Duo Corner - 2 Person Quadro Corner - 4 Person USER MANUAL Find the Digital Manual Online Product may vary slightly from the item pictured due to model upgrades. Read all instructions carefully before using this product. Retain this owner’s manual for future reference. NOTE: This manual should not be used to guide your purchasing decision.
I. IMPORTANT SAFETY INSTRUCTIONS For your safety, it is crucial to adhere strictly to the following precautions while using this product: 1. Ensure that children use the equipment under the supervision of an adult. Avoid playing with the equipment for safety reasons. 2.
II. INSTALLATION PROCEDURE a. Do not plug any other appliances into the outlet. b. Install the sauna on a completely level floor. c. Do not spray the exterior with water. If the floor is damp, install a floor separator to keep the sauna high and dry.
III. ASSEMBLY INSTRUCTION STEP 1. BOTTOM FLOOR ASSEMBLY Place the bottom board in the desired location of your sauna and identify the front and back sections. STEP 2. LEFT BACK PANEL ASSEMBLY Align the left back panel with the bottom board’s corresponding battens. Ensure they are in line. ASSEMBLY INSTRUCTIONS |...
Page 6
STEP 3. RIGHT BACK PANEL ASSEMBLY Align the right back panel with the corresponding battens on the bottom board, ensuring they are properly aligned. IMPORTANT: The buckle is attached to both back panels. After installing the right and left back panels, lock them securely to ensure they are firmly connected.
Page 7
Connect the inner wires to the bench heater securely, ensuring proper alignment and a firm connection. STEP 5. LEFT BENCH SUPPORT ASSEMBLY Place the left small seat bench vertically onto the bottom panel, then gently push it flat against the right support panel.
Page 8
STEP 6. INSTALL THE BENCH PANEL FOR LEFT BACK AND RIGHT BACK PANELS | ASSEMBLY INSTRUCTIONS...
Page 9
STEP 7. INSTALL THE LEFT SIDE PANEL Pick up the left side panel, align it with the floor battens and the left rear panel, ensuring they fit together properly. INSTALLATION: Use the inner locks to secure the panels together, as shown in the picture. STEP 8.
Page 10
STEP 9. INSTALL THE FRONT PANEL Install the front panel by positioning it correctly, aligning it with the floor cleats. Secure it to the left and right panels using the locking system. STEP 10. INSTALL THE TOP PANEL Raise the roof panel high enough to align it perfectly with the roof frame and cab panels. Ensure all cables are placed outside to allow sufficient space for the top panel installation.
Page 11
STEP 11. WIRE ASSEMBLY As you lower the internal top board into place, ensure that all the wires and connecting plugs mentioned above are guided through the corresponding holes in the top board. These wires will connect to the controller on the internal top board. Next, feed the power plugs for the speakers, temperature sensor, and control panel through the hole in the...
IV. CIRCUIT DIAGRAM OF THE ELECTRICAL BOX Overcurrent LIGHT LIGHT OXYGEN SPEAKER Protector Control Panel LED light 1-2-3 Speaker Temperature Sensor | CIRCUIT DIAGRAM OF THE ELECTRICAL BOX...
V. CONTROL PANEL OPERATION Controller Brief Description 1. ON/OFF Button: ON: When you plug the unit into the electrical outlet, the power indicator will flash. Press the ON/ OFF button to turn the sauna on immediately. The LCD will display the last used settings for both temperature and time.
Page 14
4. Fahrenheit/Celsius Settings: When adjusting the temperature, press both the [up] and [down] buttons simultaneously to toggle between Fahrenheit and Celsius. 5. Reading Light Control: In normal operation, press the light button once to turn the reading light on. Press it again to turn the light off.
Page 15
9. Bluetooth: - Press the button three times to enter Bluetooth mode. The screen will display "B-". After hearing a sound, search for the Bluetooth name on your mobile device to connect. - Once connected, you can play music from your mobile phone. Use the play/pause button to control playback.
VI. SAUNA OPERATION GUIDE 1. Precautions • Ensure all circuitry and plugs meet safety requirements. • Set the temperature and time to a comfortable level, typically 120°F for 30 minutes. • Drink a glass of water before using the sauna. •...
Page 17
3. Safety Precautions • Fire Hazard: To avoid the risk of fire, do not dry clothes or leave towels inside the sauna. • Burn & Shock Prevention : 1. Avoid touching or using metal tools on the net cover of the Carbon heater elements. 2.
The heater is broken Replace the heater with a new The heater’s lifespan has one of the same specifications decreased from frequent use Carbon heater is not Replace the fuse with one of the...
VIII. MAINTENANCE CLEANING: - Clean the faceplate using a damp towel. If necessary, use a small amount of hand soap mixed with warm water. - Clean the sauna room with a damp cotton towel and dry it with a clean, dry towel. - Do not use benzene, alcohol, or strong cleaning chemicals on the sauna, as they may damage the wood and its protective layer.
Any claim against this warranty must be made through your original place of purchase. Proof of purchase is required before a warranty claim may be processed. If you have purchased this product from the Official Lifespan Fitness website, please visit https://lifespanfitness.com.au/warranty-form For support outside of warranty, if you wish to purchase replacement parts or request a repair or service, please visit https://lifespanfitness.com.au/warranty-form and fill in our Repair/Service...