  • Page 1 NO:2020.04 DZ158-125 Series Moulded Case Circuit Breaker User Instruction Standard: IEC/EN 60947-2...
  • Page 2: Safety Warning

    Safety Warning Installation in any damp, condensed-phase environment with inflammable and explosive gas is forbidden. It is strictly prohibited to operate the product with wet hands. You are prohibited from touching the conductive part when the product is operating. It is strictly prohibited to test the performance of the product by the direct contact of the hot wire against the grounding device or the direct short circuit of the hot wire and the neutral wire.
  • Page 3: Purpose Of Use

    Purpose of Use The DZ158-125 series moulded case circuit breakers are applicable to circuits with frequency of AC 50/60 Hz, rated voltage up to 240/415 V and rated current up to 125 A. They provide overload and short circuit protection, and can also be used for infrequent switching of the circuit under normal circumstances.
  • Page 4: Installation

    Installation 1. Outline and installation dimensions Unit:mm -1.40 78.5 Multipolar -1.40 -1.20 73.5 Unipolar -0.74 -1.20 49.5±0.31 -0.52 65.5±0.37 2. On-off indication Green O OFF l ON...
  • Page 5 3. Installation ② ① ④ ③ TH35-7.5 type mounting rail 4. Disassembly ② ① ③ 5. Wiring: copper wires only Table 2 Copper wire cross-sectional area Rated current I Copper wire cross-sectional area S (mm )
  • Page 6: Maintenance

    14.5mm 50mm Wiring torque 3.5N·m 14.5mm 50mm 20mm 50mm 20mm 50mm Maintenance 1、Check the circuit breaker on a regular basis during operation; 2、After the circuit breaker cuts off the overload or short-circuit current, the fault should be eliminated before closing the circuit breaker. Table 3 Analysis and troubleshooting of common faults Symptoms Cause analysis...
  • Page 7: Environmental Protection

    QC PASS DZ158-125 Series Moulded Case Circuit Breaker IEC/EN 60947-2 Check 12 Test date: Please see The packing ZHEJIANG CHINT ELECTRICS CO.,LTD.