Care 700 Series Toilet S-Trap Raised Height Installation and Maintenance Instructions CARE1546-RH CARE700WSC-RH CARE700GSC-RH technical data Working Pressure Range Min 50 kPa Max 500 kPa Inlet Connection 1/2” BSP (DN15) Water Inlet Connection Method Bottom inlet DN100 DWV PVC Pan Collar Outlet Connection Enware products are to be installed in accordance with the Plumbing Code of Australia (PCA) and AS/NZS3500.
installation 1. Determine Set Out For The Toilet Pan Determine location and set out for the toilet. Prepare waste outlet point according to one of the setout dimensions shown below Connection to be used is a 100mm DWV Pan Collar. Institutional / Health Set Out Set out typical for hospitals which allows for substantial air circulation and free coving Pan outlet...
Page 6
2. Determine Water Inlet Point The water connection to the cistern inlet is a 1/2" BSP male, bottom inlet. Looking from the front of the pan, it is located on the right hand side, on the bottom of cistern. Install a cistern tap in the vicinity. 3.
Page 7
SILICONE EN 15651-3. Class XS1 Ø5mm Fixing With Silicone Sealant: Determine if this method of fixing to the floor would be suitable according to the site risk assessment. This method of fixing is only suitable for tiled or similar hard floor surfaces. It is not suitable for vinyl floors, or for toilets with support arms.
Page 8
Fixing With Pan Screws: Determine if using pan screws would be appropriate according to the type and strength of the floor material, and the site risk assessment, taking into account the thickness of floor surface Base level and mortar bed, the distance to structural concrete slab, and the of pan impact to waterproofing membrane.
Page 9
Fixing With Floor Mounting Bracket: (CARE-WCFFP Floor Mounting Bracket sold separately.) On Concrete Slab / Floor Before Waterproofing: 1. Position the bracket on the floor according to layout template. (See diagram below, and CARE-WCFFP bracket installation instructions for more details.) 2.
Page 10
EN 15651-3. Class XS1 Ø5mm Installing the Pan: WC pan should be bedded with silicone sealant. Ensure the floor surface and bottom surface of pan are clean and dry, free of dust, moisture and grease. Place pan into position. Mark the profile of the foot of pan on the floor and remove pan.
5. Water Inlet Connection Flush the water supply line to ensure the line is clear, and connect water supply to the inlet connection of the cistern. The inlet connection is flexible. Hold the inlet thread on the hex with a spanner when making the thread connection.
Page 12
6. Install Rear Cover After pan is levelled, water supply and waste are connected, and the pan is tested and visually inspected for any leaks, install the rear cover to plug the inspection hole. Use the round cover provided. Discard flat cover. Apply silicone sealant inside and around the rear cover to create a thorough seal between the rear cover, pan and floor.
Page 13
access to cistern internal components To access the internal components of the cistern, use a slotted screw driver to lever the full flush button out, and unscrew the middle fixing bolt. Next, unscrew the cistern fixing screws using a T25 Torx key, and lift the ceramic shroud off the pan. Torx 25 Klick Klik...
Page 20
maintenance CLEANING • WC units have a glazed surface. Glazed surfaces are easy to keep clean and are resistant against most chemicals. • Clean bowl regularly. • Clean external surfaces regularly with a dry, soft cloth or a sponge. Alternatively clean with a soft damp cloth using only mild liquid detergent or soap and water, and wipe dry with a cloth.
troubleshooting PROBLEM CAUSE RECTIFICATION Toilet not flushing away Flush volume too low Increase flush volume Offset pan collars are used Do not use offset pan collars Drain blockages that can impede outlet flow Water constantly runs Cistern fill level is too high Adjust fill level on inlet valve into bowl to lower the water level...