SMOKE ALARM R10RF
Photoelectric Smoke Alarm with 10 Year Lithium Battery & Wireless Connection
INSTALLATION INSTRUCTIONS
PLEASE NOTE: READ ALL INSTRUCTIONS BEFORE INSTALLATION. NO USER SERVICEABLE PARTS INSIDE THIS SMOKE ALARM.
IMPORTANT: This manual contains important information about the installation and operation of your smoke alarm. Please read carefully before
installation and keep for future reference. Please ensure that this leaflet remains in the household where the alarm is installed.
WARNING: This smoke alarm is designed to alert you to the presence of
not be effective such as smoking in bed, explosions, etc. The ultimate responsibility for fire protection rests with you, this responsibility includes escape
planning, safety checks and an effective warning system. In case of fire, a well-placed, properly looked after smoke alarm may provide a few seconds
so that you can escape and call the fire brigade.
IMPORTANT SAFETY INFORMATION
1. The battery must be operational to operate the alarm
correctly. To test the battery,press the test button on this
smoke alarm.
2. The test button sufficiently tests all smoke alarm
functions. DO NOT use any other test method.
3. DO NOT remove or disconnect alarm to silence
unwanted sounding, this will remove your protection.
Press the hush button or open windows to ventilate the
smoke alarm to silence it.
4. This smoke alarm is designed to be used inside a single
dwelling only. In buildings with several dwellings/units,
each individual living unit should have their own smoke
alarms.
5. Install a smoke alarm on every level of the home.
6. Smoke alarms can only sound their alarms when they
detect smoke or detect combustion particles in the air,
they do not sense heat, flame, or gas. This smoke alarm
is designed to give an audible warning of a developing
fire, however, many fires are fast burning, explosive or
intentional. Others are caused by carelessness or safety
hazards. Smoke may not reach the smoke alarm quickly
enough to ensure safe escape.
7. Smoke alarms have limitations. This smoke alarm is not
fool proof and is not warranted to protect lives or property
from fire. Smoke alarms are not a substitute for
insurance. Homeowners and renters should insure their
lives and property. In addition, it is possible for the smoke
alarm to fail at any time. For this reason, you must test
the smoke alarm weekly and replace every 10 years.
Locating and Positioning of Smoke Alarms:
If your dwelling is on a single storey, for minimum protection you should fit an alarm in the hallway
between the living areas (incl. kitchens) and sleeping areas. Place it as near to the living areas as
possible and ensure the alarm is audible when the bedrooms are occupied.
If your dwelling is multi-storey, for minimum protection one alarm should be fitted at the bottom of the
staircase with further alarms fitted on each upstairs landing. This includes basements but excludes crawl
spaces and unfinished attics.
NOTE: For maximum protection, an alarm should be fitted in every room (except kitchen, bathroom and garage).
DO NOT FIT AN ALARM IN THE KITCHEN or BATHROOM, as cooking fumes or steam may trigger the alarm.
DO NOT FIT ALARM IN A GARAGE, as exhaust fumes are likely to set it off.
Ceiling Mounting
As hot smoke rises and spread out, it is advisable to mount on a ceiling in a central position. Avoid areas
where there is no air circulation. E.g.,Corners of rooms and keep away from items which may prevent
the free flow of air. Place the unit at least 300mm from any light fitting or decorative object which might
obstruct smoke / heat entering the alarm. Keep at least 300mm away from walls. See Figure 3i.
Wall Mounting
Do not mount tight into corners, place the top edge of your smoke alarm 500mm below the ceiling. Keep
at least 300mm from room corners. See Figure 3i
On a Sloping Ceiling
In areas with sloping or peaked ceilings install your Smoke Alarm 900mm from the highest point
measured horizontally because "dead air" at the apex may prevent smoke from reaching the unit. See
Figure 3ii.
