NEO HS2016 / HS2032 / HS2064 / HS2128 v1.3
The NEO has several programming options to help reduce the electronic changes on the
HS2LCD keypads during normal daily activities. For example, using Bypass Group to
bypass specific zones, remove Open Zone Scrolling and turn off the Keypad Backlighting.
Panel Programming:
[ ] = NEO Panel Section
{ } = NEO Subsection
/ / = NEO Sub-Subsection / Double Flashing ~ Red Lock light in programming /
( ) = Data
Section [860] Verify the keypad supervisory slot number for each keypad as needed.
➢ Tech Tip: The keypad slot number can be viewed in Section [860] at
the desired keypad. Add this number to '860' for the desired
keypad programming section.
Section [861 - 876] Specific keypad programming options for Keypad 1 – 16.
➢ Tech Tip: Each keypad in the NEO has its own programming section
which can be accessed in programming from any keypad.
Section [861] = Keypad #1
Section [862] = Keypad #2
Section [876] = Keypad #16
Basic Setup:
1) Turn off 'Open Zone Auto Scroll' for each keypad as needed:
Section [861 – 876] {022} Option 8 ~ Auto Scroll Open Zones = 'N'
2) Program a function key for 'Recall Bypass Group': (e.g., 'Exit' key)
Section [861 – 876] {005} (29) Bypass Group Recall
➢ Tech Tip: The Function Keys for each keypad can be customized as needed.
Religious Observances
/ Solid ~ Red Lock light in programming /
/ Single Flashing ~ Red Lock light in programming /
/ Solid ~ Green Check light in programming /
•
•
•