Inhalt
1
Which hardware versions are available? ......................................................................... 2
2
How to setup IP-Communication in WINDOWS? ............................................................ 7
3
What terminal software is optimal for communication? .................................................... 8
4
What browser software is optimal for communication? .................................................... 9
5
How to exchange a PVR6 against the EV2D? ............................................................... 10
6
How to setup EV2D? ..................................................................................................... 12
7
How to change working parameter? .............................................................................. 13
8
How to change parameter for process ERROR detection? ........................................... 15
9
How to change Ethernet IP-setting? .............................................................................. 16
10 How to adapt the setting for ENABLE / DISABLE? ........................................................ 17
11 Three question marks „???" in communication and now? ............................................. 20
12 How is the wiring between PC and the EV2D via RS232? ............................................ 21
13 What is the „rep"-function and how to use it? ................................................................ 22
14 How to handle a FAULT? .............................................................................................. 25
15 What predefined valve code exist?................................................................................ 26
16 New amplifier with a FAULT? ........................................................................................ 28
17 How transmit a text-file with parameter settings? .......................................................... 28
18 How to get trace-data with WEB-server interface ? ....................................................... 30
19 The communication via Ethernet with "TeraTerm" break down? .................................... 32
20 How to setup EV2D-EC-EW first time? ......................................................................... 33
Pforte, Hartwig │ 23.11.2023
1 │ 34

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the EV2D and is the answer not in the manual?

Questions and answers

Summary of Contents for HAWE Hydraulik EV2D

  • Page 1: Table Of Contents

    10 How to adapt the setting for ENABLE / DISABLE? ............17 11 Three question marks „???“ in communication and now? ..........20 12 How is the wiring between PC and the EV2D via RS232? ..........21 13 What is the „rep“-function and how to use it? ..............22 14 How to handle a FAULT? ....................
  • Page 2: Which Hardware Versions Are Available

    1 Which hardware versions are available? Conventions for product name: EV2D Electronic Valveamplifier 2nd-Version Digital Analogic set value set value via EtherCAT Fieldbus-Interface Grundgerät (Base) with Erweiterung (Extension) EV2D-A-G to control one HAWE Proportional-Way-Valve. Pforte, Hartwig │ 23.11.2023 2 │ 34...
  • Page 3 EV2D-A-G to control two HAWE Proportional-Pressure-Reliefe-Valve. Pforte, Hartwig │ 23.11.2023 3 │ 34...
  • Page 4 EV2D-EC-G to control one HAWE Proportional-Way-Valve. EV2D-EC-G to control two HAWE Proportional-Pressure-Reliefe-Valve. Pforte, Hartwig │ 23.11.2023 4 │ 34...
  • Page 5 EV2D-A-EW to control one HAWE Proportional-Way-Valve and two HAWE Proportional Pressure-Reliefe-Valve. Pforte, Hartwig │ 23.11.2023 5 │ 34...
  • Page 6 EV2D-EC-EW to control one HAWE Proportional-Way-Valve and two HAWE Proportional Pressure-Reliefe-Valve. Pforte, Hartwig │ 23.11.2023 6 │ 34...
  • Page 7: How To Setup Ip-Communication In Windows

    2 How to setup IP-Communication in WINDOWS? do a right click on the network symbol select „network and internet settings“ select „change adapter settings“ inside the open folder mark „network connections“ and do a right click on „Ethernet“ inside the new window open „properies“ as result the following window should appear mark „internetprotocol version 4 (TCP/IPv4) open „properties“...
  • Page 8: What Terminal Software Is Optimal For Communication

    3 What terminal software is optimal for communication? The following description is for „TeraTerm“. „TeraTerm“ can communicate via TCP/IP. Attention: Before processing the steps below do settings according FAQ 2! 1st step: establish a new connection (Alt-N) 2nd step: setup the interface Settings: TCP/IP Host: 192.168.133.10...
  • Page 9: What Browser Software Is Optimal For Communication

    4 What browser software is optimal for communication? Mozilla can be an independent browser for all computer operating systems. Open the browser and enter the IP shown below. Save the page for later recalls in „favorites“. Using a browser allows to get information via the implemented WEB-Server. Pforte, Hartwig │...
  • Page 10: How To Exchange A Pvr6 Against The Ev2D

    5 How to exchange a PVR6 against the EV2D? Pforte, Hartwig │ 23.11.2023 10 │ 34...
  • Page 11 Pforte, Hartwig │ 23.11.2023 11 │ 34...
  • Page 12: How To Setup Ev2D

    The letter x y z w are place holder. To get the needed code please refer the MANUAL. As example: „loadpara 4 1 1 1<ENTER/RETURN>“ Wait until the EV2D show o.k.! 6. Enter „on<ENTER/RETURN>“ As result you get the screen below.
  • Page 13: How To Change Working Parameter

    5. Enter „rep<ENTER/RETURN>“ As result you get the screen shown below. The EV2D-x-EW print up to 8 signal values, the EV2D-x-G print up to 4 signal values until it will be stopped. To stop the continuously print process press <ENTER/RETURN>-key 6.
  • Page 14 The printed signals per print line do not fit for the example. So it‘s necessary to adapt the print values. According to the graphic above the input signal of the box is signal S1 and the output signal of the box is signal OG_S1. In step 7 the print signal FB1 is changed to OG_S1.
  • Page 15: How To Change Parameter For Process Error Detection

    This example describe the adaptation of error threshold values to supervise existing pressure sensors with 4-20mA output signal. Target is to check broken wire between EV2D and pressure sensor P1. The needed threshold value should be between 10 and 800 units.
  • Page 16: How To Change Ethernet Ip-Setting