Specifications:
Main Power Source
Lithium 10Year 3V Sealed-Battery
Sensing Type
Type A Photoelectric smoke alarm
-contains NO radioactive material
Sensitivity to smoke
0.08-0.2db/m
Operation Current
<20mA operation (In Alarm)
Temperature Range
0°C to 45°C
Humidity Range
5% to 95% RH
Type of Installation
Indoor
Interconnecting RF
40 alarms for wireless interconnection
Range
100m free air
30m indoors (line of sight)
Pairing duration
2 min (recount after each success pairing)
Sound Level
85dB at three metres minimum
Alarm Condition
Audible signal pattern (ISO8201)
Visual Indicators
Red LED for warning and low battery
Approval
AS 3786:2014, UL S36341
Wireless Connection Setup Guide:
1. Connect all alarm bases to alarms heads and turn clockwise to engage 'on' switch.
2. Select one of the alarms as the MASTER. Place the MASTER label on the exterior edge of the alarm so it can be
3. On the rear side of MASTER alarm head, press and hold the wireless pairing button for at least 5 seconds until led
4. While the MASTER unit's LED is on, press the wireless pairing button 2 times on a BRANCH wireless alarm. The
NOTE: If the BRANCH units do not flash their LED 5 times, the
wireless interconnection has failed, in this case, check that the
alarm is in 'on' mode with the base properly engaged clockwise and
that the master is still in self pairing mode. If needing to put the
master back into self-pairingmode, you will only need to pair branch
units that were not paired previously.
5. Repeat step 3 and 4 on all other BRANCH alarms within the 30
6. After pairing all unit, press and hold MASTER alarm's Test/Hush
7. Once all alarms are paired, remove the base by turning
Installation of Smoke Alarms:
1. From back of the smoke alarm, remove the mounting
2. Position smoke alarm mounting plate on wall or ceiling
3. Mount alarm head to base and turn clockwise to engage
smoke,
it cannot prevent a fire. There are hazards which smoke alarms may
identified in the future. Treat all other alarms as BRANCH units.
on front illuminates. The unit is now in self-learn pairing mode indicated by the LED on the front of alarm remaining
on for a 30 second window.
NOTE: To exit self-learn pairing mode, press the wireless pairing button once. The Red LED will turn off.
branch alarm LED will flash 5 times indicating successful interconnection.
second window.
button to for up to 15 seconds to check that all interconnected
units receive the RF signal and alarms sound.
anti-clockwise to switch off. Proceed installation to ceiling/wall.
plate by turning it counter clockwise.
and screw into place.
'on' function. Push test button to test smoke alarm.
WARNING: Incorrect orientation will result in a decrease
in operational effectiveness.
SMOKE ALARMS
Features:
• DC operated photoelectric type smoke alarm
• Photoelectric sensor for slow smouldering fires
• Wireless Interconnection
• Insect proof
• Test & Hush button
• Environmentally friendly non-radioactive technology
• High and stable sensitivity
• Quick fix mounting bracket for easy installation
• Fitting and battery tamper-resistant feature
• LED operation indicator
• Extra loud alarm sound over 85 dB
• Low-battery and battery missing warning indicators
• Auto reset when smoke clears
1. Installed the
mounting plate on
the Alarm Unit first
and activate the
Alarm unit.
2. Flip to the back
side of the Alarm
Unit and find the
RF Pairing Button
Mounting Plate
Alarm Unit
Turn counter clockwise
to uninstall
Figure 3i
CEILING / WALL JUNCTION
300mm min
CEILING
DEAD AIR
HEAT &
SPACE
SMOKE
FROM
FIRE
BEST
NEVER
HERE
HERE
ACCEPTABLE HERE
SIDE WALL
SINGLE-STOREY RESIDENCE, APARTMENT
BEDROOM
W/C
BATH
LOUNGE ROOM
BEDROOM
BEDROOM
KITCHEN
DINING
Smoke alarms for minimum protection.
Smoke alarms for additional protection.
RF Pairing Butotn
Turn clockwise
to install
Figure 3ii
APEX OF
SLOPING
CEILING
DEAD
AIR SPACE
BEST
BEST
HERE
HERE
HEAT & SMOKE
FROM FIRE
MULTI-STOREY RESIDENCE
BED
BED
HALL
ROOM
ROOM
KITCHEN
LIVING
ROOM
BASEMENT
Smoke alarms with hush features
recommended for additional
protection
Need help?
Do you have a question about the R10RF and is the answer not in the manual?
Questions and answers