Watts Enware Care 700 Series Installation And Maintenance Instructions Manual
Watts Enware Care 700 Series Installation And Maintenance Instructions Manual

Watts Enware Care 700 Series Installation And Maintenance Instructions Manual

Toilet s-trap raised height
Hide thumbs Also See for Enware Care 700 Series:

Advertisement

Quick Links

Care 700 Series Toilet S-Trap Raised Height
Installation and Maintenance Instructions
CARE1546-RH
CARE700WSC-RH
CARE700GSC-RH
technical data
Working Pressure Range
Inlet Connection
Water Inlet Connection Method
Outlet Connection
Enware products are to be installed in accordance with the Plumbing Code of Australia (PCA) and AS/NZS3500.
Installations not complying with PCA and AS/NZS 3500 may void the product and performance warranty provisions.
Reference should also be made to the Australasian Health Facility Guidelines (AHFG), ABCB and Local Government
regulations when considering the choice of, and the installation of these products.
This product must be installed and commissioned by a qualified plumber.
For use with potable water only.
NOTE: Enware Australia advises:
1. Due to ongoing Research and Development, specifications may change without notice.
2. Component specifications may change on some export models.
I00635_08 Apr 2025
1300 369 273 | info@enware.com.au | enware.com.au
Min 50 kPa
Max 500 kPa
1/2" BSP (DN15)
Bottom inlet
DN100 DWV PVC Pan Collar

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Enware Care 700 Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Watts Enware Care 700 Series

  • Page 1 Care 700 Series Toilet S-Trap Raised Height Installation and Maintenance Instructions CARE1546-RH CARE700WSC-RH CARE700GSC-RH technical data Working Pressure Range Min 50 kPa Max 500 kPa Inlet Connection 1/2” BSP (DN15) Water Inlet Connection Method Bottom inlet DN100 DWV PVC Pan Collar Outlet Connection Enware products are to be installed in accordance with the Plumbing Code of Australia (PCA) and AS/NZS3500.
  • Page 2: Product Description

    product description CARE1546-RH CARE700WSC-RH Bottom Inlet 1/2” BSP Male FRONT VIEW www.enware.com.au Page 2 © Enware Pty Ltd...
  • Page 3: Product Contents

    PRODUCT CONTENTS Toilet Rear Cover Pan Screws x 4 Soft Close Toilet Seat [For CARE700WSC-RH model] Care Toilet Seat [OPTIONAL] Support Arms [OPTIONAL] Floor Fixing Bracket [OPTIONAL] www.enware.com.au Page 3 © Enware Pty Ltd...
  • Page 4: Installation

    installation 1. Determine Set Out For The Toilet Pan Determine location and set out for the toilet. Prepare waste outlet point according to one of the setout dimensions shown below Connection to be used is a 100mm DWV Pan Collar. Institutional / Health Set Out Set out typical for hospitals which allows for substantial air circulation and free coving Pan outlet...
  • Page 5 Minimum Set Out The minimum to still allow air circulation behind the WC pan Minimum clearance Pan outlet 45° Corner Set Up MINIMUM MINIMUM MINIMUM MINIMUM Finished Wall Finished Wall With no arm support system With arm support system www.enware.com.au Page 5 ©...
  • Page 6 2. Determine Water Inlet Point The water connection to the cistern inlet is a 1/2" BSP male, bottom inlet. Looking from the front of the pan, it is located on the right hand side, on the bottom of cistern. Install a cistern tap in the vicinity. 3.
  • Page 7 SILICONE EN 15651-3. Class XS1 Ø5mm Fixing With Silicone Sealant: Determine if this method of fixing to the floor would be suitable according to the site risk assessment. This method of fixing is only suitable for tiled or similar hard floor surfaces. It is not suitable for vinyl floors, or for toilets with support arms.
  • Page 8 Fixing With Pan Screws: Determine if using pan screws would be appropriate according to the type and strength of the floor material, and the site risk assessment, taking into account the thickness of floor surface Base level and mortar bed, the distance to structural concrete slab, and the of pan impact to waterproofing membrane.
  • Page 9 Fixing With Floor Mounting Bracket: (CARE-WCFFP Floor Mounting Bracket sold separately.) On Concrete Slab / Floor Before Waterproofing: 1. Position the bracket on the floor according to layout template. (See diagram below, and CARE-WCFFP bracket installation instructions for more details.) 2.
  • Page 10 EN 15651-3. Class XS1 Ø5mm Installing the Pan: WC pan should be bedded with silicone sealant. Ensure the floor surface and bottom surface of pan are clean and dry, free of dust, moisture and grease. Place pan into position. Mark the profile of the foot of pan on the floor and remove pan.
  • Page 11: Water Inlet Connection

