ADEO CONTROL SGD-C4-1 Installation And User Manual

Server gateway dmx for control4 integrations

Advertisement

Quick Links

Adeo Control SGD-C4-1
Adeo Group s.r.l.
Via della Zarga n. 50 - 38015 LAVIS (TN)
Manual
Tel: +39 0461 248211 - Fax: +39 0461 245038
Mail: info@adeogroup.it – www.adeogroup.it
Rev. 3
A
C
SGD-C4-1
DEO
ONTROL
S
G
DMX
ERVER
ATEWAY
for Control4 integrations
INSTALLATION AND USER MANUAL
V3
Firmware version: 1.0.34
December 2023
Ad eo C o nt ro l i s a b ra nd o f Ad eo G ro u p s.r .l .
1 / 17

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SGD-C4-1 and is the answer not in the manual?

Questions and answers

Summary of Contents for ADEO CONTROL SGD-C4-1

  • Page 1 Adeo Control SGD-C4-1 Adeo Group s.r.l. Via della Zarga n. 50 - 38015 LAVIS (TN) Manual Tel: +39 0461 248211 - Fax: +39 0461 245038 Mail: info@adeogroup.it – www.adeogroup.it Rev. 3 SGD-C4-1 ONTROL ERVER ATEWAY for Control4 integrations INSTALLATION AND USER MANUAL Firmware version: 1.0.34...
  • Page 2: Table Of Contents

    Adeo Control SGD-C4-1 Adeo Group s.r.l. Via della Zarga n. 50 - 38015 LAVIS (TN) Manual Tel: +39 0461 248211 - Fax: +39 0461 245038 Mail: info@adeogroup.it – www.adeogroup.it Rev. 3 Summary Release Note ........................... 3 Application ............................4 Technical Notes ..........................5 Characteristics ..........................
  • Page 3: Release Note

    Adeo Control SGD-C4-1 Adeo Group s.r.l. Via della Zarga n. 50 - 38015 LAVIS (TN) Manual Tel: +39 0461 248211 - Fax: +39 0461 245038 Mail: info@adeogroup.it – www.adeogroup.it Rev. 3 1. Release Note Dashboard version Firmware version TCP/IP stack version 0.0.81...
  • Page 4: Application

    2. Application The new Adeo Server Gateway SGD-C4-1 is a multi-output device that operates at the network level and allows data packets to be routed to fieldbus communication systems such as DMX512A to provide advanced lighting control. Once the IP address is assigned on the Composer Pro, the SGD-C4-1, through specific drivers, is able to manage the individual channel or RGB through DMX.
  • Page 5: Technical Notes

    Adeo Control SGD-C4-1 Adeo Group s.r.l. Via della Zarga n. 50 - 38015 LAVIS (TN) Manual Tel: +39 0461 248211 - Fax: +39 0461 245038 Mail: info@adeogroup.it – www.adeogroup.it Rev. 3 3. Technical Notes Installation: •Installation and maintenance must only be carried out by qualified personnel in accordance with the regulations in force.
  • Page 6: Characteristics

    Adeo Control SGD-C4-1 Adeo Group s.r.l. Via della Zarga n. 50 - 38015 LAVIS (TN) Manual Tel: +39 0461 248211 - Fax: +39 0461 245038 Mail: info@adeogroup.it – www.adeogroup.it Rev. 3 4. Characteristics Tensione di alimentazione - Supply Voltage 12 / 24 / 48 Vdc or POE...
  • Page 7: Connections

    POWER OVER PASSIVE ETHERNET (POE) The device is also capable of operating on PoE power. The SGD-C4-1 is a passive PD (Passive Power Device) that is powered without negotiation or communication processes from a PoE switch. To enable this power supply, simply move the PoE selector upwards.
  • Page 8: Status Led

    Adeo Control SGD-C4-1 Adeo Group s.r.l. Via della Zarga n. 50 - 38015 LAVIS (TN) Manual Tel: +39 0461 248211 - Fax: +39 0461 245038 Mail: info@adeogroup.it – www.adeogroup.it Rev. 3 7. Status LED LED1(left) LED2 LED3 Function Ethernet BUS1(DMX/RTU)
  • Page 9: Web Server (Ethernet)

