1-channel module, sensor signal cond., x1, x10, x100 gain, ac/dc (60 pages)
Summary of Contents for PCB Piezotronics M242A01
Page 1
Model M242A01 Uniaxial Charge Strain Sensor Installation and Operating Manual For assistance with the operation of this product, contact PCB Piezotronics, Inc. Toll-free: 800-828-8840 24-hour SensorLine: 716-684-0001 Fax: 716-684-0987 E-mail: info@pcb.com Web: www.pcb.com...
Page 2
Assistance is needed to safely operate equipment PCB Piezotronics is an ISO-9001 certified company whose Damage is visible or suspected calibration services are accredited by A2LA to ISO/IEC Equipment fails or malfunctions 17025, with full traceability to SI through N.I.S.T.
Page 3
CAUTION Refers to hazards that could damage the instrument. NOTE Indicates tips, recommendations and important information. The notes simplify processes and contain additional information on particular operating steps. The following symbols may be found on the equipment described in this manual: This symbol on the unit indicates that high voltage may be present.
Page 5
Component Name Hazardous Substances Lead (Pb) Mercury (Hg) Cadmium (Cd) Chromium VI Polybrominated Polybrominated Compounds Biphenyls (PBB) Diphenyl Ethers (Cr(VI)) (PBDE) Housing PCB Board Electrical Connectors Piezoelectric Crystals Epoxy Teflon Electronics Thick Film Substrate Wires Cables Plastic Solder Copper Alloy/Brass This table is prepared in accordance with the provisions of SJ/T 11364.
Page 6
CHARGE MODE QUARTZ STRAIN SENSOR OPERATION MANUAL 1.0 INTRODUCTION A positive picocoulomb output (+pC) indicates that the PCB Charge Mode Quartz Strain Sensors incorporate structure being monitored is being subjected to a tensile force piezoelectric quartz sensing crystals that respond to a in the sensor mounting area and can also be resolved in units longitudinal change in distance.
Page 7
CHARGE MODE QUARTZ STRAIN SENSOR OPERATION MANUAL directly connected. It is recommended to use a source follower as close as possible to the charge output sensor. Driving long cables in a charge mode system is not suggested due to the induced noise. 5.0 POLARITY Extension of the mounting area on a charge mode strain sensor produce a positive output.
Page 8
CHARGE MODE QUARTZ STRAIN SENSOR OPERATION MANUAL 8.0 CALIBRATION Calibration procedures follow accepted guidelines recommended by ANSI (American National Standards Institute), ISA (Instrument Society of America), and ISO (International Organization for Standardization). These standards provide the establishment and management of complete calibration systems, thus controlling the accuracy of a sensor’s specifications by controlling measuring and test equipment accuracy.
Page 9
PROBLEM: Improper Sensor Sensitivity POSSIBLE CAUSE: SOLUTION: Improper XDCR sensitivity dial setting Ensure dial is adjusted and locked into proper setting Faulty sensor Call factory for service ICP is a registered trademark of PCB Piezotronics MANUAL NUMBER: 27883 MANUAL REVISION: NR ECN NUMBER:...
Page 11
PCB Piezotronics Inc. claims proprietary rights in REVISIONS the information disclosed hereon. Neither it nor any reproduction thereof will be disclosed to others DESCRIPTION without the written consent of PCB Piezotronics Inc. CHANGED TORQUE INSTRUCTION FROM 86 TO 89 IN-LBS 47189 ELECTRICAL CONNECTOR 10-32 UNF-2A .67 [17.0]...