    5. Water Inlet Connection Flush the water supply line to ensure the line is clear, and connect water supply to the inlet connection of the cistern. The inlet connection is flexible. Hold the inlet thread on the hex with a spanner when making the thread connection.
  • Page 12 6. Install Rear Cover After pan is levelled, water supply and waste are connected, and the pan is tested and visually inspected for any leaks, install the rear cover to plug the inspection hole. Use the round cover provided. Discard flat cover. Apply silicone sealant inside and around the rear cover to create a thorough seal between the rear cover, pan and floor.
  • Page 13 access to cistern internal components To access the internal components of the cistern, use a slotted screw driver to lever the full flush button out, and unscrew the middle fixing bolt. Next, unscrew the cistern fixing screws using a T25 Torx key, and lift the ceramic shroud off the pan. Torx 25 Klick Klik...
  • Page 14: Maintenance

    maintenance Changing Outlet Washer 45° Click www.enware.com.au Page 14 © Enware Pty Ltd...
  • Page 15: Factory Settings

    Changing Flush Volume Factory settings 4 = 2,5 liter 13 = 4 liter 4 liter = 210 mm 45° 13 = 4 liter 6 liter = 230 mm 1 = 6 liter www.enware.com.au Page 15 © Enware Pty Ltd...
  • Page 16 4 = 2,5 liter 6 = 3 liter Klick Klik Cvak www.enware.com.au Page 16 © Enware Pty Ltd...
  • Page 17 Servicing Inlet Valve 45° www.enware.com.au Page 17 © Enware Pty Ltd...
  • Page 18 45° 45° www.enware.com.au Page 18 © Enware Pty Ltd...
  • Page 19 Reinstalling Cistern Cover and Flush Button Click Klick Klik Cvak www.enware.com.au Page 19 © Enware Pty Ltd...
  • Page 20 maintenance CLEANING • WC units have a glazed surface. Glazed surfaces are easy to keep clean and are resistant against most chemicals. • Clean bowl regularly. • Clean external surfaces regularly with a dry, soft cloth or a sponge. Alternatively clean with a soft damp cloth using only mild liquid detergent or soap and water, and wipe dry with a cloth.
  • Page 21: Troubleshooting

    troubleshooting PROBLEM CAUSE RECTIFICATION Toilet not flushing away Flush volume too low Increase flush volume Offset pan collars are used Do not use offset pan collars Drain blockages that can impede outlet flow Water constantly runs Cistern fill level is too high Adjust fill level on inlet valve into bowl to lower the water level...
  • Page 22: Spare Parts

    spare parts DESCRIPTION PRODUCT CODE DESCRIPTION PRODUCT CODE Complete inner tank CARE-S001 21 Soft close damper for CARE-S025 CARE-S023 seat Cistern housing CARE-S002 22 Buffers for CARE-S023 seat CARE-S026 Outlet flush valve CARE-S003 23 Rear cover - round CARE-S011 Inlet fill valve CARE-S004 25 Floor mounting bracket CARE-WCFFP...
  • Page 23: Product Warranty Statement

    - WATTS AUSTRALIA EFFECTIVE FROM 20 November 2023 3. Our responsibilities This Warranty Statement applies to products supplied by Australian Valve (a) In the event that the Supplier is reasonably satisfied that there is a Group Pty Ltd (ACN 068 227 270) (AVG) or Enware Pty Ltd (ACN 662...
  • Page 24 1300 369 273 info@enware.com.au enware.com.au...