Advertisement

Quick Links

OPERATION MANUAL
AIR CONDITIONER (Wall-Mounted type)
□ ASTH30CNTA
□ ASTH34CNTA
MODEL:
* Check the model name.
(Refer to the rating label.)
Before using this product, read these
instructions thoroughly and keep this
manual for future reference.
Contents
1. SAFETY PRECAUTIONS .......................................... 1
2. PREPARATION ......................................................... 2
2.1. Inserting batteries ............................................. 3
3. NAME OF PARTS ..................................................... 3
3.1. Indoor unit ........................................................ 3
3.2. Remote controller ............................................. 3
4. BASIC OPERATIONS ............................................... 5
5. AIRFLOW SETTINGS ............................................... 5
5.1. Fan speed setting ............................................. 5
5.2. Airflow direction setting .................................... 5
6. TIMER OPERATIONS ............................................... 5
6.1. On timer or Off timer ......................................... 6
6.2. Program timer ................................................... 6
6.3. Sleep timer ...................................................... 6
7. ENERGY SAVING OPERATIONS ............................ 6
7.1. Economy operation .......................................... 6
7.2. Fan control for energy saving ........................... 6
7.3. Demand Response ........................................... 6
8. OTHER OPERATION ................................................ 7
8.1. Powerful operation ........................................... 7
9. SETTINGS ON INSTALLATION ................................ 7
10. CLEANING AND CARE ............................................. 7
11. GENERAL INFORMATION ....................................... 9
12. OPTIONAL PARTS ................................................... 9
12.1. Wired remote controller .................................... 9
13. TROUBLESHOOTING ............................................ 10
PART No. 9387081619-01
R32
REFRIGERANT
This Air Conditioner contains and
operates with refrigerant R32.
THIS PRODUCT MUST ONLY BE INSTALLED OR SERVICED
BY QUALIFIED PERSONNEL.
Refer to Commonwealth, State, Territory and local legislation,
regulations, codes, installation & operation manuals, before
the installation, maintenance or service of this product.
En-1

1. SAFETY PRECAUTIONS

To prevent personal injury or property damage, read this section
carefully before you use this product, and be sure to comply
with the following safety precautions.
Incorrect operation due to failure to follow the instructions may
cause harm or damage, the seriousness of which is classified
as follows:
WARNING
This mark warns of death or serious injury.
CAUTION
This mark warns of injury or damage to property.
This mark denotes an action that is PROHIBITED.
This mark denotes an action that is COMPULSORY.
Explanation of symbols displayed on the indoor unit or outdoor unit.
WARNING
This symbol shows that this product uses a low
burning velocity material. If the refrigerant is leaked
and exposed to an external ignition source, there is a
risk of fire.
CAUTION
This symbol shows that the operation manual should
be read carefully.
CAUTION
This symbol shows that a service personnel should
be handling this equipment with reference to the
installation manual.
CAUTION
This symbol shows that information is available such
as the operation manual or installation manual.
WARNING
• When installing this product to an unventilated area,
pay attention to prevent fire and explosion caused
by the stagnated gas in case of refrigerant leakage.
(For products which contain more than 1.842 kg
refrigerant.)
• This product contains no user-serviceable parts.
Always consult authorized service personnel for
repairing, installation, and relocation of this product.
Improper installation or handling will cause leakage,
electric shock, or fire.
• In the event of a malfunction such as burning smell,
immediately stop operation of the air conditioner, and
disconnect all the power supply by turning off the
electrical breaker or disconnecting the power plug.
Then consult authorized service personnel.
• Take care not to damage the power supply cable.
If it is damaged, it should be replaced only by
authorized service personnel in order to avoid a
hazard.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AIRSTAGE ASTH30CNTA and is the answer not in the manual?

Questions and answers

Summary of Contents for Fujitsu AIRSTAGE ASTH30CNTA

  • Page 1: Table Of Contents

    OPERATION MANUAL 1. SAFETY PRECAUTIONS AIR CONDITIONER (Wall-Mounted type) To prevent personal injury or property damage, read this section carefully before you use this product, and be sure to comply with the following safety precautions. Incorrect operation due to failure to follow the instructions may cause harm or damage, the seriousness of which is classified as follows: WARNING...
  • Page 2: Preparation

    WARNING CAUTION • If a refrigerant leakage is suspected, all naked • The airflow direction and the room temperature should flames shall be removed or extinguished, and consult be carefully considered when you use this product in a authorized service personnel. room with infants, children, elderly or sick persons.
  • Page 3: Inserting Batteries

    Indoor unit accessories 3.1. Indoor unit Check that the following accessories are included. For Manual auto operation and Filter indicator reset (Refer to page 11.) Air cleaning filters Rating label Remote controller Remote controller Self-tapping screws Intake grille (*1) (Apple catechin filter, Front panel holder Ion deodorization filter)
  • Page 4 Signal transmitter : The setting must be done while the setting screen is displayed Aim at the signal receiver of the indoor unit properly. for each function. • Operating range is approximately 7 m. : The button is controllable only when the air conditioner is •...
  • Page 5: Basic Operations

    ■ Airflow direction range 4. BASIC OPERATIONS Up/down airflow direction Change by ■ 3 steps to start operation 1 ⇄ 2 ⇄ 3 ( ⇄ 4 ⇄ 5 ⇄ 6) Cooling, Dry 1. Press to start or stop the operation. 1 ⇄...
  • Page 6: On Timer Or Off Timer

    6.1. On timer or Off timer 7. ENERGY SAVING OPERATIONS 1. Select On timer or Off timer in step 1 of “Timer setting 7.1. Economy operation procedure.” 2. Each time you press , the time changes It saves more electricity than other operation modes by changing the set as follows: temperature to a moderate setting.
  • Page 7: Other Operation

    4. Press again. Contact your electricity supplier. The custom code will be set. No • Contact Fujitsu General (AUST.) PTY LIMITED. (Refer to The display will return to the original your warranty card.) display. • To change the air conditioner custom code, contact authorized •...
  • Page 8: Cleaning Air Filter

    4. Replace the air filters. Air cleaning filters Intake grille (Apple catechin filter, Ion deodorization filter) Align the sides of the air filter with the panel, and push in fully. Make sure to the two lower tabs are returned to their holes in the indoor unit properly.
  • Page 9: General Information

    Removing and installing intake grille 11. GENERAL INFORMATION ■ Removing intake grille ■ Auto-restart function 1. Open the intake grille. In event of power interruption such as a blackout, the air conditioner 2. While pressing the left and right mounting shafts outward stops once.
  • Page 10: Troubleshooting

    13. TROUBLESHOOTING Noise is heard. □ Is the unit operating, or immediate after stopping operation? In this case, refrigerant flowing sound may be heard. It may be WARNING particularly noticeable for 2-3 minutes after starting operation. □ Do you hear a slight squeaking sound during the operation? In the following events, immediately stop operation of This sound is produced by the minute expansion and contraction the air conditioner, and disconnect all the power supply...
  • Page 11 ■ Manual Auto operation and Filter indicator reset You can operate the air conditioner with on the indoor unit. Status Length of pressing down Mode or operation In operation More than 3 seconds Stop Stopping 2 seconds or less Filter indicator reset More than 3 seconds and Auto less than 10 seconds...

This manual is also suitable for:

Airstage asth34cnta

Table of Contents