Elite
Salter AIRE
Compressor
Instruction Manual
Part No: 8350-1 / 8352-1 / 8353-1
Elite
Thank you for selecting the Salter AIRE
Compressor. Salter Labs is an innovative, industry-
leading manufacturer of respiratory
care devices. Please contact your local Salter Labs
dealer for information about additional products.
.
SAVE THESE INSTRUCTIONS
READ ALL INSTRUCTIONS BEFORE USE.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AIRE Elite 8350-1 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Salter Labs AIRE Elite 8350-1

  • Page 1 Thank you for selecting the Salter AIRE Compressor. Salter Labs is an innovative, industry- leading manufacturer of respiratory care devices. Please contact your local Salter Labs dealer for information about additional products. SAVE THESE INSTRUCTIONS READ ALL INSTRUCTIONS BEFORE USE.
  • Page 2: Important Safeguards

    1. Important Safeguards NOTE, CAUTION, WARNING, AND SYMBOLS: Important information is highlighted by using the following: NOTE Indicates information that user should pay special attention to. CAUTION Indicates correct operating or maintenance procedures in order to prevent damage to or destruction of the equipment or other property.
  • Page 3 Symbols: Off, disconnection from the mains On, connection to the mains Alternating Current (AC) ~ IP2X Protected against solid foreign objects having a diameter of 12.5 mm and greater. No protection against vertically falling water drops. Keep dry! Attention Class II Refer to instruction manual/ booklet “BF”...
  • Page 4: Intended Use

    13. Never drop or insert any object into any opening or hose. 14. No modification of this equipment is allowed. 15. Do not modify this equipment without authorization of the manufacturer. 16. If this equipment is modified, appropriate inspection and testing must be conducted to ensure continued safe use of the equipment.
  • Page 5: Product Description

    for inhalation by the patients. Indications for therapy include asthma, chronic bronchitis, infection of the upper respiratory tract, chronic obstructive pulmonary disease (COPD) and other respiratory disorders in accordance with a medical doctor’s prescription. Except the usage mentioned above, please do not use this product for any other purpose. This device can be used with adults or pediatric patients under physician’s prescription.
  • Page 6: Safety Overload

    outlet connector. Assemble the nebulizer cup and add indicated medication to the nebulizer’s cup before use. Attach the other end of the tubing into the air-inlet connector founded at the bottom of the nebulizer cup. Elite Turn on the Salter AIRE Compressor by pressing the power switch to the I (ON) position and begin treatment.
  • Page 7: Filter Change

    Salter Labs ® authorized service representative. There are no serviceable parts inside the unit. Contact your Salter Labs dealer or authorized service center if your unit needs repair. WARNING Do not tamper with or attempt to repair the device.
  • Page 8: Specifications

    consult the Troubleshooting guide below. If the problem persists, consult your equipment provider. Problem Cause and Solution • Check if plug is properly fit into an Device doesn’t appropriate electrical outlet. operate • When device has been run continuously for over 30 minutes right before using, an auto shut down may activate by built-in thermal protector, cool down device for 30 minutes...
  • Page 9: Appendix A: Emc Information

    8906 Nebulizer with Pediatric Mask 8924 Nebulizer with Adult Mask 12. Appendix A: EMC Information Guidance and Manufacturer’s Declaration- Electromagnetic Emissions: This device is intended for use in the electromagnetic environment specified below. The user of this device should make sure it is used in such an environment. Emissions Electromagnetic Environment- Compliance...
  • Page 10 the relative humidity should be at least 30%. ±2kV for ±2kV for Electrical fast power Mains power quality power supply transient/ supply line should be that of a line burst ±1kV for typical commercial or ±1kV for IEC61000-4-4 input/out hospital environment. input/out line line ±...
  • Page 11 Recommended separation distances between portable and mobile RF communications equipment and this device: This device is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled. The customer or the user of this device can help prevent electromagnetic interference by maintaining a minimum distance between portable and mobile RF communications equipment (transmitters) and this device as recommended...
  • Page 12 Guidance and Manufacturer’s Declaration - Electromagnetic Immunity: This device is intended for use in the electromagnetic environment specified below. The user of this device should make sure it is used in such an environment. Immunity IEC60601 Compliance Electromagnetic Environment- Test test level Guidance Portable and mobile RF...
  • Page 13 Manufacturer’s declaration-electromagnetic immunity Test specifications for ENCLOSURE PORT IMMUNITY to RF wireless communications equipment The 9R-029003(8353-1) is intended for use in the electromagnetic environment (for home healthcare) specified below. The customer or the user of the 9R-029003(8353-1) should assure that it is used in such an environment. Pulse 380 –...
  • Page 14 30 Spur Drive 30 Spur Drive El Paso, TX, 79906 USA El Paso, TX, 79906 USA Phone: 1-800-421-0024, 1-800-235-4203 Toll-Free Fax: 1-800-628-4690 E-mail: customercare@salterlabs.com www.salterlabs.com 2797 Authorized Representative in the E.U.: MT Promedt Consulting GmbH Altenhofstrasse 80 D-66386 St. Ingbert, Germany NOTE Consult distributor(s) or EU representative(s) for additional technical documents.