  • Page 1 LS - C 9 5 Smart lock User Manual www.locstar.com 400-8833-566 [Tuya(cat eye)] SHENZHEN LOCSTARTECHNOLOGYCO.,LTD Reserves the right to interpret this manual...
  • Page 2: Product Introduction

    I.Product introduction 1. Product performance parameter Bluetooth 5.0BLE Bluetooth standard Fingerprint head type Semiconductor fingerprint head 2.4GWiFi 802.11b/g/n Net work connection Fingerprint capacity 100 pieces(adjust according to the actual model) Supported mobil e Android 4.3/10s7.0 or later Recognition rate (FAR) <...
  • Page 3 4. 3D assembly drawing 1. C95 front panel components 6. Battery cover 11, self-tapping screw 4x25 4 pcs 2. C95 rear panel components 7. Rear cover plate + rubber pad 12, screw KM4x16 1 pcs 3. Single latch 8. Transfer column 13, screw KM4x5.5 2 Pcs 4.
  • Page 4 2. Installation tool (for reference only) 4. hammer 5. bit 1.manual electric drill 2.pencil 3.tape ruler 7.angle ruler 6.hacksaw 8. screwdriver 10.chisel 9.Cutter 3. Hole size diagram (for reference only) 26.5 5. Installation precautions ① ③ ④ ② In order to ensure successful Wearing eye protection In order to prevent unnecessary damage Select correct screw tool...
  • Page 5 3. Install the deadbolt on the door。 4. Hold the front body to the door, and cable through the door hole。 Bolt must be in retracted(unlocked) Bolt must be in retracted(unlocked) position.and TOP Word UP position. and Key piece vertical 5.
  • Page 6: Function And Operation

    III.Function and operation 3.1 Restoring Factory Settings 3.1.1. Hold on the RESET Clear button on the rear panel for 5S. voice will remind you to put in password, enter in "000#", will be restored successfully. Reset button 3. 1 . 2 . The factory default password is 12 3 4 5 6 , all fi ngerprint, password, card register clear.
  • Page 7 Door lock function operation extension map C95 intelligent door lock operation map 1.Add Administator information 1. Administator Settings 2.Delete Administator information 1.Add user information 2. Users settings 2.Add temporary user information 3.Delete user infor mation 1. Auto lock mode on 1.
  • Page 8 3.5 Initial state The factory engineering password is "123456" and can open the door. After entering the administrator information, the engineering password "123456" will be automatically deleted. 3.7 General operation rules For the first use, you need to add a set of management passwords, and the initial verification password is "123456" Verify the management password Enter a new management password The "#"...
  • Page 9 1.Administrator user management Enter the 1. Add an user Press 2 Press 3 2.User management Administrator deleted fingerprint/password/- 2. Add a temporary user 3. Door lock settings successfully card you want to delete 3. Delete a user 4. Restore factory settings 3.13 Function Settings Press 3 to enter the "Door Lock Settings"...
  • Page 10 (5) Vacation mode setting Enter the function setting menu and press 5 "Holiday mode setting" to set the door lock to holiday mode. Voice broadcast: "1,Vacation mode on 2, Vacation mode off". 1. Auto lock setting 2. Auto locking duration setting Press 5 1.
  • Page 11 3.18 Restore factory settings (1) Enter the door lock management menu, press 4 "Restore factory settings" to restore the lock to the factory state, and restore the administrator password to 123456 1.Administrator user management Press 4 2. User management Confirm—Press the # key 3.Door lock settings Exit—Press another key 4.
  • Page 12: Warranty Card

    Warranty Card 1. The manual and warranty card are included in the factory default packaging for each product. After installation, please fill in the warranty card and keep it properly as the warranty certificate. 2. Full grantee: 1 year 3. The following are not covered by the warranty: A.
  • Page 13 FCC Radiation Exposure Statement: This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator & your body. FCC Warning This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference...
  • Page 14 particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: —Reorient or relocate the receiving antenna.