    The optimal terminal software is „TeraTerm“. Setup the COM-port like shown below. The free COM-port depends on your configuration of the software operating system e.g. WINDOWS. First action is to check the actual status inside the EV2D. Follow the steps below. 1. Enter „off<ENTER/RETURN>“ Pforte, Hartwig │ 23.11.2023...
  • Page 17: How To Adapt The Setting For Enable / Disable

    2. Enter „Get_IPA1<ENTER/RETURN>“ 3. Enter „Get_SGW1<ENTER/RETURN>“ 4. Enter „Get_SNM1<ENTER/RETURN>“ 5. Enter „Get_PRT1<ENTER/RETURN>“ As result you get the screen shown below. Attention! Each segment of the IP-address must be entered in 3 digit! Example: 128 162 104 002 The xxx xxx xxx xxx are placeholder inside the command sequence below to represent the target digits of the new IP-address.
  • Page 18 In this operation mode some errors, coming from relay contacts, can be gated. Also test signals coming from the savety unit can be gated. To adapt the EV2D in this case the knowledge of the safety unit signals is necessary.
  • Page 19 Operation mode BA = 1: This operation mode gates test pulse up the width of 500µs. This works only if the space between 2 pulses is constant. You must know this distance between 2 pulses to setup the paramter Tc. Operation mode BA = 2: This operation mode is made to work together with laser light safety gates.
  • Page 20: Three Question Marks „???" In Communication And Now

    Enter „on<ENTER/RETURN>“ 11 Three question marks „???“ in communication and now? Inside the EV2D works a simple monitor software. That means each command including space and capitals must be entered exact. If the monitor do not „understand“ the entered code the response is three question maks „???“ .
  • Page 21: How Is The Wiring Between Pc And The Ev2D Via Rs232

    0701<ENTER> list the parameter of the logic box 01 located on page 07 12 How is the wiring between PC and the EV2D via RS232? Pining 1-X4: 2 – TxD 3 - GND 4 - RxD The best way to connect is to use a special adapter cable.
  • Page 22: What Is The „Rep"-Function And How To Use It

    13 What is the „rep“-function and how to use it? The command „rep“ stands for repeat and mean the continously listing of internal calculated values in up to eight columns. See example below. The „rep“-function work as a simple scope with manual start / stop. The time between two captured and listed lines is fix 100ms.
  • Page 23 This top position for the process connection is called repeat buffer. Depending of the used version of EV2D up to eight repeat buffer available. This repeat buffer counted from 0 to 7. Example for such a connection command (refer graphics in FAQ 7): enter „RP_S1 r 0<ENTER/RETURN“...
  • Page 24 The EV2D run already without any fault and the communication between the PC and the EV2D is established (refer FAQ 2 and FAQ 3). 1. Activate the Log…Function inside „TeraTerm“ 2. Define the file name and the place to store.
  • Page 25: How To Handle A Fault

    1-X6 the internal test routines run again (green LED blink 3 times). If the ERROR still occur the EV2D has to be replaced. One exception exist. If ERROR 11 pop up there is a mistake in your signal workflow.
  • Page 26: What Predefined Valve Code Exist

    15 What predefined valve code exist? Pforte, Hartwig │ 23.11.2023 26 │ 34...
  • Page 27 Pforte, Hartwig │ 23.11.2023 27 │ 34...
  • Page 28: New Amplifier With A Fault

    16 New amplifier with a FAULT? 1. Establish communication to the EV2D 2. Press <ENTER/RETURN>-key As result you get the screen shown below. 4. Enter „ERRO<ENTER/RETURN>“ to check the ERROR-code 5. Enter „para<ENTER/RETURN>“ to check the activated working parameter As result you get the screen shown below.
  • Page 29 4. Select the file to be transfered 5. Press button Open to proceed As result you get the screen shown below. (listing depends on the commands inside the file) 6. Check the result by using the command “pr” to get a parameter list or use the command “rep”...
  • Page 30: How To Get Trace-Data With Web-Server Interface

    18 How to get trace-data with WEB-server interface ? 1. Start your preferred BROWSER and enter the target IP (see below) As result you should see the START-screen. 2. Klick the button DLOG As result you should see the DLOG-screen. Pforte, Hartwig │...
  • Page 31 ATTENTION! As you see ENABLE is ON. It has to be DISABLE bevor reading the TRACE-DATA. 3. Press the button DUMP As result you should see the result area is filling the screen. It take some time. WAIT UNTIL THE BUTTON DUMP IS BACK! To check the DUMP has finished you can move the slider on the right side to the begin and end area.
  • Page 32: The Communication Via Ethernet With "Teraterm" Break Down

    4. Klick with your mouse inside the window data area 5. Select all data -> use key-combination Ctrl+a 6. copy the selected data -> use key-combination Ctrl+c 7. open a new text-file 8. paste all data -> use key-combination Ctrl+v 9.
  • Page 33: How To Setup Ev2D-Ec-Ew First Time

    20 How to setup EV2D-EC-EW first time? Test & Results: 1. DISABLE -24V at (1-X6.1 and 24V at 1-X5.1) – GND at (1-X6.4) EtherCAT & LVDT’s not connected -> -Result -> short flash of LED FAULT (red) -> LED 24V (green) blinking permanent -> ERRO...
  • Page 34 DISABLE -Result -> LED 24V (green) blinking permanent -> ERRO 0x0000 AND WARN 0x0000 4. DISABLE -EV2D is still energized -> TwinCAT PLC in RUN -Result -> LED 24V (green) static ON -> ERRO 0x0000 AND WARN 0x0000 ENABLE -EV2D is still energized -> TwinCAT PLC in RUN -Result ->...