Electro-Optics Technology EOT 1.5-5mm PbSe User Manual

Power detector

Advertisement

Quick Links

EOT 1.5-5µm PbSe POWER DETECTOR USER'S GUIDE
Thank you for purchasing your 1.5-5µm PbSe Power Detector from EOT. This user's guide will help answer
any questions you may have regarding the safe use and optimal operation of your Power Detector.
I.
1.5-5µm PbSe Power Detector Overview ....................................................................................................... 1
II. Operation of Your 1.5-5µm PbSe Power Detector .......................................................................................... 1
III. Troubleshooting ............................................................................................................................................... 2
IV. Drawings: 1.5-5µm PbSe Power Detectors ..................................................................................................... 3
V. Specifications: 1.5-5µm PbSe Power Detectors .............................................................................................. 4
VI. Schematics: 1.5-5µm PbSe Power Detectors .................................................................................................. 4
VII. Warranty Statement and Repair ..................................................................................................................... 4
VIII. Glossary of Terms ......................................................................................................................................... 5
I.

1.5-5µm PbSe Power Detector Overview

EOT's 1.5-5µm PbSe Large Area Power Detectors can be used to measure power from 1.5µm to 5.0µm,
has a selectable gain of either 2X or 100X, and an active area of 5mm x 5mm making alignment easy.
Based on a photoconductor, it responds more quickly and reaches a stable state more quickly than a
thermopile detector. Figure 1 below identifies the main elements of your Power Detector.
II.

Operation of Your 1.5-5µm PbSe Power Detector

A. Caution: Eye safety precautions must be followed when utilizing any equipment used in the vicinity
of laser beams. Laser beams may reflect from the surface of the detector or the optical mount and
caution must be exercised.
(231)935-4044 (800)697-6782 Fax: (231)935-4046 sales@eotech.com www.eotech.com

TABLE OF CONTENTS

Figure 1: EOT 1.5-5µm PbSe Large Area Power Detector
Gain
Switch
Sensor
Aperture
Electro-Optics Technology, Inc.
5835 Shugart Lane Traverse City, MI 49684
Power
Jack
Power
Switch
BNC
Connector
Page 1 of 6

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the EOT 1.5-5mm PbSe and is the answer not in the manual?

Questions and answers

Summary of Contents for Electro-Optics Technology EOT 1.5-5mm PbSe

  • Page 1: Table Of Contents

    A. Caution: Eye safety precautions must be followed when utilizing any equipment used in the vicinity of laser beams. Laser beams may reflect from the surface of the detector or the optical mount and caution must be exercised. Electro-Optics Technology, Inc. 5835 Shugart Lane Traverse City, MI 49684 (231)935-4044 (800)697-6782 Fax: (231)935-4046 sales@eotech.com www.eotech.com...
  • Page 2: Troubleshooting

    1. There are no user serviceable parts in this device. Opening the detector could result in a SHOCK HAZARD due to a high voltage bias circuit. Electro-Optics Technology, Inc. 5835 Shugart Lane Traverse City, MI 49684 (231)935-4044 (800)697-6782 Fax: (231)935-4046 sales@eotech.com www.eotech.com...
  • Page 3: Drawings: 1.5-5Μm Pbse Power Detectors

    1. Call EOT’s customer service and request an RMA number to return the device to EOT. DO NOT try to open the detector. Drawings: 1.5-5µm PbSe Power Detectors A. ET-6000 Dimensions: Electro-Optics Technology, Inc. 5835 Shugart Lane Traverse City, MI 49684 (231)935-4044 (800)697-6782 Fax: (231)935-4046 sales@eotech.com www.eotech.com Page 3 of 6...
  • Page 4: Specifications: 1.5-5Μm Pbse Power Detectors

    An optical chopper and lock-in amplifier are recommended for proper operation. Schematics: 1.5-5µm PbSe Power Detectors     VII. Warranty Statement and Repair Electro-Optics Technology, Inc. 5835 Shugart Lane Traverse City, MI 49684 (231)935-4044 (800)697-6782 Fax: (231)935-4046 sales@eotech.com www.eotech.com Page 4 of 6...
  • Page 5: Viii. Glossary Of Terms

    Service department will either issue an RMA for the device, or provide the customer with a procedure and authorize the customer to modify the device. All returns should reference the RMA number on the outside of the shipping container and should be sent to: Electro-Optics Technology, Inc. Attn: Sales/Customer Service 5835 Shugart Lane...
  • Page 6 Fall Time is the time taken for the amplitude of a pulse to decrease from a specified value to another specified value. A larger junction capacitance will slow the detector’s response time. Electro-Optics Technology, Inc. 5835 Shugart Lane Traverse City, MI 49684 (231)935-4044 (800)697-6782 Fax: (231)935-4046 sales@eotech.com www.eotech.com...

Table of Contents