Advertisement

Quick Links

User Manual
X
Probe B12
ORAYA
Version: 1.0.2

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the XORAYA Probe B12 and is the answer not in the manual?

Questions and answers

Summary of Contents for X2E XORAYA Probe B12

  • Page 1 User Manual Probe B12 ORAYA Version: 1.0.2...
  • Page 2 This user manual is copyrighted; all customary rights reserved. Reproduction of this manual, even in part, is only allowed with permission of X2E GmbH. Offenders shall be liable to pay compensation and may be subject to prosecution. All product names and trademarks used in this manual are the property of their respective owners.
  • Page 3: Table Of Contents

    Pictograms ....................7 1.4.1 Meaning of warnings..............7 1.4.2 Structure of warnings ..............8 X2E-Wiki ....................8 Safety and warranty ....................... 9 Intended use ..................... 9 Safety label on the device ................ 10 General safety instructions ..............10 Product liability ..................13 Terms of use ...................
  • Page 4 ANUAL ORAYA ROBE ABLE OF CONTENTS Cleaning ....................39 Repair ..................... 40 Storage, transport and disposal .................. 41 Storage ....................41 Transport ....................41 Disposal ....................41 Appendix............................ 43 Technical data ..................43 Pin assignments ..................44 8.2.1 1000Base-T1 (x12) ..............44 8.2.2 12V/Trigger/Wake ..............
  • Page 5: Introduction

    ANUAL ORAYA ROBE NTRODUCTION Introduction About this user manual  Read this user manual completely before using the X Probe B12 ORAYA for the first time.  Please consider this user manual as part of the product and make sure it is easily accessible.
  • Page 6: Validity Of The User Manual

    ANUAL ORAYA ROBE NTRODUCTION Validity of the user manual This user manual applies to X2E’s dataloggers of the X Probe B12 ORAYA series. The exact type specifications can be found on the nameplate. (➔ Identification) The following instructions are key to operate the Probe B12 and must be strictly observed under all circumstances.
  • Page 7: Pictograms

    ANUAL ORAYA ROBE NTRODUCTION Pictograms This manual uses pictograms to highlight and ensure faster recognition of important or especially useful information. Warning: These types of symbols indicate warnings that must be observed. The following subsections contain a description of the basic structure and relevance of different warning levels.
  • Page 8: Structure Of Warnings

    ▪ Latest firmware ▪ Latest license file ▪ For access details, please send an email stating your contact data to wiki@x2e.de. We will send you the appropriate access data. You may request your access details at any time if necessary.
  • Page 9: Safety And Warranty

    Upon measuring, safety regulations of the professional associations must be observed. Please contact an expert or the service of X2E GmbH when in doubt about the operation, safety, or connection of the Probe B12. Intended use The Probe B12 is used for real-time acquisition of data communication in automotive bus systems.
  • Page 10: Safety Label On The Device

    ANUAL ORAYA ROBE AFETY AND WARRANTY Safety label on the device You find the following safety label on the Probe B12 top side: Burning hazard due to hot surfaces Continuous operation can strongly heat up the Probe B12. As a result, it can burn the skin on the hands when touching it.
  • Page 11 ANUAL ORAYA ROBE AFETY AND WARRANTY Device damage due to short circuit Bent connector pins pose a short circuit risk. This can lead to abnormal behavior or destruction of the Probe B12. CAUTION Likewise, devices connected to the measurement setup may be also compromised.
  • Page 12 CAUTION  Never open the Probe B12.  Contact X2E GmbH should maintenance and repairs be required. Device damage due to penetration of dust or liquids Dust or moisture inside the Probe B12 may cause abnormal behavior or destruction of the device.
  • Page 13: Product Liability

    Terms of use If the installation of the Probe B12 in a vehicle is intended for operation on public roads, the user and the X2E GmbH must jointly perform a risk analysis beforehand. This analysis must consider the specific installation requirements and the valid factory standards at the user's site.
  • Page 14: Warranty

    The warranty also excludes damages arising from improper handling. X2E GmbH guarantees that the media on which the software is located are free of material errors under normal operating conditions. Users can return any defective or materially erroneous media to X2E GmbH within a period of 30 days from date of original purchase.
  • Page 15 ANUAL ORAYA ROBE AFETY AND WARRANTY Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
  • Page 16: Product Description

    ANUAL ORAYA ROBE RODUCT DESCRIPTION Product description The X Probe B12 is a compact probe specially designed for recording ORAYA automotive Ethernet. It extends the existing interfaces of X ORAYA dataloggers and enables the use of measuring devices in close proximity to the source.
  • Page 17: Scope Of Delivery

