SMOKE ALARM R10RF
Photoelectric Smoke Alarm with 10 Year Lithium Battery & Wireless Connection
INSTALLATION INSTRUCTIONS
PLEASE NOTE: READ ALL INSTRUCTIONS BEFORE INSTALLATION. NO USER SERVICEABLE PARTS INSIDE THIS SMOKE ALARM.
IMPORTANT: This manual contains important information about the installation and operation of your smoke alarm. Please read carefully before
installation and keep for future reference. Please ensure that this leaflet remains in the household where the alarm is installed.
WARNING: This smoke alarm is designed to alert you to the presence of
not be effective such as smoking in bed, explosions, etc. The ultimate responsibility for fire protection rests with you, this responsibility includes escape
planning, safety checks and an effective warning system. In case of fire, a well-placed, properly looked after smoke alarm may provide a few seconds
so that you can escape and call the fire brigade.
IMPORTANT SAFETY INFORMATION
1. The battery must be operational to operate the alarm
correctly. To test the
battery,
this smoke alarm.
2. The test button sufficiently tests all smoke alarm
functions. DO NOT use any other test method.
3. DO NOT remove or disconnect alarm to silence
unwanted sounding, this will remove your protection.
Press the hush button or open windows to ventilate
the smoke alarm to silence it.
4. This smoke alarm is designed to be used inside a single
dwelling only. In buildings with several
dwellings/units, each individual living unit should
have their own smoke alarms.
on every level of the home.
5. Install a smoke alarm
6. Smoke alarms can only sound their alarms when they
detect smoke or detect combustion particles in the
air, they do not sense heat, flame, or gas.
This smoke alarm is designed to give an audible
warning of a developing fire, however, many fires are
fast burning, explosive or intentional. Others are
caused by careless-ness or safety hazards. Smoke may
not reach the smoke alarm quickly enough to ensure
safe escape.
7 Smoke alarms have limitations. This smoke alarm is
not foolproof and is not warranted to protect lives or
property from fire. Smoke alarms are not a substitute
for insurance. Homeowners and renters should
insure
their lives and property. In addition, it is possible
smoke alarm to fail at any time. For this
for the
reason, you must test the smoke alarm weekly and
replace every 10 years.
Locating and Positioning of Smoke Alarms:
If your dwelling is on a single storey, for minimum protection you should fit an alarm in the hallway
between the living areas (incl. Kitchens) and sleeping areas. Place it as near to the living areas as
possible and ensure the alarm is audible when the bedrooms are occupied.
If your dwelling is multi-storey, for minimum protection one alarm should be fitted at the bottom of
the staircase with further alarms fitted on each upstairs landing. This includes basements but
excludes crawl spaces and unfinished attics.
NOTE: For maximum
protection,
an alarm should be fitted in every room (except kitchen, bathroom and garage).
DO NOT FIT AN ALARM IN THE KITCHEN or BATHROOM, as cooking fumes or steam may trigger the alarm.
DO NOT FIT ALARM IN A GARAGE, as exhaust fumes are likely to set it off.
Ceiling Mounting
As hot smoke rises and spread out, it is advisable to mount on a ceiling in a central position. Avoid areas
where there is no air circulation. E.g., Corners of rooms and keep away from items which may prevent the
free flow of air. Place the unit at least 300mm from any light fitting or decorative object which might
obstruct smoke / heat entering the alarm. Keep at least 300mm away from walls. See Figure 3i.
Wall Mounting
Do not mount tight into corners, place the top edge of your smoke alarm 500mm below the ceiling.
Keep at least 300mm from room corners. See Figure 3i
On a Sloping Ceiling
In areas with sloping or peaked ceilings install your Smoke Alarm 900mm from the highest point measured
horizontally because "dead air" at the apex may prevent smoke from reaching the unit. See Figure 3ii.
