PG-03 Terminal Descriptions
Terminals
Terminal Symbols
+12V
0V
A/O, B/O
Wiring Notes
1.
Please use a shield cable to prevent interference. Do not run control wire parallel to any high
voltage AC power line (220 V and up).
2.
Connect shielded wire to
3.
Recommended wire size 0.21 to 0.81mm
4.
Wire length:
The Output Types of the
Encoder
Output Voltage
Open Collector
Line Driver
Complementary
Power Supply of the Encoder: +12V
Output Voltage: +12V±5% 200mA
Common point for the power supply and the signal
Encoder signal input (select the output type of the Encoder from FSW2)
Both single-phase input and two-phase input available
Maximum: 500KP/Sec
The Encoder signal output
Maximum: DC24V 50mA
Common point for signal grounding
E only.
Maximum Wire
Length
50m
50m
300m
70m
Descriptions
2
(AWG24 to AWG18).
Wire Gauge
2
1.25mm
(AWG16) or above