    ANUAL ORAYA ROBE RODUCT DESCRIPTION Scope of delivery The following components are part of the delivery: Probe B12 ▪ ORAYA Power supply cable ▪ Software ▪ User manual ▪ The following accessories are optionally available: Labelling foil with color coding for the 1000Base-T1 ports ▪...
  • Page 18: Connections And Controls

    ANUAL ORAYA ROBE RODUCT DESCRIPTION Connections and controls The front side of the Probe B12 contains ports, buttons and LEDs for operation and elementary functions. The back side contains the log interfaces. Front side LAN Host ORAYA PROBE B12 ADE IN ERMANY 12V/Trigger/Wake Default...
  • Page 19 ANUAL ORAYA ROBE RODUCT DESCRIPTION General status LEDs (A): These LEDs indicate the operating status of the Probe B12. Color Meaning Info Yellow Probe B12 is DHCP server Flashes when restarting after the power supply was interrupted and the Probe B12 could not shut down safely Connect Green Connection between Probe B12 and X...
  • Page 20 − Connect the drive and the firmware is automatically updated. Generating the supportfile ▪ − The supportfile is a set of files that you can send to X2E support to help solve technical issues. − Create the folder xoraya_supportfile on the USB flash drive.
  • Page 21 ROBE RODUCT DESCRIPTION 1000BASE-T1 interfaces (J): These 12 log interfaces record automotive Ethernet data in the 100BASE-T1 or 1000BASE-T1 standard. Service interface (K): In case of errors, this interface is used as a debugging interface by the X2E support team.
  • Page 22: Commissioning

     Please contact X2E GmbH immediately should the delivery be incomplete or upon damaged components.  Do not put any defective component into operation. X2E GmbH can only accept your complaint and replace the affected component upon prompt notification. Keep original packaging Keep the original packaging and packing materials for later storage or further transport.
  • Page 23  Close all open programs.  Use the X Suite setup wizard from the supplied data medium. ORAYA  Download the latest version of the X Suite from the X2E-Wiki. ORAYA (➔ X2E-Wiki)  Start the setup wizard and follow the instructions.
  • Page 24: Oraya

    ANUAL ORAYA ROBE OMMISSIONING Connecting the Probe B12 to the measuring environment This section describes how to connect the Probe B12 to the measuring environment. Device damage due to incorrect connection sequence The incorrect connection sequence can lead to abnormal behavior or destruction of the Probe B12.
  • Page 25: Power Supply

    ANUAL ORAYA ROBE OMMISSIONING 4.5.2 Power supply This chapter describes the default connection to a DC power supply via the supplied power cable. If you use the optionally available power cable with AC adapter, please note the specifications on the adapter label. Electric shock due to improper connection of the power supply Introducing the 4-mm plugs of the supplied power cable...
  • Page 26 ANUAL ORAYA ROBE OMMISSIONING Continuous current of the DC power supply A 12 V DC power supply must deliver a continuous current of 2.5 A. Use a regulated power supply or a car battery and note the required voltage and current levels. Connection order: ...
  • Page 27: Connecting The Probe B12 To The Pc

    ANUAL ORAYA ROBE OMMISSIONING The Probe B12 is equipped with an intelligent energy management system that lowers power consumption to about 1 mA (at 12 V supply voltage) in sleep mode. The device goes into sleep mode via the following actions or under the following conditions: Pressing and holding the power button (E) for at least 2 seconds.
  • Page 28: Xoraya Suite

    ANUAL ORAYA ROBE ORAYA UITE Suite ORAYA This chapter describes the characteristic features for the configuration and operation of the probe. For a detailed description of all X Suite tools, ORAYA refer to the datalogger user manuals. Connecting  Connect the Probe B12 to sink and PC. (➔...
  • Page 29: Sink

     Set a custom Device The ID is used when recording to match the data with a device.  Select the Mode of the sink: Master.  Select the Protocol: XLP (X2E internal) or PLP.  Optionally, set a VLan...
  • Page 30 ANUAL ORAYA ROBE ORAYA UITE  For time synchronization, set the PTP settings (Precision Time Protocol): Setting Description Domain A unique value for sinks in this network to avoid conflicts Interface E.g. for the N4000: eth0.* for 4x LAN Host, eth1.* for Ethernet 10 Gbit Restrict to port...
  • Page 31: Probe