Specifications:
Main Power Source
Lithium 10 Year 3V Sealed-Battery
Type A Photoelectric smoke alarm
Sensing Type
- contains NO radioactive material
Sensitivity to smoke
0.08-0.2db/m
Operation Current
<20mA operation (In Alarm)
Temperature Range
0°C to 45°C
Humidity Range
0% to 95% RH
Interconnecting RF
40 alarms for wireless interconnection
Range
100m free air
30m indoors (line of sight)
Pairing duration
2 min (recount after each success pairing)
Sound Level
85dB at three metres minimum
Alarm Condition
Audible signal pattern (ISO 8201)
Visual Indicators
Red LED for warning and low battery
Approval
AS 3786:2014, UL S36341
Installation of Smoke Alarms:
press the test button on
1. From back of the smoke alarm, remove the
2. Position smoke alarm mounting plate on wall or
3. Mount alarm head to base and turn clockwise to
WARNING:
decrease in operational effectiveness.
Wireless Connection Setup Guide:
1. Connect all alarm bases to alarms heads and turn clockwise to engage 'on' switch.
2. Select one of the alarms as the MASTER. Place the MASTER label on the exterior edge of the alarm so it can be
3. On the rear side of MASTER alarm head, press and hold the wireless pairing button for at least 5 seconds until led
4. While the MASTER unit's LED is on, press the wireless pairing button 2 times on a BRANCH wireless alarm. The
NOTE: If the BRANCH units do not flash their LED 5 times, the wireless interconnection has failed, in this case, check
that the alarm is in 'on' mode with the base properly engaged clockwise and that the master is still in self pairing
mode. If needing to put the master back into self-pairingmode, you will only need to pair branch units that were not
paired previously.
5. Repeat step 3 and 4 on all other BRANCH alarms within the 30 second window.
6. After pairing all unit, press and hold MASTER alarm's Test/Hush button to for up to 15 seconds to check that all
7. Once all alarms are paired, remove the base by turning anti-clockwise to switch off. Proceed installation to
smoke,
it cannot prevent a fire. There are hazards which smoke alarms may
mounting plate by turning it counter clockwise.
ceiling and screw into place.
engage 'on' function. Push test button to test
smoke alarm.
Incorrect orientation will result in a
identified in the future. Treat all other alarms as BRANCH units.
on front illuminates. The unit is now in self-learn pairing mode indicated by the LED on the front of alarm remaining
on for a 30 second window.
NOTE: To exit self-learn pairing mode, press the wireless pairing button one time. The Red LED will turn off.
branch alarm LED will flash 5 times indicating successful interconnection.
interconnected units receive the RF signal and alarms sound.
ceiling/wall.
SMOKE ALARMS
Features:
• DC operated photoelectric type smoke alarm
• Photoelectric sensor for slow smouldering fires
• Wireless Interconnection
• Insect proof
• Test & Hush button
• Environmentally friendly non-radioactive
technology High and stable sensitivity
• Quick fix mounting bracket for easy installation
• Fitting and battery tamper-resist feature
LED operation indicator
• Extra loud alarm sound over 85 dB
• Low-battery and battery missing
warning indicators
• Auto reset when smoke clears
Mounting Plate
Alarm Unit
Turn counter clockwise
to uninstall
CEILING / WALL JUNCTION
APEX OF
SLOPING
CEILING
DEAD
HEAT &
AIR SPACE
SMOKE
FROM
FIRE
BEST
BEST
HERE
HERE
HEAT & SMOKE
FROM FIRE
SINGLE-STOREY RESIDENCE, APARTMENT, MOBILE HOME
BEDROOM
W/C
BATH
LOUNGE ROOM
BEDROOM
BEDROOM
KITCHEN
DINING
Smoke alarms for minimum protection.
Smoke alarms for additional protection.
Turn clockwise
to install
300mm min
CEILING
DEAD AIR
SPACE
BEST
NEVER
HERE
HERE
ACCEPTABLE HERE
SIDE WALL
MULTI-STOREY RESIDENCE
BED
BED
HALL
ROOM
ROOM
KITCHEN
LIVING
ROOM
BASEMENT
Smoke alarms with hush features
recommended for additional
protection
Need help?
Do you have a question about the R10RFB and is the answer not in the manual?
Questions and answers