSXB091A, KUSXB121A Outdoor Units Various tools are available to assist in properly designing LG R32 split systems. Refer to the “R32 Application Guide”; the “Simple Calculator for Ca- pacity, Refrigerant Charge and ESP”; the “LG Air Conditioner Technical Solutions” (LATS) software program; and the local LG Sales Representative.
Page 49
KNUQB091A, KNUQB121A Indoor Units Various tools are available to assist in properly designing LG R32 split systems. Refer to the “R32 Application Guide”; the “Simple Calculator for Ca- pacity, Refrigerant Charge and ESP”; the “LG Air Conditioner Technical Solutions” (LATS) software program; and the local LG Sales Representative.
CONNECTION LIMITATIONS / SYSTEM LAYOUT Various tools are available to assist in properly designing LG R32 split systems. Refer to the “R32 Application Guide”; the “Simple Calculator for Ca- pacity, Refrigerant Charge and ESP”; the “LG Air Conditioner Technical Solutions” (LATS) software program; and the local LG Sales Representative.
ADDITIONAL REFRIGERANT CHARGE Various tools are available to assist in properly designing LG R32 split systems. Refer to the “R32 Application Guide”; the “Simple Calculator for Ca- pacity, Refrigerant Charge and ESP”; the “LG Air Conditioner Technical Solutions” (LATS) software program; and the local LG Sales Representative.
REFRIGERANT PIPING SYSTEM ENGINEERING Various tools are available to assist in properly designing LG R32 split systems. Refer to the “R32 Application Guide”; the “Simple Calculator for Ca- pacity, Refrigerant Charge and ESP”; the “LG Air Conditioner Technical Solutions” (LATS) software program; and the local LG Sales Representative.
REFRIGERANT PIPING SYSTEM ENGINEERING Various tools are available to assist in properly designing LG R32 split systems. Refer to the “R32 Application Guide”; the “Simple Calculator for Ca- pacity, Refrigerant Charge and ESP”; the “LG Air Conditioner Technical Solutions” (LATS) software program; and the local LG Sales Representative.
Page 54
REFRIGERANT PIPING SYSTEM ENGINEERING Various tools are available to assist in properly designing LG R32 split systems. Refer to the “R32 Application Guide”; the “Simple Calculator for Ca- pacity, Refrigerant Charge and ESP”; the “LG Air Conditioner Technical Solutions” (LATS) software program; and the local LG Sales Representative.
Page 55
REFRIGERANT PIPING SYSTEM ENGINEERING Various tools are available to assist in properly designing LG R32 split systems. Refer to the “R32 Application Guide”; the “Simple Calculator for Ca- pacity, Refrigerant Charge and ESP”; the “LG Air Conditioner Technical Solutions” (LATS) software program; and the local LG Sales Representative.
REFRIGERANT PIPING SYSTEM ENGINEERING Various tools are available to assist in properly designing LG R32 split systems. Refer to the “R32 Application Guide”; the “Simple Calculator for Ca- pacity, Refrigerant Charge and ESP”; the “LG Air Conditioner Technical Solutions” (LATS) software program; and the local LG Sales Representative.
REFRIGERANT PIPING SYSTEM ENGINEERING Various tools are available to assist in properly designing LG R32 split systems. Refer to the “R32 Application Guide”; the “Simple Calculator for Ca- pacity, Refrigerant Charge and ESP”; the “LG Air Conditioner Technical Solutions” (LATS) software program; and the local LG Sales Representative.
ELECTRICAL General Guidelines on page 59 Wiring Diagrams on page 60 Power Supply / Power Wiring on page 64 Communication / Connection Cable on page 65 Controllers on page 67...
Optional controllers (see “Functions, Controls, Options”, or contact an LG representative for more information) can connect to the indoor unit in one of two different ways. • LG Wired Remote Extension Cable with Molex plug (PZCWRC1; sold separately) that connects to the CN-REMO terminal on the indoor unit PCB.
Page 70
LG Electronics, U.S.A., Inc. Air Conditioning Technologies EM_SZ_Console_R32_01_25 4300 North Point Parkway Supersedes: EM_SZ_Console_R32_11_24 Alpharetta, Georgia 30022 www.lghvac.com...