    Adeo Control SGD-C4-1 Adeo Group s.r.l. Via della Zarga n. 50 - 38015 LAVIS (TN) Manual Tel: +39 0461 248211 - Fax: +39 0461 245038 Mail: info@adeogroup.it – www.adeogroup.it Rev. 3 9. Web Server (Ethernet) 1. Access your operating system browser (Google Chrome recommended) and access the local gateway address after connecting the Ethernet cable to the local network.
  • Page 10: Configuration Menu

    Adeo Control SGD-C4-1 Adeo Group s.r.l. Via della Zarga n. 50 - 38015 LAVIS (TN) Manual Tel: +39 0461 248211 - Fax: +39 0461 245038 Mail: info@adeogroup.it – www.adeogroup.it Rev. 3 10. Configuration menu Channels: complete list of channels with relative control...
  • Page 11: Channells

    Adeo Control SGD-C4-1 Adeo Group s.r.l. Via della Zarga n. 50 - 38015 LAVIS (TN) Manual Tel: +39 0461 248211 - Fax: +39 0461 245038 Mail: info@adeogroup.it – www.adeogroup.it Rev. 3 11. Channells The gateway has a WebApp to supervise and set up all available channels by choosing from the Channels pop-up menu, which can be used from any recent device with a compatible browser (see below).
  • Page 12: Bus Configuration

    Adeo Control SGD-C4-1 Adeo Group s.r.l. Via della Zarga n. 50 - 38015 LAVIS (TN) Manual Tel: +39 0461 248211 - Fax: +39 0461 245038 Mail: info@adeogroup.it – www.adeogroup.it Rev. 3 12. Bus Configuration Bus 1 and 2 are related to the first and second DMX port.
  • Page 13: Local Inputs Configuration

    Adeo Control SGD-C4-1 Adeo Group s.r.l. Via della Zarga n. 50 - 38015 LAVIS (TN) Manual Tel: +39 0461 248211 - Fax: +39 0461 245038 Mail: info@adeogroup.it – www.adeogroup.it Rev. 3 SETTINGS 13. Local inputs configuration On this page, you can enable or disable the 8 local inputs. By default, local inputs are disabled.
  • Page 14: Network

    Adeo Control SGD-C4-1 Adeo Group s.r.l. Via della Zarga n. 50 - 38015 LAVIS (TN) Manual Tel: +39 0461 248211 - Fax: +39 0461 245038 Mail: info@adeogroup.it – www.adeogroup.it Rev. 3 14. Network The gateway uses the Ethernet port via IPv4 protocol.
  • Page 15: Telnet

    Adeo Control SGD-C4-1 Adeo Group s.r.l. Via della Zarga n. 50 - 38015 LAVIS (TN) Manual Tel: +39 0461 248211 - Fax: +39 0461 245038 Mail: info@adeogroup.it – www.adeogroup.it Rev. 3 16. Telnet The gateway has a Telnet server that can receive and/or transmit a DMX512A universe from/to other devices via TCP protocol, in our case to the Control4 driver.
  • Page 16: Firmware Update

    Adeo Control SGD-C4-1 Adeo Group s.r.l. Via della Zarga n. 50 - 38015 LAVIS (TN) Manual Tel: +39 0461 248211 - Fax: +39 0461 245038 Mail: info@adeogroup.it – www.adeogroup.it Rev. 3 18. Firmware update The firmware update is not automatic and can only be carried out if you are in possession of the *.upf file provided through the Adeo Group's channels.
  • Page 17: Log

    Adeo Control SGD-C4-1 Adeo Group s.r.l. Via della Zarga n. 50 - 38015 LAVIS (TN) Manual Tel: +39 0461 248211 - Fax: +39 0461 245038 Mail: info@adeogroup.it – www.adeogroup.it Rev. 3 DIAGNOSTIC 19. Log Technical support can be provided remotely through the DIAGNOSTIC web page in the LOG section.

Table of Contents