    Probe  Set a custom Device  Select the Protocol: XLP (X2E internal) or PLP.  As Target, set the network address and port of the sink. If a static network connection for the DLN communication is explicitly set in the sink, then enter this address (category DLN).
  • Page 32 ANUAL ORAYA ROBE ORAYA UITE  Set the PTP settings eth0 (LAN Host), eth1 (10 GbE) and Global click Apply for each: Setting Description Enable Enable PTP for this interface Domain Must be the same value as the sink Master/Slave This interface is Master Slave...
  • Page 33: Data Recording

    ANUAL ORAYA ROBE ORAYA UITE Data recording By default, the probe transfers the recorded log data to the sink, where all data of the current measurement received from all connected devices is collected. The data is then either transferred to the PC or directly saved on the storage medium of the sink.
  • Page 34: Probe

    ANUAL ORAYA ROBE ORAYA UITE 5.3.2 Probe Data recording can also be initiated via the probe.  Connect to the probe.  Click Start Probe logging (2).  The probe starts data recording (Logging LED lights up) and transfers log data to the sink. Alternative recording method Via button Start online logging...
  • Page 35: Statistics

    ANUAL ORAYA ROBE ORAYA UITE Statistics The X Suite allows separate monitoring of the sink itself and of all ORAYA connected probes. 5.4.1 System signals in online-logging tool 5.4.2 Statistic tool The assigned ID is used to differentiate devices. By clicking on the panel in the upper area, the statistics for this device are highlighted below.
  • Page 36: Firmware

    Probe B12 and possible troubleshooting. Release connection to logger Open SWU/XSWU file Start Probe logging Launch firmware update Perform firmware update:  Download the latest firmware version from the X2E-Wiki. (➔ X2E-Wiki)  Click Open SWU/XSWU file (3).  In the File...
  • Page 37 ANUAL ORAYA ROBE ORAYA UITE  Confirm the Probe B12 restart twice, if Ask before restart in the Option menu is activated.  Skip restoring the configuration in the Option menu is not activated, the tool tries to restore the last Probe B12 configuration. Reset software Repeat the firmware update: ...
  • Page 38: Maintenance

    Safety defects due to incorrect accessories and spare parts Accessories and spare parts that have not been recommended by X2E GmbH negatively affect the safety, CAUTION functionality and precision of the Probe B12. X2E GmbH shall assume no responsibility whatsoever or...
  • Page 39: Cleaning

    ANUAL ORAYA ROBE AINTENANCE Cleaning Device damage due to pollution Avoid any contamination in plugs and sockets to ensure a reliable contact. CAUTION  Keep the Probe B12 clean. Device damage due to penetration of dust or liquids Dust or moisture inside the Probe B12 may cause abnormal behavior or destruction of the device.
  • Page 40: Repair

     Clean the Probe B12. (➔ Cleaning)  Pack the Probe B12 safely in its original packaging.  Include the completed return form. You can download this form from the X2E Wiki or receive via email upon request to xoraya-return@x2e.de.
  • Page 41: Storage, Transport And Disposal

    Phone: +49 6349 99599 211 E-mail: sales@x2e.de If more than 10 devices are returned at the same time, X2E must be informed in advance by the customer via the above e-mail address. Old devices to be returned must be clearly marked by the customer with the...
  • Page 42 Deletion of personal data X2E expressly points out that the customer is responsible for deleting personal data on the devices to be disposed of. Meaning of the symbol on the device...
  • Page 43: Appendix

    ANUAL ORAYA ROBE PPENDIX Appendix Technical data Property Value Timestamp resolution 100 ns for all interfaces Operating ambient temperature -40 to +65 °C Operating air humidity 10 to 95 % (non-condensing) Supply voltage 12 V DC (temporarily from 6 to 32 V) Current consumption Max.
  • Page 44: Pin Assignments

    ANUAL ORAYA ROBE PPENDIX Pin assignments The following tables show the pin assignments of the Base-T1 interface and of the 12V/Trigger/Wake port. Figures show the external view of the Probe B12 contacts. 8.2.1 1000Base-T1 (x12) Function CH 2 P CH 2 N HARTING ix Industrial type A (x6) CH 1 P CH 1 N...
  • Page 46 X2E GmbH Grosse Ahlmuehle 19 76865 Rohrbach Germany Phone +49 6349 99599 200 E-mail xoraya@x2e.de Internet www.x2e.de Wiki wiki.x2e.de...

Table of Contents