04/13/2020 J. Blanchfield All Pages Revised 05/07/2018 D. Wilkinson All Pages Revised 02/12/2018 D. Wilkinson 1 (limitations) 04/25/2017 D. Wilkinson All Pages Revised 09/12/2016 D. Wilkinson Initial Revision 08/30/2016 D. Wilkinson 0107-0004 SunSpot 46-4000 Series Installation Rev_J.docx Page 2 of 10...
Switch Position Function Open Open Light OFF Open Closed Landing Pulse Landing Closed Open Light OFF Closed Closed Pulse Note: Refer to §5 Wiring Diagrams Table 2 Current consumption per input 0107-0004 SunSpot 46-4000 Series Installation Rev_J.docx Page 4 of 10...
Table 4 Installation Consult 14CFR, §43.13-1B for guidance on acceptable methods, techniques, and practices. Mount in approved bulb holder. For retrofit installation existing circuit breaker or fuse may 0107-0004 SunSpot 46-4000 Series Installation Rev_J.docx Page 5 of 10...
Page 6
Installation Procedures Reference the airframe manufacturer’s maintenance manual to complete the following steps If the AeroLEDs light(s) chosen for installation are higher wattage than the light(s) being removed, ensure the Electrical Load is not appreciably affected and ensure that all circuit components (circuit breaker, wire, switches, relays, etc., as applicable) are appropriate for the...
Page 7
Check for continuity in wiring and connections d. If wiring is verified, remove light and bench-check with appropriately sized power supply If above actions do not correct problem, contact AeroLEDs tech support at 1-208-850-3294 for a resolution. 0107-0004 SunSpot 46-4000 Series Installation Rev_J.docx Page 7 of 10...
Wiring Diagram for Single Sunspot with Pulse SYMBOLS TERMINAL PWR BUS (V+) Y EL PULSE CAP & STOW MASTER SLAVE FUSE TERMINAL GND BUS SWITCH Notes 1) Screw terminals are not polarity sensitiv e Figure 5-2 0107-0004 SunSpot 46-4000 Series Installation Rev_J.docx Page 8 of 10...
Page 9
TERMINAL Notes 1) Screw terminals are not polarity sensitiv e Figure 5-3 If lights are installed in close proximity (within two feet), install using an AeroLEDs sync circuit • AeroLEDs part number 00-8120 • Installation Guide 0017-0002 0107-0004 SunSpot 46-4000 Series Installation Rev_J.docx Page 9 of 10...
Page 10
CAP & STOW TERMINAL FUSE Y EL PULSE SWITCH MASTER SLAVE Notes TERMINAL 1) Screw terminals are not polarity sensitiv e TERMINAL Y EL PULSE MASTER SLAVE TERMINAL Figure 5-4 0107-0004 SunSpot 46-4000 Series Installation Rev_J.docx Page 10 of 10...